Literature DB >> 23104044

High-flexion prosthesis improves function of TKA in Asian patients without decreasing early survivorship.

Bum-Sik Lee1, Jong-Won Chung, Jong-Min Kim, Kyung-Ah Kim, Seong-Il Bin.   

Abstract

BACKGROUND: Two previous studies recently raised the possibility of a high risk of early femoral components loosening with high-flexion (HF) prostheses in Asian populations and suggested that the high failure rate of HF TKAs was associated with HF ability. However, these findings are controversial given other studies reporting a low incidence of aseptic failures in HF prostheses. QUESTIONS/PURPOSES: We therefore determined (1) the rate of achieving postoperative HF after HF TKA; (2) whether the aseptic loosening rate of HF prostheses is high; and (3) whether the survivorship was worsened in patients who achieved postoperative deep knee flexion in our cohort of Korean patients.
METHODS: We retrospectively reviewed 488 patients who had 698 primary TKAs using the NexGen(®) Legacy Posterior-Stabilized Flex system implanted from 2003 to 2010. There were 40 men and 448 women with a mean age of 68 years. We obtained Hospital for Special Surgery scores, maximal flexion, and radiographs. The minimum followup for functional and radiographic evaluations was 2 years (median, 4.8 years; range, 2-8.7 years). We performed a survival analysis on all patients for aseptic loosening.
RESULTS: Three hundred sixty knees (52%) could achieve ≥ 135° maximum flexion. Six of the 698 knees (0.9%) developed aseptic loosening (three femoral and three tibial). The survival at 5 years for aseptic loosening was 99.1%. The overall survival for aseptic failure did not differ between knees that achieved HF and those that did not.
CONCLUSIONS: We observed a low incidence of early aseptic loosening of HF designs in this series. Our findings suggest HF TKAs have high survival in Asian patients at 5 years although half of the patients attained maximum flexion more than 135° postoperatively.

Entities:  

Mesh:

Year:  2013        PMID: 23104044      PMCID: PMC3613537          DOI: 10.1007/s11999-012-2661-4

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  50 in total

1.  Knee joint kinematics in gait and other functional activities measured using flexible electrogoniometry: how much knee motion is sufficient for normal daily life?

Authors:  P J Rowe; C M Myles; C Walker; R Nutton
Journal:  Gait Posture       Date:  2000-10       Impact factor: 2.840

2.  Posterior-stabilized versus cruciate-retaining total knee arthroplasty: balancing the gap.

Authors:  Michael Tanzer; Karen Smith; Stephen Burnett
Journal:  J Arthroplasty       Date:  2002-10       Impact factor: 4.757

Review 3.  Does the new generation of high-flex knee prostheses improve the post-operative range of movement?: a meta-analysis.

Authors:  R Mehin; R S Burnett; P M A Brasher
Journal:  J Bone Joint Surg Br       Date:  2010-10

4.  Comparison of a standard and a gender-specific posterior cruciate-substituting high-flexion knee prosthesis: a prospective, randomized, short-term outcome study.

Authors:  Young-Hoo Kim; Yoowang Choi; Jun-Shik Kim
Journal:  J Bone Joint Surg Am       Date:  2010-08-18       Impact factor: 5.284

5.  Comparison of range of motion after standard and high-flexion posterior stabilised total knee replacement.

Authors:  F Y Ng; H L Wong; W P Yau; K Y Chiu; W M Tang
Journal:  Int Orthop       Date:  2007-09-22       Impact factor: 3.075

6.  Femoral component loosening in total knee arthroplasty.

Authors:  T V King; R D Scott
Journal:  Clin Orthop Relat Res       Date:  1985-04       Impact factor: 4.176

7.  Survivorship of total hip replacements.

Authors:  H S Dobbs
Journal:  J Bone Joint Surg Br       Date:  1980-05

8.  High-flex posterior cruciate-retaining vs posterior cruciate-substituting designs in simultaneous bilateral total knee arthroplasty: a prospective, randomized study.

Authors:  Kazuyoshi Yagishita; Takeshi Muneta; Young-Jin Ju; Toshiyuki Morito; Junya Yamazaki; Ichiro Sekiya
Journal:  J Arthroplasty       Date:  2011-06-15       Impact factor: 4.757

9.  Early clinical results of a high-flexion, posterior-stabilized, mobile-bearing total knee arthroplasty: a US investigational device exemption trial.

Authors:  Giles R Scuderi; David R Hedden; John A Maltry; Steven M Traina; Mitchell B Sheinkop; Mark A Hartzband
Journal:  J Arthroplasty       Date:  2011-08-19       Impact factor: 4.757

10.  Comparison between standard and high-flexion posterior-stabilized rotating-platform mobile-bearing total knee arthroplasties: a randomized controlled study.

Authors:  Won Chul Choi; Sahnghoon Lee; Sang Cheol Seong; Jong Hun Jung; Myung Chul Lee
Journal:  J Bone Joint Surg Am       Date:  2010-10-15       Impact factor: 5.284

View more
  10 in total

1.  Active Flexion in Weight Bearing Better Correlates with Functional Outcomes of Total Knee Arthroplasty than Passive Flexion.

Authors:  Young Dong Song; Nimash Jain; Yeon Gwi Kang; Tae Yune Kim; Tae Kyun Kim
Journal:  Knee Surg Relat Res       Date:  2016-06-01

Review 2.  High-flexion posterior-stabilized total knee prosthesis: is it worth the hype?

Authors:  Sanjeev Jain; Aditya Chandrashekhar Pathak; Kalaivanan Kanniyan; Sourabh Kulkarni; Sandeep Tawar; Prashant Mane
Journal:  Knee Surg Relat Res       Date:  2013-08-29

Review 3.  Patients achieved greater range of movement when using high-flexion implants.

Authors:  Canfeng Li; Yi Zeng; Bin Shen; Jing Yang; Zongke Zhou; Pengde Kang; Fuxing Pei
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-10-10       Impact factor: 4.342

4.  Differences in anatomy and kinematics in Asian and Caucasian TKA patients: influence on implant positioning and subsequent loading conditions in mobile bearing knees.

Authors:  Allan Maas; Tae Kyun Kim; Rolf K Miehlke; Thomas Hagen; Thomas M Grupp
Journal:  Biomed Res Int       Date:  2014-11-20       Impact factor: 3.411

5.  Midterm survivorship and clinical outcome of INDUS knee prosthesis: 5 year followup study.

Authors:  Kantilal H Sancheti; Parag K Sancheti; Rajeev S Joshi; Kailash R Patil; Ashok K Shyam; Raja R Bhaskar
Journal:  Indian J Orthop       Date:  2016 Mar-Apr       Impact factor: 1.251

6.  Minimum 5-year follow-up results and functional outcome of rotating-platform high-flexion total knee arthroplasty: A prospective study of 701 knees.

Authors:  Sanjeev Jain; Aditya C Pathak; K Kalaivanan
Journal:  Arthroplast Today       Date:  2016-06-06

7.  Clinical, Functional, and Midterm Survival Analysis on Sigma Curved Plus Ultracongruent Polyethylene Insert in Primary Total Knee Arthroplasty: A Retrospective Study.

Authors:  Neelam Reddy; Mukesh K Saini; Gattu Naresh; Ajay Thakur; Rajesh Podili; Jayavardhan Reddy
Journal:  Cureus       Date:  2020-11-17

Review 8.  Are Korean Patients Different from Other Ethnic Groups in Total Knee Arthroplasty?

Authors:  Dong-Kyoon Kim; Min-Chul Seo; Sang-Joon Song; Kang-Il Kim
Journal:  Knee Surg Relat Res       Date:  2015-12-01

9.  Total knee arthroplasty using NexGen LPS-flex® improves clinical outcomes without early loosening: minimum 6-year follow-up results.

Authors:  Yoon Sang Jeon; Joong Sup Shin; Jae Ho Jung; Myung Ku Kim
Journal:  J Orthop Surg Res       Date:  2016-07-21       Impact factor: 2.359

10.  Two- to Four-Year Follow-up Results of Total Knee Arthroplasty Using a New High-Flexion Prosthesis.

Authors:  Man Soo Kim; In Jun Koh; Sung Won Jang; Neung Han Jeon; Yong In
Journal:  Knee Surg Relat Res       Date:  2016-02-29
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.