Mechanisms Underlying Isovolumic Contraction and Ejection Peaks in Seismocardiogram Morphology.

Viatcheslav Gurev1, Kouhyar Tavakolian, Jason Constantino, Bozena Kaminska, Andrew P Blaber, Natalia A Trayanova.   

Abstract

A three-dimensional (3D) finite element electromechanical model of the heart is employed in simulations of seismocardiograms (SCGs). To simulate SCGs, a previously developed 3D model of ventricular contraction is extended by adding the mechanical interaction of the heart with the chest and internal organs. The proposed model reproduces the major peaks of seismocardiographic signals during the phases of the cardiac cycle. Results indicate that SCGs record the pressure of the heart acting on the ribs. In addition, the model reveals that the rotation of the rib with respect to the heart has a minor effect on seismocardiographic signal morphology during the respiratory cycle. SCGs are obtained from 24 human volunteers and their morphology is analyzed. Experimental results demonstrate that the peak of the maximum acceleration of blood in the aorta occurs at the same time as the global minimum of the SCG. It is confirmed that the first SCG peak after the electrocardiogram R-wave corresponds to aortic valve opening, as determined from the impedance cardiogram (p = 0.92). The simulation results reveal that the SCG peaks corresponding to aortic valve opening and the maximum acceleration of blood in the aorta result from ventricular contraction in the longitudinal direction of the ventricles and a decrease in the dimensions of the ventricles due to the ejection of blood, respectively.

Entities:  

Year:  2012        PMID: 23105942      PMCID: PMC3480230          DOI: 10.5405/jmbe.847

Source DB:  PubMed          Journal:  J Med Biol Eng        ISSN: 1609-0985            Impact factor:   1.553


  9 in total

1.  Systolic and diastolic cardiac function time intervals and exercise capacity in women.

Authors:  J R Libonati; A M Colby; T M Caldwell; R Kasparian; H L Glassberg
Journal:  Med Sci Sports Exerc       Date:  1999-02       Impact factor: 5.411

2.  Improvement of ballistocardiogram processing by inclusion of respiration information.

Authors:  Kouhyar Tavakolian; Ali Vaseghi; Bozena Kaminska
Journal:  Physiol Meas       Date:  2008-06-18       Impact factor: 2.833

3.  ECG beat detection using filter banks.

Authors:  V X Afonso; W J Tompkins; T Q Nguyen; S Luo
Journal:  IEEE Trans Biomed Eng       Date:  1999-02       Impact factor: 4.538

4.  Reevaluation of hemodynamic consequences of positive pressure ventilation: emphasis on cyclic right ventricular afterloading by mechanical lung inflation.

Authors:  F Jardin; G Delorme; A Hardy; B Auvert; A Beauchet; J P Bourdarias
Journal:  Anesthesiology       Date:  1990-06       Impact factor: 7.892

5.  Precordial palpation.

Authors:  J F Stapleton; B M Groves
Journal:  Am Heart J       Date:  1971-03       Impact factor: 4.749

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

7.  Models of cardiac electromechanics based on individual hearts imaging data: image-based electromechanical models of the heart.

Authors:  Viatcheslav Gurev; Ted Lee; Jason Constantino; Hermenegild Arevalo; Natalia A Trayanova
Journal:  Biomech Model Mechanobiol       Date:  2010-06-30

8.  Comparative analysis of three different modalities for characterization of the seismocardiogram.

Authors:  Alireza Akhbardeh; Kouhyar Tavakolian; Viatcheslav Gurev; Ted Lee; William New; Bozena Kaminska; Natalia Trayanova
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

9.  Quantitative assessment of intrinsic regional myocardial deformation by Doppler strain rate echocardiography in humans: validation against three-dimensional tagged magnetic resonance imaging.

Authors:  Thor Edvardsen; Bernhard L Gerber; Jérôme Garot; David A Bluemke; João A C Lima; Otto A Smiseth
Journal:  Circulation       Date:  2002-07-02       Impact factor: 29.690

  9 in total
  11 in total

1.  A Unified Framework for Quality Indexing and Classification of Seismocardiogram Signals.

Authors:  Jonathan Zia; Jacob Kimball; Sinan Hersek; Md Mobashir Hasan Shandhi; Beren Semiz; Omer T Inan
Journal:  IEEE J Biomed Health Inform       Date:  2019-07-26       Impact factor: 5.772

2.  4D cardiac electromechanical activation imaging.

Authors:  Julien Grondin; Dafang Wang; Christopher S Grubb; Natalia Trayanova; Elisa E Konofagou
Journal:  Comput Biol Med       Date:  2019-08-06       Impact factor: 4.589

3.  Modeling Consistent Dynamics of Cardiogenic Vibrations in Low-Dimensional Subspace.

Authors:  Jonathan Zia; Jacob Kimball; Sinan Hersek; Omer T Inan
Journal:  IEEE J Biomed Health Inform       Date:  2020-03-16       Impact factor: 5.772

4.  Automatic Identification of Systolic Time Intervals in Seismocardiogram.

Authors:  Ghufran Shafiq; Sivanagaraja Tatinati; Wei Tech Ang; Kalyana C Veluvolu
Journal:  Sci Rep       Date:  2016-11-22       Impact factor: 4.379

5.  Time-Frequency Distribution of Seismocardiographic Signals: A Comparative Study.

Authors:  Amirtaha Taebi; Hansen A Mansy
Journal:  Bioengineering (Basel)       Date:  2017-04-07

6.  Forcecardiography: A Novel Technique to Measure Heart Mechanical Vibrations onto the Chest Wall.

Authors:  Emilio Andreozzi; Antonio Fratini; Daniele Esposito; Ganesh Naik; Caitlin Polley; Gaetano D Gargiulo; Paolo Bifulco
Journal:  Sensors (Basel)       Date:  2020-07-13       Impact factor: 3.576

7.  Assessment of left ventricular twist by 3D ballistocardiography and seismocardiography compared with 2D STI echocardiography in a context of enhanced inotropism in healthy subjects.

Authors:  Sofia Morra; Amin Hossein; Jérémy Rabineau; Damien Gorlier; Judith Racape; Pierre-François Migeotte; Philippe van de Borne
Journal:  Sci Rep       Date:  2021-01-12       Impact factor: 4.379

Review 8.  Gyrocardiography: A Review of the Definition, History, Waveform Description, and Applications.

Authors:  Szymon Sieciński; Paweł S Kostka; Ewaryst J Tkacz
Journal:  Sensors (Basel)       Date:  2020-11-22       Impact factor: 3.576

9.  Mechanocardiography in the Detection of Acute ST Elevation Myocardial Infarction: The MECHANO-STEMI Study.

Authors:  Tero Koivisto; Olli Lahdenoja; Tero Hurnanen; Tuija Vasankari; Samuli Jaakkola; Tuomas Kiviniemi; K E Juhani Airaksinen
Journal:  Sensors (Basel)       Date:  2022-06-09       Impact factor: 3.847

10.  Detection of Aortic Valve Opening and Estimation of Pre-Ejection Period in Forcecardiography Recordings.

Authors:  Jessica Centracchio; Emilio Andreozzi; Daniele Esposito; Gaetano Dario Gargiulo; Paolo Bifulco
Journal:  Bioengineering (Basel)       Date:  2022-02-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.