Literature DB >> 23077972

Ambulatory blood pressure monitoring: importance of sampling rate and duration--48 versus 24 hours--on the accurate assessment of cardiovascular risk.

Ramón C Hermida1, Diana E Ayala, María J Fontao, Artemio Mojón, José R Fernández.   

Abstract

Independent prospective studies have found that ambulatory blood pressure (BP) monitoring (ABPM) is more closely correlated with target organ damage and cardiovascular disease (CVD) risk than clinic BP measurement. This is based on studies in which BP was sampled every 15-30 min for ≤24 h, without taking into account that reproducibility of any estimated parameter from a time series to be potentially used for CVD risk assessment might depend more on monitoring duration than on sampling rate. Herein, we evaluated the influence of duration (48 vs. 24 h) and sampling rate of BP measurements (form every 20-30 min up to every 2 h) on the prognostic value of ABPM-derived parameters. We prospectively studied 3344 subjects (1718 men/1626 women), 52.6 ± 14.5 yrs of age, during a median follow-up of 5.6 yrs. Those with hypertension at baseline were randomized to ingest all their prescribed hypertension medications upon awakening or ≥1 of them at bedtime. At baseline, BP was measured at 20-min intervals from 07:00 to 23:00 h and at 30-min intervals at night for 48 h, and physical activity was simultaneously monitored every min by wrist actigraphy to accurately derive the awake and asleep BP means. Identical assessment was scheduled annually and more frequently (quarterly) if treatment adjustment was required. ABPM profiles were modified to generate time series of identical 48-h duration but with data sampled at 1- or 2-h intervals, or shorter, i.e., first 24 h, time series with data sampled at the original rate (daytime 20-min intervals/nighttime 30-min intervals). Bland-Altman plots indicated that the range of individual differences in the estimated awake and asleep systolic (SBP) and diastolic BP (DBP) means between the original and modified ABPM profiles was up to 3-fold smaller for data sampled every 1 h for 48 h than for data sampled every 20-30 min for the first 24 h. Reduction of ABPM duration to just 24 h resulted in error of the estimated asleep SBP mean, the most significant prognostic marker of CVD events, in the range of -21.4 to +23.9 mm Hg. Cox proportional-hazard analyses adjusted for sex, age, diabetes, anemia, and chronic kidney disease revealed comparable hazard ratios (HRs) for mean BP values and sleep-time relative BP decline derived from the original complete 48-h ABPM profiles and those modified to simulate a sampling rate of one BP measurement every 1 or 2 h. The HRs, however, were markedly overestimated for SBP and underestimated for DBP when the duration of ABPM was reduced from 48 to only 24 h. This study on subjects evaluated prospectively by 48-h ABPM documents that reproducibility in the estimates of prognostic ABPM-derived parameters depends markedly on duration of monitoring, and only to a lesser extent on sampling rate. The HR of CVD events associated with increased ambulatory BP is poorly estimated by relying on 24-h ABPM, indicating ABPM for only 24 h may be insufficient for proper diagnosis of hypertension, identification of dipping status, evaluation of treatment efficacy, and, most important, CVD risk stratification.

Entities:  

Mesh:

Year:  2012        PMID: 23077972     DOI: 10.3109/07420528.2012.701457

Source DB:  PubMed          Journal:  Chronobiol Int        ISSN: 0742-0528            Impact factor:   2.877


  17 in total

Review 1.  Chronotherapeutics of conventional blood pressure-lowering medications: simple, low-cost means of improving management and treatment outcomes of hypertensive-related disorders.

Authors:  Ramón C Hermida; Diana E Ayala; Michael H Smolensky; José R Fernández; Artemio Mojón; Juan J Crespo; María T Ríos; Ana Moyá; Francesco Portaluppi
Journal:  Curr Hypertens Rep       Date:  2014-02       Impact factor: 5.369

Review 2.  Chronotherapy improves blood pressure control and reduces vascular risk in CKD.

Authors:  Ramón C Hermida; Diana E Ayala; Michael H Smolensky; Artemio Mojón; José R Fernández; Juan J Crespo; Ana Moyá; María T Ríos; Francesco Portaluppi
Journal:  Nat Rev Nephrol       Date:  2013-04-23       Impact factor: 28.314

Review 3.  Sleep-time ambulatory blood pressure as a novel therapeutic target for cardiovascular risk reduction.

Authors:  R C Hermida; D E Ayala; A Mojón; M H Smolensky; F Portaluppi; J R Fernández
Journal:  J Hum Hypertens       Date:  2014-02-06       Impact factor: 3.012

4.  Bedtime ingestion of hypertension medications reduces the risk of new-onset type 2 diabetes: a randomised controlled trial.

Authors:  Ramón C Hermida; Diana E Ayala; Artemio Mojón; José R Fernández
Journal:  Diabetologia       Date:  2015-09-23       Impact factor: 10.122

5.  Sleep-time BP: prognostic marker of type 2 diabetes and therapeutic target for prevention.

Authors:  Ramón C Hermida; Diana E Ayala; Artemio Mojón; José R Fernández
Journal:  Diabetologia       Date:  2015-09-23       Impact factor: 10.122

6.  Use of ambulatory blood pressure monitoring to guide hypertensive therapy.

Authors:  Amita Singh; Eugenia Gianos; Arthur Schwartzbard; Henry Black; Howard Weintraub
Journal:  Curr Treat Options Cardiovasc Med       Date:  2013-12

Review 7.  Around-the-clock ambulatory blood pressure monitoring is required to properly diagnose resistant hypertension and assess associated vascular risk.

Authors:  Ramón C Hermida; Diana E Ayala; María T Ríos; José R Fernández; Artemio Mojón; Michael H Smolensky
Journal:  Curr Hypertens Rep       Date:  2014-07       Impact factor: 5.369

Review 8.  The complex relationship between CKD and ambulatory blood pressure patterns.

Authors:  Arjun D Sinha; Rajiv Agarwal
Journal:  Adv Chronic Kidney Dis       Date:  2015-03       Impact factor: 3.620

Review 9.  Chronotherapy with conventional blood pressure medications improves management of hypertension and reduces cardiovascular and stroke risks.

Authors:  Ramón C Hermida; Diana E Ayala; Michael H Smolensky; José R Fernández; Artemio Mojón; Francesco Portaluppi
Journal:  Hypertens Res       Date:  2015-12-10       Impact factor: 3.872

10.  Pulse Arrival Time Based Cuff-Less and 24-H Wearable Blood Pressure Monitoring and its Diagnostic Value in Hypertension.

Authors:  Yali Zheng; Carmen C Y Poon; Bryan P Yan; James Y W Lau
Journal:  J Med Syst       Date:  2016-07-22       Impact factor: 4.460

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.