Abstract

Electron transfer (ET) in redox-labeled double-stranded (ds) DNA tethered to electrodes through the alkanethiol linker at either the 3' or 5' DNA end and bearing methylene blue (MB) conjugated to the opposite end of DNA is shown to depend on the DNA end of tethering to electrodes. For 3' tethering, a nanoscale diffusion of the positively charged MB redox probe (and thus of the individual DNA molecules) to the negatively charged electrode surface provided the highest apparent diffusion and ET rates as a result of the tilting of 3'-tethered DNA (as compared to 5'-tethered DNA) versus the normal to the surface. Dynamic values of the tilting angle varied between 57 and 45° for 16-mer and 22-mer 3'-tethered DNA, and 5'-tethering was correlated with an upright orientation of DNA at the electrode surface. The values of the diffusion coefficient D(MB) corrected for tilting angles were similar for 5'- and 3'-tethered DNA and ranged between 5.4 × 10(-12) and 2.5 × 10(-12) cm(2) s(-1), whereas the ET rate constant k(ET)(dif) fit the 4.7 × 10(-6)-10.3 × 10(-6) cm s(-1) range for 22-mer and 16-mer dsDNA, respectively. Those values, when related to the nanometer (10(-7) cm) diffusion distances (the length of the studied DNA), allow relatively fast diffusion-limited ET at an apparent rate that may exceed the rate of the corresponding surface-confined ET process. This phenomenon is of particular importance for molecular electronics and electrochemical genosensor development.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23106377     DOI: 10.1021/la3032336

Source DB:  PubMed          Journal:  Langmuir        ISSN: 0743-7463            Impact factor:   3.882


  5 in total

1.  A reagentless DNA-based electrochemical silver(I) sensor for real time detection of Ag(I) - the effect of probe sequence and orientation on sensor response.

Authors:  Yao Wu; Rebecca Y Lai
Journal:  Biotechnol J       Date:  2016-03-15       Impact factor: 4.677

2.  Intraduplex DNA-mediated electrochemistry of covalently tethered redox-active reporters.

Authors:  Catrina G Pheeney; Jacqueline K Barton
Journal:  J Am Chem Soc       Date:  2013-09-30       Impact factor: 15.419

3.  Electrochemical Studies of Cation Condensation-Induced Collapse of Surface-Bound DNA.

Authors:  Kiana S Sykes; Luiz F L Oliveira; George Stan; Ryan J White
Journal:  Langmuir       Date:  2019-09-25       Impact factor: 3.882

4.  Reagentless, Structure-Switching, Electrochemical Aptamer-Based Sensors.

Authors:  Lauren R Schoukroun-Barnes; Florika C Macazo; Brenda Gutierrez; Justine Lottermoser; Juan Liu; Ryan J White
Journal:  Annu Rev Anal Chem (Palo Alto Calif)       Date:  2016-04-06       Impact factor: 10.745

5.  Specifically horizontally tethered DNA probes on Au surfaces allow labelled and label-free DNA detection using SERS and electrochemically driven melting.

Authors:  E Papadopoulou; N Gale; J F Thompson; T A Fleming; T Brown; P N Bartlett
Journal:  Chem Sci       Date:  2015-10-08       Impact factor: 9.825

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.