Performances of four fourth-generation human immunodeficiency virus-1 screening assays.

Eun Young Song1, Mina Hur, Eun Youn Roh, Myoung Hee Park, Hee-Won Moon, Yeo Min Yun.   

Abstract

Fourth-generation human immunodeficiency virus-1 (HIV-1) screening assays have improved sensitivity, but vary in performance characteristics. The purpose of this study was to evaluate four different fourth-generation HIV-1 assays. These assays included the AxSYM HIV Ag/Ab Combo (Abbott diagnostics, Delkenheim, Germany), ARCHITECT HIV Ag/Ab Combo (Abbott), Elecsys 2010 HIV Combi (Roche Diagnostics GmbH, Mannheim, Germany), and Elecsys HIV Combi PT (Roche). A total of 1,306 samples that included 1,225 clinical samples and 81 samples consisting of seroconversion panels, an HIV-1 p24 antigen sensitivity panel, and dilution series of HIV-1 lysates and HIV-1 antibodies were tested. All of the assays had sensitivities of 100% on clinical samples. The specificities of the AxSYM, ARCHITECT, Elecsys 2010 HIV Combi, and Elecsys HIV Combi PT were 99.6, 99.6, 99.0, and 99.5%, respectively. Of the 81 samples with different levels of HIV antigen or antibody and/or subtypes, Elecsys HIV Combi PT and ARCHITECT HIV Ag/Ab Combo showed better analytical sensitivities than the other two assays. In summary, the performance characteristics of AxSYM, ARCHITECT, and Elecsys HIV Combi PT were comparable and satisfactory for clinical samples. ARCHITECT HIV Ag/Ab Combo and Elecsys HIV Combi PT have the higher analytical sensitivities, and would be preferable for reducing the window period.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23080491     DOI: 10.1002/jmv.23423

Source DB:  PubMed          Journal:  J Med Virol        ISSN: 0146-6615            Impact factor:   2.327


  12 in total

1.  A retrospective analysis of the application of the Elecsys® HIV combi PT assay in southern China.

Authors:  Shaocong Liang; Guihua Deng; Shaosong Zhou; Jing Zeng; Weiqing Tan; Xiaopeng Yuan
Journal:  J Clin Lab Anal       Date:  2017-06-26       Impact factor: 2.352

2.  The Performance of the Abbott i2000 for Measuring Serum Markers of Infectious Diseases.

Authors:  Linchuan Wang; Wei Chen; Yan Yu
Journal:  J Clin Lab Anal       Date:  2016-06-15       Impact factor: 2.352

3.  Clinical application evaluation of two fourth-generation human immunodeficiency virus (HIV) screening assays in West China Hospital.

Authors:  Yongming Liu; Dongdong Li; Tingting Wang; Kening Yan; Siyuan Zhu; Tingfu Yang; Lan Luo; Chuanmin Tao
Journal:  J Clin Lab Anal       Date:  2014-05-05       Impact factor: 2.352

4.  A signal-to-cutoff ratio in the Abbott architect HIV Ag/Ab Combo assay that predicts subsequent confirmation of HIV-1 infection in a low-prevalence setting.

Authors:  Tomas Ostergaard Jensen; Peter Robertson; Ross Whybin; Ian Chambers; Monica Lahra; William Rawlinson; Jeffrey John Post
Journal:  J Clin Microbiol       Date:  2015-02-11       Impact factor: 5.948

5.  Prolonged second diagnostic window for human immunodeficiency virus type 1 in a fourth-generation immunoassay: are alternative testing strategies required?

Authors:  C R Robert George; Peter W Robertson; M Josephine Lusk; Ross Whybin; William Rawlinson
Journal:  J Clin Microbiol       Date:  2014-09-10       Impact factor: 5.948

6.  Evaluation of the Bio-Rad Geenius HIV 1/2 Confirmation Assay as an Alternative to Western Blot in the Korean Population: A Multi-Center Study.

Authors:  Hee-Won Moon; Hee Jin Huh; Gwi Young Oh; Sang Gon Lee; Anna Lee; Yeo-Min Yun; Mina Hur
Journal:  PLoS One       Date:  2015-09-30       Impact factor: 3.240

7.  Reduction of the HIV seroconversion window period and false positive rate by using ADVIA Centaur HIV antigen/antibody combo assay.

Authors:  Kyunghoon Lee; Hyung-Doo Park; Eun-Suk Kang
Journal:  Ann Lab Med       Date:  2013-10-17       Impact factor: 3.464

8.  Generation of a recombinant Gag virus-like-particle panel for the evaluation of p24 antigen detection by diagnostic HIV tests.

Authors:  Beatrice N Vetter; Vanessa Orlowski; Katrien Fransen; Christoph Niederhauser; Vincent Aubert; Marcel Brandenberger; Diana Ciardo; Günter Dollenmaier; Thomas Klimkait; Stephan Regenass; Patrick Schmid; Volkmar Schottstedt; Franziska Suter-Riniker; Sabine Yerly; Cyril Shah; Jürg Böni; Jörg Schüpbach
Journal:  PLoS One       Date:  2014-10-24       Impact factor: 3.240

9.  Analytical and Clinical Performance Evaluation of the Elecsys HIV combi PT Assay on the cobas e 602 Analyzer for the Diagnosis of Human Immunodeficiency Virus.

Authors:  Denise L Uettwiller-Geiger; Marvin Lessig; Jie An; Tara Barsch; Susan Smith; Sharan Walker; Alexander Riedel; Yi Hao; Amin A Mohammad
Journal:  Am J Clin Pathol       Date:  2019-03-01       Impact factor: 2.493

10.  The evaluation of low cut-off index values of Elecsys® HIV combi PT assay in predicting false-positive results.

Authors:  Zhuoyun Tang; Yu Gou; Keyi Zhang; Zhongyi Zhao; Yinhao Wei; Dongdong Li; Li Chen; Chuanmin Tao
Journal:  J Clin Lab Anal       Date:  2020-08-25       Impact factor: 2.352