Literature DB >> 23101534

Optimal Jamar dynamometer handle position to assess maximal isometric hand grip strength in epidemiological studies.

Ulrike Sonja Trampisch1, Julia Franke, Nina Jedamzik, Timo Hinrichs, Petra Platen.   

Abstract

PURPOSE: Hand grip strength is an indicator of general muscle strength that is measured using a hand dynamometer. In some studies, a subject's grip strength is taken to be the maximal grip strength achieved from measurements taken at several different dynamometer handle positions. However, little is known about the influence of these different positions on the measured grip strength. The aim of the study was to identify one standard handle position that could be used to assess the grip strength of all subjects.
METHODS: Grip strength was assessed with a hand dynamometer (Jamar Plus+; Sammons Preston, Rolyon, Bolingbrook, IL). Each participant's grip strength was measured 3 times in each of 5 different handle positions with each hand. The best position for each participant was defined as the position at which they achieved maximal grip strength.
RESULTS: The mean (± standard deviation) age of the 50 participants was 41 (± 13) years. Maximal grip strength was 43.7 (± 12.4) kg for all participants; 55.0 (± 10.2) kg for men and 35.4 (± 5.2) kg for women. Handle position 2 was the best position for 70% of participants. The mean difference between the grip strength achieved by each participant at handle position 2 and that achieved at each participant's best position was 0.8 (± 1.78) kg.
CONCLUSIONS: Our results show that measurements taken at a single standard handle position are sufficiently accurate to assess grip strengths for all subjects. We therefore recommend handle position 2 as the standard position for measuring grip strength with the Jamar Plus+ hand dynamometer. CLINICAL RELEVANCE: The assessment of grip strength with the Jamar Plus+ dynamometer is easier and faster if a single, standard handle position is used rather than multiple different positions. As well as providing accurate results, a single, standard handle position also reduces fatigue and increases the comparability of results between subjects.
Copyright © 2012 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23101534     DOI: 10.1016/j.jhsa.2012.08.014

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  43 in total

1.  Is Use of a Psychological Workbook Associated With Improved Disabilities of the Arm, Shoulder and Hand Scores in Patients With Distal Radius Fracture?

Authors:  Stuart Goudie; Diane Dixon; Gail McMillan; David Ring; Margaret McQueen
Journal:  Clin Orthop Relat Res       Date:  2018-04       Impact factor: 4.176

2.  Reduced handgrip strength as a marker of frailty predicts clinical outcomes in patients with heart failure undergoing ventricular assist device placement.

Authors:  Christine J Chung; Christina Wu; Meaghan Jones; Tomoko S Kato; Tien T Dam; Raymond C Givens; Danielle L Templeton; Mathew S Maurer; Yoshifumi Naka; Hiroo Takayama; Donna M Mancini; P Christian Schulze
Journal:  J Card Fail       Date:  2014-02-22       Impact factor: 5.712

3.  Assessment of Wrist Function After Simulated Total Wrist Arthrodesis: A Comparison of 6 Wrist Positions.

Authors:  Richard M Hinds; Eitan Melamed; April O'Connell; Francoise Cherry; Monica Seu; John T Capo
Journal:  Hand (N Y)       Date:  2016-02-02

Review 4.  Outcomes Following Replantation/Revascularization in the Hand.

Authors:  Hoyune E Cho; Sandra V Kotsis; Kevin C Chung
Journal:  Hand Clin       Date:  2019-05       Impact factor: 1.907

5.  Contribution of functional parameters to patient-rated outcomes after surgical treatment of distal radius fractures.

Authors:  Melissa J Shauver; Kate Wan-Chu Chang; Kevin C Chung
Journal:  J Hand Surg Am       Date:  2014-01-18       Impact factor: 2.230

Review 6.  [Grip strength measurement : Significance and boundaries].

Authors:  P Hahn; C Spies; F Unglaub; M Mühldorfer-Fodor
Journal:  Orthopade       Date:  2018-03       Impact factor: 1.087

7.  Time-Dependent Recovery of Outcome Parameters in Ulnar Shortening for Positive Ulnar Variance: A Prospective Case Series.

Authors:  Gernot Schmidle; Tobias Kastenberger; Rohit Arora
Journal:  Hand (N Y)       Date:  2017-04-09

8.  Association Between Maximal Bench Press Strength and Isometric Handgrip Strength Among Breast Cancer Survivors.

Authors:  Benjamin H Rogers; Justin C Brown; David R Gater; Kathryn H Schmitz
Journal:  Arch Phys Med Rehabil       Date:  2016-08-16       Impact factor: 3.966

9.  Comparison of the Grip Strength Using the Martin-Vigorimeter and the JAMAR-Dynamometer: Establishment of Normal Values.

Authors:  Sina Neumann; Sebastian Kwisda; Christian Krettek; Ralph Gaulke
Journal:  In Vivo       Date:  2017 Sep-Oct       Impact factor: 2.155

10.  Surgical fixation compared with cast immobilisation for adults with a bicortical fracture of the scaphoid waist: the SWIFFT RCT.

Authors:  Joseph Dias; Stephen Brealey; Liz Cook; Caroline Fairhurst; Sebastian Hinde; Paul Leighton; Surabhi Choudhary; Matthew Costa; Catherine Hewitt; Stephen Hodgson; Laura Jefferson; Kanagaratnam Jeyapalan; Ada Keding; Matthew Northgraves; Jared Palmer; Amar Rangan; Gerry Richardson; Nicholas Taub; Garry Tew; John Thompson; David Torgerson
Journal:  Health Technol Assess       Date:  2020-10       Impact factor: 4.014

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.