Literature DB >> 23096208

Unenhanced MR angiography of renal arteries: 51 patients.

Chadi Braidy1, Iskandar Daou, Abdoulay Dione Diop, Omar Helweh, Cristian Gageanu, Louis Boyer, Pascal Chabrot.   

Abstract

OBJECTIVE: The purpose of this research was to assess the feasibility and performance of an unenhanced 3D balanced steady-state free precession (SSFP) sequence, compared with contrast-enhanced MR angiography (CEMRA), which is the reference standard to detect and quantify renal artery stenoses (RAS). SUBJECTS AND METHODS: Fifty-one patients were included in this prospective study. Balanced SSFP sequence (Native) and CEMRA were performed using a 1.5-T magnet. Signal quality and stenosis grade were assessed per segment for renal arteries and for ostia of celiac trunk and superior mesenteric artery (SMA). We compared signal quality of Native and CEMRA. Sensitivity, specificity, negative predictive value (NPV), and accuracy were also calculated.
RESULTS: Evaluation involved 114 renal arteries, 51 celiac trunks, and 51 SMAs. By use of CEMRA, 20 significant stenoses were found for renal arteries, 10 stenoses and three occlusions for celiac trunk, and three stenoses for SMA. At artery-by-artery analysis, sensitivity, specificity, accuracy, and NPV of the balanced SSFP sequence in detecting stenosis were respectively 85%, 96%, 94%, and 96% for renal arteries; 100%, 97%, 98%, and 100% for celiac trunk; and 100%, 100%, 100%, and 100% for SMA. No significant difference of signal quality was found for the entire examination and for the different segments evaluated except for hilar and intrarenal branches, which showed better signal quality on balanced SSFP sequence.
CONCLUSION: The NPV results in our study suggest that unenhanced balanced SSFP MR angiography can be the first-choice imaging method to exclude RAS in patients at high risk of nephrogenic systemic fibrosis. However, when stenosis is found, other imaging modalities are necessary for better estimation.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23096208     DOI: 10.2214/AJR.12.8513

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  9 in total

Review 1.  Noncontrast MR angiography: An update.

Authors:  Robert R Edelman; Ioannis Koktzoglou
Journal:  J Magn Reson Imaging       Date:  2018-12-19       Impact factor: 4.813

2.  Non-contrast renal MRA using multi-shot gradient echo EPI at 3-T MRI.

Authors:  Kosuke Morita; Takeshi Nakaura; Masami Yoneyama; Yasunori Nagayama; Masafumi Kidoh; Hiroyuki Uetani; Osamu Ikeda; Yasuyuki Yamashita; Toshinori Hirai
Journal:  Eur Radiol       Date:  2021-01-21       Impact factor: 5.315

3.  Non-contrast MR angiography using three-dimensional balanced steady-state free-precession imaging for evaluation of stenosis in the celiac trunk and superior mesenteric artery: a preliminary comparative study with computed tomography angiography.

Authors:  Patricia P Cardia; Thiago J Penachim; Adilson Prando; Ulysses S Torres; Giuseppe D'Ippólito
Journal:  Br J Radiol       Date:  2017-06-07       Impact factor: 3.039

4.  Non-contrast MR angiography versus contrast enhanced MR angiography for detection of renal artery stenosis: a comparative analysis in 400 renal arteries.

Authors:  Hira Lal; Rani Kunti Randhir Singh; Priyank Yadav; Ankusha Yadav; Dharmendra Bhadauria; Anuradha Singh
Journal:  Abdom Radiol (NY)       Date:  2020-11-02

5.  Ultra-high-field RF coil development for evaluating upper extremity imaging applications.

Authors:  Shailesh B Raval; Tiejun Zhao; Narayanan Krishnamurthy; Tales Santini; Cynthia Britton; Vijay S Gorantla; Tamer S Ibrahim
Journal:  NMR Biomed       Date:  2016-11-03       Impact factor: 4.044

6.  Accuracy of unenhanced magnetic resonance angiography for the assessment of renal artery stenosis.

Authors:  Carmen Sebastià; Alejandro D Sotomayor; Blanca Paño; Rafael Salvador; Marta Burrel; Albert Botey; Carlos Nicolau
Journal:  Eur J Radiol Open       Date:  2016-08-04

7.  Ultra-high field upper extremity peripheral nerve and non-contrast enhanced vascular imaging.

Authors:  Shailesh B Raval; Cynthia A Britton; Tiejun Zhao; Narayanan Krishnamurthy; Tales Santini; Vijay S Gorantla; Tamer S Ibrahim
Journal:  PLoS One       Date:  2017-06-29       Impact factor: 3.240

8.  Successful Depressor Effect Concomitant with Complete Normalization of High Renin and Aldosterone Profile by Percutaneous Transluminal Renal Angioplasty in a Patient with Acute Exacerbated Heart Failure with Preserved Ejection Fraction.

Authors:  Yosuke Takamiya; Keisuke Okamura; Kazuyuki Shirai; Hidenori Urata
Journal:  Am J Case Rep       Date:  2019-11-16

9.  Magnetic resonance imaging with gradient sound respiration guide.

Authors:  Naoharu Kobayashi
Journal:  PLoS One       Date:  2021-07-19       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.