Inhaling nitrous oxide reduces the induction dose requirements of propofol.

J M Ng1, N C Hwang.   

Abstract

Inhaling nitrous oxide (N(2)O) before propofol induction appears to decrease propofol usage. To investigate the efficacy of N(2)O as a component of the drugs used to induce anesthesia, the effect of inhaling a N(2)O:oxygen (O(2)) mixture on the dose of propofol required to induce anesthesia was determined in a double-blinded manner. We randomized 117 unpremedicated patients scheduled for elective surgery into three groups. Group FN received 1 microg/kg fentanyl and breathed 4 L/min N(2)O + 2 L/min O(2). Group PN received placebo and breathed 4 L/min N(2)O + 2 L/min O(2). Group FO received 1 microg/kg fentanyl and breathed 6 L/min O(2). Propofol was infused at 20 mg/min after 1 min of gas mixture inhalation, and the infusion stopped when there was loss of response to verbal command. The mean (SD) propofol dose was 0.75 (0.30), 0.84 (0.26), and 1.33 (0.51) mg/kg, and the induction time 133 (57), 142 (47), and 226 (78) s for Groups FN, PN, and FO, respectively. We conclude that inhalation of 66% N(2)O in O(2) 1 min before the IV induction of anesthesia with propofol at 20 mg/min, reduces the induction dose of propofol by 44% and decreases the time required for the induction of anesthesia (P < 0.001).

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10781482     DOI: 10.1097/00000539-200005000-00040

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  4 in total

1.  Nitrous oxide can enhance the hypnotic effect, but not the suppression of spinal motor neuron excitability by propofol in humans.

Authors:  Manabu Kakinohana; Yuji Miyata; Hiroshi Tomiyama; Kazuhiro Sugahara
Journal:  J Anesth       Date:  2006       Impact factor: 2.078

2.  Effects of Inhaled Nitrous Oxide on the Induction Dose and Time Requirements of Propofol: A Prospective, Randomized, Double-blind Study.

Authors:  Kavita Jain; Surendra Kumar Sethi; Mamta Damor; Neena Jain
Journal:  Anesth Essays Res       Date:  2017 Jan-Mar

3.  Quantitative Assessment of Nitrous Oxide Levels in Room Air of Operation Theaters and Recovery Area: An Observational Study.

Authors:  G D Puri; Shyam C Meena; Vinayak Sinha; Amarjyoti Hazarika; Haseeb Hakkim; Ashish Sharma; Kamal Kajal; Neeti Dogra
Journal:  Indian J Occup Environ Med       Date:  2021-10-09

4.  Nitrous oxide levels in operating and recovery rooms of Iranian hospitals.

Authors:  Sh Sadigh Maroufi; Mj Gharavi; M Behnam; A Samadikuchaksaraei
Journal:  Iran J Public Health       Date:  2011-06-30       Impact factor: 1.429