Literature DB >> 23092989

Biomechanical finite element analysis of small diameter and short dental implants: extensive study of commercial implants.

Christoph Bourauel1, Maria Aitlahrach, Friedhelm Heinemann, Istabrak Hasan.   

Abstract

In recent years, mini and short dental implants have become increasingly popular as treatment alternatives for patients in whom the bone is unsuitable for a standard implant. As yet, no detailed scientific analysis of the mechanical and biomechanical impact of the reduced diameter and length of these implants has been published. We analysed 21 commercially available implants (13 mini, eight short) with respect to material behaviour and load transfer to the alveolar bone, using finite element (FE) analysis. Following μCT scanning and geometry reconstruction, FE models of mini implants and short implants were inserted into idealised bone segments. Mini implants were analysed in the anterior mandibular jaw region at a force of 150 N under immediate loading, using a contact analysis in the FE software package Marc Mentat 2007. Short implants were inserted in posterior bone segments and analysed in the osseointegrated state at an occlusal force of 300 N. Von Mises stresses (up to 1150 MPa) in mini implants partly exceeded the ultimate strength. Implant diameter and geometry had a pronounced effect on stresses in the cortical plate (up to 266 MPa). Strains in spongy bone and stresses in cortical bone around short implants were markedly increased compared to those in standard implants. An increased risk of bone damage or implant failure may be assumed in critical clinical situations.

Entities:  

Mesh:

Year:  2012        PMID: 23092989     DOI: 10.1515/bmt-2011-0047

Source DB:  PubMed          Journal:  Biomed Tech (Berl)        ISSN: 0013-5585            Impact factor:   1.411


  9 in total

1.  Influence of implant number, length, and tilting degree on stress distribution in atrophic maxilla: a finite element study.

Authors:  Zeynep Gümrükçü; Yavuz Tolga Korkmaz
Journal:  Med Biol Eng Comput       Date:  2017-11-09       Impact factor: 2.602

2.  Influence of Implant Design (Cylindrical and Conical) in the Load Transfer Surrounding Long (13mm) and Short (7mm) Length Implants: A Photoelastic Analysis.

Authors:  Sergio Alexandre Gehrke; Victor Lourenço Frugis; Jamil Awad Shibli; Maria Piedad Ramirez Fernandez; José Eduardo Maté Sánchez de Val; José Luis Calvo Girardo; Silvio Taschieri; Stefano Corbella
Journal:  Open Dent J       Date:  2016-09-30

3.  A Comparative Analysis of Implants Presenting Different Diameters: Extra-Narrow, Narrow and Conventional.

Authors:  Henrique Tuzzolo Neto; Alessandra Sayuri Tuzita; Sérgio Alexandre Gehrke; Renata de Vasconcellos Moura; Márcio Zaffalon Casati; Alfredo Mikail Melo Mesquita
Journal:  Materials (Basel)       Date:  2020-04-17       Impact factor: 3.623

4.  Biomechanical finite element analysis of short-implant-supported, 3-unit, fixed CAD/CAM prostheses in the posterior mandible.

Authors:  Lana Zupancic Cepic; Martin Frank; Andreas Reisinger; Dieter Pahr; Werner Zechner; Andreas Schedle
Journal:  Int J Implant Dent       Date:  2022-02-11

5.  Effect of Number and Location on Stress Distribution of Mini Dental Implant-Assisted Mandibular Kennedy Class I Removable Partial Denture: Three-Dimensional Finite Element Analysis.

Authors:  Wissanee Jia-Mahasap; Chaiy Rungsiyakull; Wipahatpong Bumrungsiri; Natthaphorn Sirisereephap; Pimduen Rungsiyakull
Journal:  Int J Dent       Date:  2022-03-26

6.  Does the Length of Mini Dental Implants Affect Their Resistance to Failure by Overloading?

Authors:  Rafif Alshenaiber; Nick Silikas; Craig Barclay
Journal:  Dent J (Basel)       Date:  2022-07-01

7.  Biomechanics and load resistance of short dental implants: a review of the literature.

Authors:  Istabrak Hasan; Christoph Bourauel; Torsten Mundt; Friedhelm Heinemann
Journal:  ISRN Dent       Date:  2013-05-08

8.  Osteoblast integration of dental implant materials after challenge by sub-gingival pathogens: a co-culture study in vitro.

Authors:  Bingran Zhao; Henny C van der Mei; Minie Rustema-Abbing; Henk J Busscher; Yijin Ren
Journal:  Int J Oral Sci       Date:  2015-12-18       Impact factor: 6.344

9.  Influence of short implants geometry on primary stability.

Authors:  J González-Serrano; P Molinero-Mourelle; B Pardal-Peláez; L-M Sáez-Alcaide; R Ortega; J López-Quiles
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2018-09-01
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.