Literature DB >> 23103033

Prospective, Randomized, Multicenter Evaluation of a Polyethylene Terephthalate Micronet Mesh-Covered Stent (MGuard) in ST-Segment Elevation Myocardial Infarction: The MASTER Trial.

Gregg W Stone1, Alexandre Abizaid, Sigmund Silber, Jose M Dizon, Béla Merkely, Ricardo A Costa, Ran Kornowski, Andrea Abizaid, Roman Wojdyła, Akiko Maehara, Ovidiu Dressler, Sorin J Brener, Eli Bar, Dariusz Dudek.   

Abstract

OBJECTIVES: This study sought to evaluate the potential utility of a novel polyethylene terephthalate micronet mesh-covered stent (MGuard) in patients with acute ST-segment elevation myocardial infarction (STEMI) undergoing percutaneous coronary intervention (PCI).
BACKGROUND: Suboptimal myocardial reperfusion after PCI in STEMI is common and results in increased infarct size and mortality. The MGuard is a novel thin-strut metal stent with a polyethylene terephthalate micronet covering designed to trap and exclude thrombus and friable atheromatous debris to prevent distal embolization.
METHODS: A total of 433 patients with STEMI presenting within 12 h of symptom onset undergoing PCI were randomized at 50 sites in 9 countries to the MGuard (n = 217) or commercially available bare metal or drug-eluting stents (n = 216). The primary endpoint was the rate of complete (≥70%) ST-segment resolution measured 60 to 90 min post-procedure.
RESULTS: Baseline characteristics were well matched between the groups. The primary endpoint of post-procedure complete ST-segment resolution was significantly improved in patients randomized to the MGuard stent compared with control patients (57.8% vs. 44.7%; difference: 13.2%; 95% confidence interval: 3.1% to 23.3%; p = 0.008). By core laboratory analysis, the MGuard stent compared with control stents also resulted in superior rates of Thrombolysis In Myocardial Infarction 3 flow (91.7% vs. 82.9%, p = 0.006) with comparable rates of myocardial blush grade 2 or 3 (83.9% vs. 84.7%, p = 0.81). Mortality (0% vs. 1.9%, p = 0.06) and major adverse cardiac events (1.8% vs. 2.3%, p = 0.75) at 30 days were not significantly different between patients randomized to the MGuard stent and control stent, respectively.
CONCLUSIONS: Among patients with acute STEMI undergoing emergent PCI, the MGuard micronet mesh-covered stent compared with conventional metal stents resulted in superior rates of epicardial coronary flow and complete ST-segment resolution. A larger randomized trial is warranted to determine whether these benefits result in reduced infarct size and/or improved clinical outcomes. (Safety and Efficacy Study of MGuard Stent After a Heart Attack [MASTER]; NCT01368471).

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23103033     DOI: 10.1016/j.jacc.2012.09.004

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  21 in total

1.  Accidental Stenting Out of Stent: A Lesson from No-Reflow after New Stent Deployment Outside the Prior Stent.

Authors:  Chih-Hung Lai; Shih-Hsien Sung; Wen-Lieng Lee; Yu-Hsiang Juan; Szu-Ling Chang; Tse-Min Lu
Journal:  Acta Cardiol Sin       Date:  2016-05       Impact factor: 2.672

Review 2.  Drug-eluting stents and acute myocardial infarction: A lethal combination or friends?

Authors:  Shuji Otsuki; Manel Sabaté
Journal:  World J Cardiol       Date:  2014-09-26

Review 3.  [Thrombus aspiration in patients with acute myocardial infarction : Scientific evidence and guideline recommendations].

Authors:  T Stiermaier; S de Waha; G Fürnau; I Eitel; H Thiele; S Desch
Journal:  Herz       Date:  2016-03-15       Impact factor: 1.443

Review 4.  Drug-eluting stents versus bare-metal stents for acute coronary syndrome.

Authors:  Joshua Feinberg; Emil Eik Nielsen; Janette Greenhalgh; Juliet Hounsome; Naqash J Sethi; Sanam Safi; Christian Gluud; Janus C Jakobsen
Journal:  Cochrane Database Syst Rev       Date:  2017-08-23

5.  Evidence for a novel racemization process of an asparaginyl residue in mouse lysozyme under physiological conditions.

Authors:  K Ueno; T Ueda; K Sakai; Y Abe; N Hamasaki; M Okamoto; T Imoto
Journal:  Cell Mol Life Sci       Date:  2005-01       Impact factor: 9.261

Review 6.  Thrombus aspiration in primary angioplasty for ST-segment elevation myocardial infarction.

Authors:  Roberta Serdoz; Michele Pighi; Nikolaos V Konstantinidis; Ismail Dogu Kilic; Sara Abou-Sherif; Carlo Di Mario
Journal:  Curr Atheroscler Rep       Date:  2014-08       Impact factor: 5.113

7.  Interventional Strategies in Thrombus Management for ST Elevation Myocardial Infarction.

Authors:  Michael Tsang; Sanjit Jolly
Journal:  Interv Cardiol       Date:  2015-03

8.  MGuard Embolic Protection Stent - The Importance of Thrombus Management in ST-elevation Myocardial Infarction Primary Percutaneous Coronary Intervention: Proceedings of STEMI symposium at EuroPCR on 20-23rd May 2014 in Paris.

Authors:  Katrina Mountfort; Ricardo Costa; Alexandre Abizaid; Jean Fajadet; Chaim Lotan; Ran Kornowski; Dariusz Dudek; Jose Ps Henriques; Giovanni Amoroso
Journal:  Interv Cardiol       Date:  2014-08

Review 9.  Coronary thrombus in patients undergoing primary PCI for STEMI: Prognostic significance and management.

Authors:  Sabine Vecchio; Elisabetta Varani; Tania Chechi; Marco Balducelli; Giuseppe Vecchi; Matteo Aquilina; Giulia Ricci Lucchi; Alessandro Dal Monte; Massimo Margheri
Journal:  World J Cardiol       Date:  2014-06-26

10.  Hydrogel-mesh composite for wound closure.

Authors:  Yang Gao; Xiuyuan Han; Jiaojiao Chen; Yudong Pan; Meng Yang; Linhe Lu; Jian Yang; Zhigang Suo; Tongqing Lu
Journal:  Proc Natl Acad Sci U S A       Date:  2021-07-13       Impact factor: 11.205

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.