Literature DB >> 10998612

Knee joint kinematics in gait and other functional activities measured using flexible electrogoniometry: how much knee motion is sufficient for normal daily life?

P J Rowe1, C M Myles, C Walker, R Nutton.   

Abstract

The knee joint kinematics of a group (n=20) of elderly normal subjects (mean age=67 years) were investigated using flexible electrogoniometry. The flexion-extension angle of the knee was recorded during a range of functional activities performed as part of a circuit in and around the hospital. The functions analysed including gait, walking on slopes, stair negotiation, the use of standard and low chairs and a bath. The data were used to produce the pattern of joint angulation against the percentage of the cycle for each individual conducting each activity. Further the maximum and minimum knee joint angles and the excursion of the joint during the cycle were identified. The results indicate gait and slopes require less than 90 degrees of knee flexion, stairs and chairs 90-120 degrees of flexion and a bath approximately 135 degrees of flexion. The data suggests that 110 degrees of flexion would seem a suitable goal for the rehabilitation of motion in the knee. It is concluded that flexible electrogoniometry is a suitable and practical method for evaluating knee motion during a range of functional activities.

Mesh:

Year:  2000        PMID: 10998612     DOI: 10.1016/s0966-6362(00)00060-6

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  68 in total

Review 1.  How to read a postoperative knee replacement radiograph.

Authors:  Nawfal Al-Hadithy; Madhavan C Papanna; Sana Farooq; Yegappan Kalairajah
Journal:  Skeletal Radiol       Date:  2011-10-16       Impact factor: 2.199

Review 2.  Regional analgesia for improvement of long-term functional outcome after elective large joint replacement.

Authors:  Arthur Atchabahian; Gary Schwartz; Charles B Hall; Claudette M Lajam; Michael H Andreae
Journal:  Cochrane Database Syst Rev       Date:  2015-08-13

3.  A comparison of patient-reported and measured range of motion in a cohort of total knee arthroplasty patients.

Authors:  Jamie E Collins; Benjamin N Rome; Meghan E Daigle; Vladislav Lerner; Jeffrey N Katz; Elena Losina
Journal:  J Arthroplasty       Date:  2014-02-26       Impact factor: 4.757

4.  Recovery of knee range of motion after total knee arthroplasty in the first postoperative weeks: poor recovery can be detected early.

Authors:  A Kornuijt; G J L de Kort; D Das; A F Lenssen; W van der Weegen
Journal:  Musculoskelet Surg       Date:  2019-01-09

5.  Effects of Aquatic Therapy and Land-Based Therapy versus Land-Based Therapy Alone on Range of Motion, Edema, and Function after Hip or Knee Replacement: A Systematic Review and Meta-analysis.

Authors:  Alison J Gibson; Nora Shields
Journal:  Physiother Can       Date:  2015       Impact factor: 1.037

6.  Optimisation of the posterior stabilised tibial post for greater femoral rollback after total knee arthroplasty--a finite element analysis.

Authors:  Nagarajan Chandran; Farid Amirouche; Mark H Gonzalez; Kevin M Hilton; Riad Barmada; Wayne Goldstein
Journal:  Int Orthop       Date:  2008-07-02       Impact factor: 3.075

7.  Indoor and Outdoor Mobility following Total Knee Arthroplasty.

Authors:  Ava S T Storey; Ainslie M Myrah; Robyn A Bauck; Danielle M Brinkman; Shawn N Friess; Sandra C Webber
Journal:  Physiother Can       Date:  2013       Impact factor: 1.037

8.  Do high flexion posterior stabilised total knee arthroplasty designs increase knee flexion? A meta analysis.

Authors:  Takanobu Sumino; Hemanth R Gadikota; Kartik M Varadarajan; Young-Min Kwon; Harry E Rubash; Guoan Li
Journal:  Int Orthop       Date:  2011-03-16       Impact factor: 3.075

9.  Continuous passive motion and its effects on knee flexion after total knee arthroplasty in patients with knee osteoarthritis.

Authors:  Chun-De Liao; Yi-Ching Huang; Li-Fong Lin; Yen-Shuo Chiu; Jui-Chen Tsai; Chun-Lung Chen; Tsan-Hon Liou
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-08-19       Impact factor: 4.342

10.  The INDUS knee prosthesis - Prospective multicentric trial of a posteriorly stabilized high-flex design: 2 years follow-up.

Authors:  Kantilal H Sancheti; Nandu S Laud; Harish Bhende; Gurava Reddy; Neema Pramod; Joseph N Mani
Journal:  Indian J Orthop       Date:  2009-10       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.