Online geometric calibration of cone-beam computed tomography for arbitrary imaging objects.

Yuanzheng Meng1, Hui Gong, Xiaoquan Yang.   

Abstract

A novel online method based on the symmetry property of the sum of projections (SOP) is proposed to obtain the geometric parameters in cone-beam computed tomography (CBCT). This method requires no calibration phantom and can be used in circular trajectory CBCT with arbitrary cone angles. An objective function is deduced to illustrate the dependence of the symmetry of SOP on geometric parameters, which will converge to its minimum when the geometric parameters achieve their true values. Thus, by minimizing the objective function, we can obtain the geometric parameters for image reconstruction. To validate this method, numerical phantom studies with different noise levels are simulated. The results show that our method is insensitive to the noise and can determine the skew (in-plane rotation angle of the detector), the roll (rotation angle around the projection of the rotation axis on the detector), and the rotation axis with high accuracy, while the mid-plane and source-to-detector distance will be obtained with slightly lower accuracy. However, our simulation studies validate that the errors of the latter two parameters brought by our method will hardly degrade the quality of reconstructed images. The small animal studies show that our method is able to deal with arbitrary imaging objects. In addition, the results of the reconstructed images in different slices demonstrate that we have achieved comparable image quality in the reconstructions as some offline methods.

Entities:  

Mesh:

Year:  2012        PMID: 23076032     DOI: 10.1109/TMI.2012.2224360

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  6 in total

1.  Tomosynthesis implementation with adaptive online calibration on clinical C-arm systems.

Authors:  Khanlian Chung; Lothar R Schad; Frank G Zöllner
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-05-08       Impact factor: 2.924

2.  Influence of multi-angle input of intraoperative fluoroscopic images on the spatial positioning accuracy of the C-arm calibration-based algorithm of a CAOS system.

Authors:  Xiangqian Chen; Yu Wang; Gang Zhu; Weijun Zhang; Gang Zhou; Yubo Fan
Journal:  Med Biol Eng Comput       Date:  2020-01-09       Impact factor: 2.602

3.  Self-calibration of cone-beam CT geometry using 3D-2D image registration.

Authors:  S Ouadah; J W Stayman; G J Gang; T Ehtiati; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2016-03-10       Impact factor: 3.609

4.  Angle prediction model when the imaging plane is tilted about z-axis.

Authors:  Zheng Fang; Bichao Ye; Bingan Yuan; Tingjun Wang; Shuo Zhong; Shunren Li; Jianyi Zheng
Journal:  J Supercomput       Date:  2022-06-08       Impact factor: 2.557

5.  Geometric calibration of a stationary digital breast tomosynthesis system based on distributed carbon nanotube X-ray source arrays.

Authors:  Changhui Jiang; Na Zhang; Juan Gao; Zhanli Hu
Journal:  PLoS One       Date:  2017-11-29       Impact factor: 3.240

6.  A geometric calibration method for the digital chest tomosynthesis with dual-axis scanning geometry.

Authors:  Chia-Hao Chang; Yu-Ching Ni; Syuan-Ya Huang; Ho-Hui Hsieh; Sheng-Pin Tseng; Fan-Pin Tseng
Journal:  PLoS One       Date:  2019-04-25       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.