High temporal resolution in vivo blood oximetry via projection-based T2 measurement.

Varsha Jain1, Jeremy Magland, Michael Langham, Felix W Wehrli.   

Abstract

Measuring venous oxygen saturation (HbO2) in large blood vessels can provide important information about oxygen delivery and its consumption in vital organs. Quantification of blood's T2 value via MR can be utilized to determine HbO2 noninvasively. We propose a fast method for in vivo blood T2 quantification via computing the complex difference of velocity-encoded projections. As blood flows continuously, its signal can be robustly isolated from the surrounding tissue by computing the complex difference of two central k-space lines with different velocity encodings. This resultant signal can then be measured as a function of echo time for rapidly quantifying T2 of blood. We applied the method to quantify HbO2 in three cerebral veins at rest and in one of the veins in response to hypercapnia. Average HbO2 measurements in superior sagittal sinus (SSS), straight sinus and internal jugular vein in the group were 63 ± 3%, 68 ± 4% and 65 ± 4%, respectively. Average HbO2 values in SSS during baseline, hypercapnia, and recovery were 63 ± 2%, 79 ± 5%, and 61 ± 3%, respectively. When compared with standard T2 quantification techniques, the proposed method is fast, reliable, and robust against partial volume effects.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Keywords:  MR oximetry; T2 quantification; blood oxygenation

Mesh:

Year:  2012        PMID: 23081759      PMCID: PMC4717474          DOI: 10.1002/mrm.24519

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  22 in total

1.  MRI susceptometry: image-based measurement of absolute susceptibility of MR contrast agents and human blood.

Authors:  R M Weisskoff; S Kiihne
Journal:  Magn Reson Med       Date:  1992-04       Impact factor: 4.668

2.  MR susceptometry for measuring global brain oxygen extraction.

Authors:  María A Fernández-Seara; Aranee Techawiboonwong; John A Detre; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2006-05       Impact factor: 4.668

3.  1991 I.I. Rabi Award. Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T.

Authors:  G A Wright; B S Hu; A Macovski
Journal:  J Magn Reson Imaging       Date:  1991 May-Jun       Impact factor: 4.813

4.  Partial volume effects on vascular T2 measurements.

Authors:  J A Stainsby; G A Wright
Journal:  Magn Reson Med       Date:  1998-09       Impact factor: 4.668

5.  Rapid magnetic resonance measurement of global cerebral metabolic rate of oxygen consumption in humans during rest and hypercapnia.

Authors:  Varsha Jain; Michael C Langham; Thomas F Floyd; Gaurav Jain; Jeremy F Magland; Felix W Wehrli
Journal:  J Cereb Blood Flow Metab       Date:  2011-04-20       Impact factor: 6.200

6.  Time-resolved absolute velocity quantification with projections.

Authors:  Michael C Langham; Varsha Jain; Jeremy F Magland; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2010-07-30       Impact factor: 4.668

7.  Cerebral blood flow and metabolism in patients with silent brain infarction: occult misery perfusion in the cerebral cortex.

Authors:  H Nakane; S Ibayashi; K Fujii; S Sadoshima; K Irie; T Kitazono; M Fujishima
Journal:  J Neurol Neurosurg Psychiatry       Date:  1998-09       Impact factor: 10.154

8.  Quantitative evaluation of oxygenation in venous vessels using T2-Relaxation-Under-Spin-Tagging MRI.

Authors:  Hanzhang Lu; Yulin Ge
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

9.  MRI-based blood oxygen saturation measurements in infants and children with congenital heart disease.

Authors:  Lynne E Nield; Xiuling Qi; Shi-Joon Yoo; Emanuela R Valsangiacomo; Lisa K Hornberger; Graham A Wright
Journal:  Pediatr Radiol       Date:  2002-04-16

10.  Human whole blood T2 relaxometry at 3 Tesla.

Authors:  Jean J Chen; G Bruce Pike
Journal:  Magn Reson Med       Date:  2009-02       Impact factor: 4.668

View more
  27 in total

1.  Correction and optimization of a T2-based approach to map blood oxygenation in small cerebral veins.

Authors:  Lisa C Krishnamurthy; Deng Mao; Kevin S King; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2015-04-04       Impact factor: 4.668

2.  Method for rapid MRI quantification of global cerebral metabolic rate of oxygen.

Authors:  Suliman Barhoum; Michael C Langham; Jeremy F Magland; Zachary B Rodgers; Cheng Li; Chamith S Rajapakse; Felix W Wehrli
Journal:  J Cereb Blood Flow Metab       Date:  2015-05-13       Impact factor: 6.200

3.  Quantification of whole-brain oxygenation extraction fraction and cerebral metabolic rate of oxygen consumption in adults with sickle cell anemia using individual T2 -based oxygenation calibrations.

Authors:  Wenbo Li; Xiang Xu; Peiying Liu; John J Strouse; James F Casella; Hanzhang Lu; Peter C M van Zijl; Qin Qin
Journal:  Magn Reson Med       Date:  2019-09-04       Impact factor: 4.668

4.  High-speed whole-brain oximetry by golden-angle radial MRI.

Authors:  Wen Cao; Yulin V Chang; Erin K Englund; Hee Kwon Song; Suliman Barhoum; Zachary B Rodgers; Michael C Langham; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2017-03-25       Impact factor: 4.668

5.  Quantitative theory for the transverse relaxation time of blood water.

Authors:  Wenbo Li; Peter C M van Zijl
Journal:  NMR Biomed       Date:  2020-02-05       Impact factor: 4.044

Review 6.  MRI-based methods for quantification of the cerebral metabolic rate of oxygen.

Authors:  Zachary B Rodgers; John A Detre; Felix W Wehrli
Journal:  J Cereb Blood Flow Metab       Date:  2016-04-18       Impact factor: 6.200

7.  Cross-vendor harmonization of T2 -relaxation-under-spin-tagging (TRUST) MRI for the assessment of cerebral venous oxygenation.

Authors:  Dengrong Jiang; Peiying Liu; Yang Li; Deng Mao; Cuimei Xu; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2018-01-25       Impact factor: 4.668

8.  Separation of cellular and BOLD contributions to T2* signal relaxation.

Authors:  Xialing Ulrich; Dmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2015-03-10       Impact factor: 4.668

9.  In vivo whole-blood T2 versus HbO2 calibration by modulating blood oxygenation level in the femoral vein through intermittent cuff occlusion.

Authors:  Michael C Langham; Ana E Rodríguez-Soto; Nadav Schwartz; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2017-09-03       Impact factor: 4.668

Review 10.  Time-resolved MRI oximetry for quantifying CMRO(2) and vascular reactivity.

Authors:  Felix W Wehrli; Zachary B Rodgers; Varsha Jain; Michael C Langham; Cheng Li; Daniel J Licht; Jeremy Magland
Journal:  Acad Radiol       Date:  2014-02       Impact factor: 3.173