Literature DB >> 23111610

Repeatability of Spectralis OCT measurements of macular thickness and volume in diabetic macular edema.

Oliver Comyn1, Ling Zhi Heng, Felicia Ikeji, Kanom Bibi, Philip G Hykin, James W Bainbridge, Praveen J Patel.   

Abstract

PURPOSE: We estimated coefficients of repeatability for Spectralis optical coherence tomography (OCT)-derived automated retinal thickness and volume measurements in subjects with center-involving diabetic macular edema (DME).
METHODS: A total of 50 eyes of 50 consecutive patients with center-involving DME underwent four consecutive "fast" volume scans at a single session using one OCT device operated by one of two experienced operators. Bland-Altman coefficients of repeatability (CR) were calculated for automated retinal thickness measurements in the nine Early Treatment of Diabetic Retinopathy Study (ETDRS) subfields, center point thickness, and total macular volume. Scans were evaluated for significant automated retinal boundary detection error and revised estimates for CR calculated with these scans excluded.
RESULTS: CR in the central subfield was 8.03 μm (95% confidence interval [CI] 7.70-8.35 μm). In other subfields, CR ranged from 6.54 to 18.25 μm. Scan sets from 13 subjects had significant boundary detection error; reanalysis with these excluded yielded a CR for the central subfield of 7.44 μm with CR for all other subfields <8 μm.
CONCLUSIONS: Retinal thickness measurements in subjects with DME obtained using Spectralis OCT are considerably less variable than has been reported with other devices. Changes in central subfield thickness >8 μm can be considered more indicative of true clinical change rather than measurement variability. This finding informs clinical practice and clinical trial design.

Entities:  

Mesh:

Year:  2012        PMID: 23111610     DOI: 10.1167/iovs.12-10895

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  21 in total

1.  Spectral-domain optical coherence tomography of macula in myopia.

Authors:  Janejit Choovuthayakorn; Taksaorn Laowong; Nawat Watanachai; Direk Patikulsila; Voraporn Chaikitmongkol
Journal:  Int Ophthalmol       Date:  2015-08-20       Impact factor: 2.031

2.  Calculating the predicted retinal thickness from spectral domain and time domain optical coherence tomography - comparison of different methods.

Authors:  Colin S Tan; Kelvin Z Li; Tock Han Lim
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-05-27       Impact factor: 3.117

3.  Comparison of subthreshold micropulse laser (577 nm) treatment and half-dose photodynamic therapy in patients with chronic central serous chorioretinopathy.

Authors:  P Scholz; L Altay; S Fauser
Journal:  Eye (Lond)       Date:  2016-07-08       Impact factor: 3.775

4.  Macular structural characteristics in children with Down syndrome.

Authors:  Scott O'Brien; Jingyun Wang; Heather A Smith; Dana L Donaldson; Kathryn M Haider; Gavin J Roberts; Derek T Sprunger; Daniel E Neely; David A Plager
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-07-02       Impact factor: 3.117

5.  Reproducibility of spectral-domain optical coherence tomography retinal thickness measurements and conversion to equivalent time-domain metrics in diabetic macular edema.

Authors:  Susan B Bressler; Allison R Edwards; Kakarla V Chalam; Neil M Bressler; Adam R Glassman; Glenn J Jaffe; Michele Melia; David D Saggau; Oren Z Plous
Journal:  JAMA Ophthalmol       Date:  2014-09       Impact factor: 7.389

6.  Reproducibility of Optovue RTVue Optical Coherence Tomography Retinal Thickness Measurements and Conversion to Equivalent Zeiss Stratus Metrics in Diabetic Macular Edema.

Authors:  Susan B Bressler; Allison R Edwards; Christopher M Andreoli; Paul Andrew Edwards; Adam R Glassman; Glenn J Jaffe; Michele Melia; Jennifer K Sun
Journal:  Transl Vis Sci Technol       Date:  2015-01-22       Impact factor: 3.283

7.  Changes in Central Macular Thickness following Single Session Multispot Panretinal Photocoagulation.

Authors:  Nawat Watanachai; Janejit Choovuthayakorn; Direk Patikulsila; Nimitr Ittipunkul
Journal:  J Ophthalmol       Date:  2015-01-28       Impact factor: 1.909

8.  Interobserver agreement in detecting spectral-domain optical coherence tomography features of diabetic macular edema.

Authors:  Ling Zhi Heng; Maria Pefkianaki; Maria Pefianaki; Philip Hykin; Praveen J Patel
Journal:  PLoS One       Date:  2015-05-21       Impact factor: 3.240

9.  Use of optical coherence tomography and electroretinography to evaluate retinal pathology in a mouse model of autoimmune uveitis.

Authors:  Jun Chen; Haohua Qian; Reiko Horai; Chi-Chao Chan; Rachel R Caspi
Journal:  PLoS One       Date:  2013-05-14       Impact factor: 3.240

10.  Role of Cold Balanced Salt Solution (BSS) in the Prophylaxis of Cystoid Macular Edema After Cataract Surgery: A Prospective Randomized Study.

Authors:  Alessandro Meduri; Giovanni William Oliverio; Loredana Bergandi; Gabriella De Salvo; Rino Frisina; Cosimo Mazzotta; Pasquale Aragona
Journal:  Clin Ophthalmol       Date:  2021-06-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.