Passive marker tracking via phase-only cross correlation (POCC) for MR-guided needle interventions: initial in vivo experience.

Axel Joachim Krafft1, Patrik Zamecnik, Florian Maier, André de Oliveira, Peter Hallscheidt, Heinz-Peter Schlemmer, Michael Bock.   

Abstract

PURPOSE: In this work, a passive tracking sequence employing a phase-only cross correlation (POCC) algorithm was studied with a focus on the in vivo applicability of the technique. Therefore, MR-guided needle interventions were performed in a phantom and two animal experiments.
METHODS: The targeting accuracy was quantified in an agarose phantom with 15 fiducials. For each fiducial, the distance between needle trajectory and target point was measured. In a first animal experiment at 3 T, the prostate of a pig was punctured under POCC guidance. Second, POCC-based tracking was performed during a laser-induced thermal therapy procedure in peripheral porcine muscle tissue at 1.5 T.
RESULTS: In the phantom experiment, the 15 fiducials were penetrated with a mean accuracy of 1.5 ± 0.9 mm (mean duration for one puncture about 2 min). In the first animal experiment, the center of the pig's right prostatic lobe was accurately punctured within 15 min. In the second, targeting and insertion of the needle could be performed within 5 min and a thermal lesion was successfully created.
CONCLUSION: Our initial experience with the POCC-based tracking sequence indicates that this technique has the potential as an accurate and versatile tool for in vivo MR-guided needle interventions.
Copyright © 2012 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Interventional magnetic resonance imaging; Interventional radiology; MR-guided interventional procedures; MR-guided needle intervention; MR-guided prostate biopsy

Mesh:

Year:  2012        PMID: 23084541     DOI: 10.1016/j.ejmp.2012.09.002

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  5 in total

1.  An MR-compatible stereoscopic in-room 3D display for MR-guided interventions.

Authors:  Alexander Brunner; Jens Groebner; Reiner Umathum; Florian Maier; Wolfhard Semmler; Michael Bock
Journal:  MAGMA       Date:  2013-12-10       Impact factor: 2.310

2.  Simultaneous slice excitation for accelerated passive marker tracking via phase-only cross correlation (POCC) in MR-guided needle interventions.

Authors:  Andreas Reichert; Michael Bock; Simon Reiss; Christiaan G Overduin; Jurgen J Fütterer; Axel Joachim Krafft
Journal:  MAGMA       Date:  2018-09-06       Impact factor: 2.310

3.  Autonomous real-time interventional scan plane control with a 3-D shape-sensing needle.

Authors:  Santhi Elayaperumal; Juan Camilo Plata; Andrew B Holbrook; Yong-Lae Park; Kim Butts Pauly; Bruce L Daniel; Mark R Cutkosky
Journal:  IEEE Trans Med Imaging       Date:  2014-06-23       Impact factor: 10.048

4.  GantryMate: A Modular MR-Compatible Assistance System for MR-Guided Needle Interventions.

Authors:  Andreas Reichert; Michael Bock; Michael Vogele; Axel Joachim Krafft
Journal:  Tomography       Date:  2019-06

5.  Evaluation of cine imaging during multileaf collimator and gantry motion for real-time magnetic resonance guided radiation therapy.

Authors:  Jerrold E Kielbasa; Sanford L Meeks; Patrick Kelly; Twyla R Willoughby; Omar Zeidan; Amish P Shah
Journal:  J Appl Clin Med Phys       Date:  2020-11-23       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.