Literature DB >> 23103778

Relation between mixed venous oxygen saturation and cerebral oxygen saturation measured by absolute and relative near-infrared spectroscopy during off-pump coronary artery bypass grafting.

A Moerman1, G Vandenplas, T Bové, P F Wouters, S G De Hert.   

Abstract

BACKGROUND: We hypothesized that previously reported contradictory results regarding the equivalence of mixed venous (Smv(O(2))) and cerebral (rS(c)O(2)) oxygen saturation might be related to time delay issues and to measurement technology. In order to explore these two factors, we designed a prospective clinical study comparing with relative (INVOS(®)) and absolute (Foresight(®)) rS(c)O(2) measurements.
METHODS: Forty-two consenting patients undergoing elective off-pump coronary artery bypass grafting were included. Two INVOS and two Foresight sensors continuously registered rS(c)O(2). Smv(O(2)) was measured continuously via a pulmonary artery catheter. Data were assessed by within- and between-group comparisons and correlation analysis.
RESULTS: A similar time delay of 19 (4) and 18 (4) s was found for compared with rS(c)O(2) measurements by Foresight and INVOS, respectively, during haemodynamic changes. After adjusting for this time delay, the correlation between Smv(O(2)) and rS(c)O(2) increased from r=0.25 to 0.75 (P<0.001) for Foresight, and from r=0.28 to 0.73 (P<0.001) for INVOS. Comparison of Foresight and INVOS revealed significant differences in absolute rS(c)O(2) values (range 58-89% for Foresight and 28-95% for INVOS). Changes in rS(c)O(2) in response to acute haemodynamic alterations were significantly more pronounced with INVOS compared with Foresight (P<0.001).
CONCLUSIONS: Considering the important time delay with Smv(O(2)), rS(c)O(2) seems to reflect more appropriately acute haemodynamic alterations. This might suggest its use as a valid alternative to invasive monitoring of tissue oxygen saturation. Relative and absolute rS(c)O(2) measurements demonstrated significant differences in measured rS(c)O(2) values and in the magnitude of rS(c)O(2) changes during haemodynamic alterations.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23103778     DOI: 10.1093/bja/aes375

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  14 in total

Review 1.  In vivo validation of cerebral near-infrared spectroscopy: a review.

Authors:  Amalie la Cour; Gorm Greisen; Simon Hyttel-Sorensen
Journal:  Neurophotonics       Date:  2018-11-27       Impact factor: 3.593

2.  Evaluation of different near-infrared spectroscopy technologies for assessment of tissue oxygen saturation during a vascular occlusion test.

Authors:  Kevin Steenhaut; Koen Lapage; Thierry Bové; Stefan De Hert; Annelies Moerman
Journal:  J Clin Monit Comput       Date:  2016-11-22       Impact factor: 2.502

Review 3.  [Near-infrared spectroscopy : Technique, development, current use and perspectives].

Authors:  D Bolkenius; C Dumps; B Rupprecht
Journal:  Anaesthesist       Date:  2021-03       Impact factor: 1.041

Review 4.  Cerebral Oximetry and Autoregulation during Cardiopulmonary Bypass: A Review.

Authors:  Nousjka P A Vranken; Patrick W Weerwind; Nadia A Sutedja; Ervin E Ševerdija; Paul J C Barenbrug; Jos G Maessen
Journal:  J Extra Corpor Technol       Date:  2017-09

5.  Cerebral oxygen desaturation occurs frequently in patients with hypertension undergoing major abdominal surgery.

Authors:  Hongyi Li; Qiaochu Fu; Zongfang Wu; Jiaoli Sun; Anne Manyande; Hui Yang; Peng Wang
Journal:  J Clin Monit Comput       Date:  2017-05-09       Impact factor: 2.502

6.  Effects of propofol versus sevoflurane on cerebral circulation time in patients undergoing coiling for cerebral artery aneurysm: a prospective randomized crossover study.

Authors:  Tomoko Ishibashi; Satoshi Toyama; Kazunori Miki; Jun Karakama; Yoshikazu Yoshino; Satoru Ishibashi; Makoto Tomita; Shigeru Nemoto
Journal:  J Clin Monit Comput       Date:  2019-01-04       Impact factor: 2.502

7.  10 cm H2O PEEP application in laparoscopic surgery and cerebral oxygenation: a comparative study with INVOS and FORESIGHT.

Authors:  Perihan Uçar Kemerci; Aslı Demir; Bahar Aydınlı; Çiğdem Yıldırım Güçlü; Ümit Karadeniz; Ömer Faruk Çiçek; İrfan Taşoğlu; Ayşegül Özgök
Journal:  Surg Endosc       Date:  2015-06-23       Impact factor: 4.584

8.  Factors associated with a low initial cerebral oxygen saturation value in patients undergoing cardiac surgery.

Authors:  Kensuke Kobayashi; Tadashi Kitamura; Satoshi Kohira; Shinzo Torii; Tetsuya Horai; Mitsuhiro Hirata; Toshiaki Mishima; Koichi Sughimoto; Hirotoki Ohkubo; Yusuke Irisawa; Takuya Matsushiro; Hidenori Hayashi; Yurie Miyata; Yuta Tsuchida; Naoki Ohtomo; Kagami Miyaji
Journal:  J Artif Organs       Date:  2017-01-04       Impact factor: 1.731

Review 9.  Cerebral near-infrared spectroscopy in the care of patients during cardiological procedures: a summary of the clinical evidence.

Authors:  Annelies Moerman; Frederik Meert; Stefan De Hert
Journal:  J Clin Monit Comput       Date:  2015-10-08       Impact factor: 2.502

10.  Direct comparison between cerebral oximetry by INVOS(TM) and EQUANOX(TM) during cardiac surgery: a pilot study.

Authors:  A Pisano; N Galdieri; T P Iovino; M Angelone; A Corcione
Journal:  Heart Lung Vessel       Date:  2014
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.