BACKGROUND: Nitrous oxide (N(2)O) is the oldest anesthetic in routine clinical use and its occupational exposure is under regulation by many countries. As studies are lacking to demonstrate the status of nitrous oxide levels in operating and recovery rooms of Iranian hospitals, we aimed to study its level in teaching hospitals of Tehran University of Medical Sciences.Entities:
Keywords: Environmental monitoring; Iran; Nitrous oxide occupational health; Ventilation
Year: 2011 PMID: 23113075 PMCID: PMC3481765
Source DB: PubMed Journal: Iran J Public Health ISSN: 2251-6085 Impact factor: 1.429
The frequency distribution of ventilation and scavenging systems status in operating and recovery rooms
|
| |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Operational | Not operational | Operational | Not connected to anesthetic machine | Not connected to outside vent | |||||
| Operating rooms[no. (%)] | 27(62.8) | 10(20.9) | 6(14) | 43(100) | 14(32.4) | 11(25.6) | 10(23.4) | 8(18.6) | 43(100) |
| Recovery rooms[no. (%)] | 5(41.7) | 1(8.3) | 6(50) | 12(100) | 0 | 0 | 0 | 12(100) | 12(100) |
| Total | 32(58) | 11(20) | 12(22) | 55(100) | 14(25.4) | 11(20) | 10(18.2) | 20(36.4) | 55(100) |
The shift-long exposure of operating and recovery room staffs to nitrous oxide (TWA/ppm)
| Rooms equipped with ventilation system, operational | 138.5±123.1 | 139.2±121.2 | 98.7±97.3 | 75.5±40.4 | < 0.001 | 1.83 |
| Rooms equipped with ventilation system, not operational | 326.8±277.7 | 188.1±74.0 | 216.8±149.0 | 96.6± 60.2 | < 0.001 | 3.38 |
| Rooms with no ventilation system | 440.0±129.1 | 399.4±116.9 | 367.7±88.1 | 109.4± 97.7 | < 0.001 | 4.02 |
TWA time weighted average
ANOVA