Literature DB >> 2310028

Patient variables and the subarachnoid spread of hyperbaric bupivacaine in the term parturient.

M C Norris1.   

Abstract

To determine if age, height, weight, body mass index, or vertebral column length significantly influence the distribution of sensory analgesia or anesthesia after subarachnoid injection of hyperbaric bupivacaine, 52 women presenting for cesarean section were studied. All received 15 mg hyperbaric bupivacaine via subarachnoid injection at L-2 or L-3. Fifteen minutes after injection, while the women lay supine on a horizontal operating table, the maximum cephalad extent of sensory analgesia (loss of sensation of sharpness to pin prick) and anesthesia (loss of sensation of light touch) was determined. Age (20-42 yr), height (146.9-174.0 cm), weight (55.5-136.4 kg), body mass index (19.2-50.0 kg/m2), and vertebral column length (49.6-67.0 cm) did not correlate with the spread of sensory blockade. In conclusion, in parturients of age, height, weight, body mass index, and vertebral column length within the aforementioned ranges, it is not necessary to vary the dose of injected hyperbaric bupivacaine with changes in any of the patient variables studied.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2310028     DOI: 10.1097/00000542-199003000-00015

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  18 in total

1.  The relationship between symphysis-fundal height and intravenous ephedrine dose in spinal anesthesia for elective cesarean section.

Authors:  Sung Hee Chung; Hyeon Jeong Yang; Jong-Yeon Lee; Kum-Hee Chung; Duk-Hee Chun; Byeong-Kuk Kim
Journal:  Korean J Anesthesiol       Date:  2010-09-20

2.  Relationship of abdominal circumference and trunk length with spinal anesthesia level in the term parturient.

Authors:  Yi-Hui Lee; Yi-Chia Wang; Man-Ling Wang; Pei-Lin Lin; Chi-Hsiang Huang; Hui-Hsun Huang
Journal:  J Anesth       Date:  2013-11-26       Impact factor: 2.078

Review 3.  A Review of the Impact of Obstetric Anesthesia on Maternal and Neonatal Outcomes.

Authors:  Grace Lim; Francesca L Facco; Naveen Nathan; Jonathan H Waters; Cynthia A Wong; Holger K Eltzschig
Journal:  Anesthesiology       Date:  2018-07       Impact factor: 7.892

4.  Spinal anaesthesia for caesarean section after Harrington instrumentation.

Authors:  K Kardash; B W King; S Datta
Journal:  Can J Anaesth       Date:  1993-07       Impact factor: 5.063

5.  Estimation of the dose of hyperbaric bupivacaine for spinal anaesthesia for emergency caesarean section in an achondroplastic dwarf.

Authors:  Tanvir Samra; Sujata Sharma
Journal:  Indian J Anaesth       Date:  2010-09

Review 6.  Spinal anaesthesia in obstetrics.

Authors:  P Morgan
Journal:  Can J Anaesth       Date:  1995-12       Impact factor: 5.063

7.  [Levobupivacaine for parturients undergoing elective caesarean delivery. A dose-finding investigation].

Authors:  D H Bremerich; S Kuschel; N Fetsch; B Zwissler; C Byhahn; D Meininger
Journal:  Anaesthesist       Date:  2007-08       Impact factor: 1.041

8.  Comparison of Spinal Block Levels between Laboring and Nonlaboring Parturients Using Combined Spinal Epidural Technique with Intrathecal Plain Bupivacaine.

Authors:  Yu-Ying Tang; Jie Zhou; Xiao-Hui Ren; Xue-Mei Lin
Journal:  Anesthesiol Res Pract       Date:  2012-06-20

9.  A tryst with a dysmorphic parturient with congenital syphilis.

Authors:  Madhuri S Kurdi; Kaushic A Theerth; Jagadish G Sutagatti; Ashwini Halesh
Journal:  Indian J Anaesth       Date:  2015-03

10.  Comparison of fractionated dose versus bolus dose injection in spinal anaesthesia for patients undergoing elective caesarean section: A randomised, double-blind study.

Authors:  Jigisha Prahaladray Badheka; Vrinda Pravinbhai Oza; Ashutosh Vyas; Deepika Baria; Poonam Nehra; Thomas Babu
Journal:  Indian J Anaesth       Date:  2017-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.