Literature DB >> 23107301

AARC clinical practice guideline: transcutaneous monitoring of carbon dioxide and oxygen: 2012.

Ruben D Restrepo1, Keith R Hirst, Leonard Wittnebel, Richard Wettstein.   

Abstract

An electronic literature search for articles published between January 1990 and September 2011 was conducted by using the PubMed, CINAHL, SCOPUS, and Cochrane Library databases. The update of this clinical practice guideline is the result of reviewing a total of 124 articles: 3 randomized controlled trials, 103 prospective trials, 1 retrospective study, 3 case studies, 11 review articles, 2 surveys and 1 consensus paper on transcutaneous monitoring (TCM) for P(tcO(2)) and P(tcCO(2)). The following recommendations are made following the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) criteria: (1) Although P(tcCO(2)) has a good correlation with P(aCO(2)) and is a reliable method to evaluate plasma CO(2) levels, it is recommended that arterial blood gas values be compared to transcutaneous readings taken at the time of arterial sampling, in order to verify the transcutaneous values, and periodically as dictated by the patient's clinical condition. (2) It is suggested that P(tcCO(2)) may be used in clinical settings where monitoring the adequacy of ventilation is indicated. (3) It is suggested that P(tcO(2)) and P(tcCO(2)) may be used in determining the adequacy of tissue perfusion and monitoring of reperfusion. (4) It is suggested that TCM should be avoided in the presence of increased thickness or edema of the skin and/or subcutaneous tissue where the sensor is applied. (5) It is recommended that sites used for a TCM be changed as often as necessary and that they be alternated and observed to avoid thermal injury. Manufacturer recommendations should be followed.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23107301     DOI: 10.4187/respcare.02011

Source DB:  PubMed          Journal:  Respir Care        ISSN: 0020-1324            Impact factor:   2.258


  16 in total

1.  A rate-based transcutaneous CO2 sensor for noninvasive respiration monitoring.

Authors:  M Chatterjee; X Ge; Y Kostov; P Luu; L Tolosa; H Woo; R Viscardi; S Falk; R Potts; G Rao
Journal:  Physiol Meas       Date:  2015-04-02       Impact factor: 2.833

2.  Are transcutaneous oxygen and carbon dioxide determinations of value in pulmonary arterial hypertension?

Authors:  Adriano R Tonelli; Laith Alkukhun; Frank Cikach; Mostafa Ahmed; Raed A Dweik
Journal:  Microcirculation       Date:  2015-05       Impact factor: 2.628

Review 3.  Novel methods in pulmonary hypertension phenotyping in the age of precision medicine (2015 Grover Conference series).

Authors:  Jarrod W Barnes; Adriano R Tonelli; Gustavo A Heresi; Jennie E Newman; Noël E Mellor; David E Grove; Raed A Dweik
Journal:  Pulm Circ       Date:  2016-12       Impact factor: 3.017

4.  Continuous positive airway pressure (CPAP) vs noninvasive positive pressure ventilation (NIPPV) vs noninvasive high frequency oscillation ventilation (NHFOV) as post-extubation support in preterm neonates: protocol for an assessor-blinded, multicenter, randomized controlled trial.

Authors:  Yuan Shi; Daniele De Luca
Journal:  BMC Pediatr       Date:  2019-07-26       Impact factor: 2.125

Review 5.  Transcutaneous PCO2 monitoring in critically ill patients: update and perspectives.

Authors:  Arnaud Mari; Hélène Nougue; Joaquim Mateo; Benoît Vallet; Fabrice Vallée
Journal:  J Thorac Dis       Date:  2019-07       Impact factor: 2.895

6.  Agreement of Mixed Venous Carbon Dioxide Tension (PvCO2) and Transcutaneous Carbon Dioxide (PtCO2) Measurements in Ventilated Infants.

Authors:  Sinan Uslu; Ali Bulbul; Mesut Dursun; Umut Zubarioglu; Ebru Turkoglu; Omer Guran
Journal:  Iran J Pediatr       Date:  2015-01-19       Impact factor: 0.364

7.  Concordance and limits between transcutaneous and arterial carbon dioxide pressure in emergency department patients with acute respiratory failure: a single-center prospective observational study.

Authors:  Xavier Bobbia; Pierre-Géraud Claret; Ludovic Palmier; Michaël Robert; Romain Genre Grandpierre; Claire Roger; Patrick Ray; Mustapha Sebbane; Laurent Muller; Jean-Emmanuel de La Coussaye
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2015-05-17       Impact factor: 2.953

8.  Comparison of arterial CO2 estimation by end-tidal and transcutaneous CO2 measurements in intubated children and variability with subject related factors.

Authors:  Muhterem Duyu; Yasemin Mocan Çağlar; Zeynep Karakaya; Mine Usta Aslan; Seyhan Yılmaz; Aslı Nur Ören Leblebici; Anıl Doğan Bektaş; Meral Bahar; Meryem Nihal Yersel
Journal:  J Clin Monit Comput       Date:  2020-07-27       Impact factor: 2.502

9.  Performance of capnometry in non-intubated infants in the pediatric intensive care unit.

Authors:  Bria M Coates; Robin Chaize; Denise M Goodman; Ranna A Rozenfeld
Journal:  BMC Pediatr       Date:  2014-06-25       Impact factor: 2.125

10.  Erratum: Concordance and limits between transcutaneous and arterial carbon dioxide pressure in emergency department patients with acute respiratory failure: a single-center, prospective, and observational study.

Authors:  Xavier Bobbia; Pierre-Géraud Claret; Ludovic Palmier; Michaël Robert; Romain Genre Granpierre; Claire Roger; Justin Yan; Patrick Ray; Mustapha Sebbane; Laurent Muller; Jean-Emmanuel de La Coussaye
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2015-10-06       Impact factor: 2.953

View more