Literature DB >> 23074201

Structure-function relationship between FDF, FDT, SAP, and scanning laser ophthalmoscopy in glaucoma patients.

Julia Lamparter1, Richard A Russell, Andreas Schulze, Ann-Christin Schuff, Norbert Pfeiffer, Esther M Hoffmann.   

Abstract

PURPOSE: Flicker defined form perimetry (FDF) and frequency doubling technology perimetry (FDT) are alleged to detect glaucoma at an earlier stage than standard automated perimetry (SAP). It is the purpose of this study to investigate the structure-function relationship between FDF, FDT, SAP, and confocal scanning laser ophthalmoscopy (cSLO) in patients with glaucoma.
METHODS: Seventy-six patients with glaucoma were included in the study. Patients were tested with SAP, Matrix-FDT, FDF perimetry, and cSLO. Structure-function relationships between global and sectoral cSLO parameters and global and sectoral mean sensitivity (MS) of SAP, Matrix-FDT, and FDF were calculated using Spearman's rank correlation and linear regression.
RESULTS: Overall, FDF perimetry showed the strongest structure-function relationship (GLOBAL correlation with rim area: 0.44; range of significant sectoral FDF values: 0.23-0.69), followed by FDT (global correlation with rim area: 0.35; range of significant sectoral FDT values: 0.25-0.60). SAP presented with the weakest structure-function relationship and fewer statistically significant results (global correlation with rim volume: 0.32; range of significant sectoral SAP values: 0.23-0.58). Sector-by-sector, the structure-function relationship was greatest in the superotemporal and inferotemporal regions. Weakest correlations were found in the inferonasal and nasal sectors.
CONCLUSIONS: The correlation between structure and function is stronger in FDF and FDT compared with SAP. Correlations are strongest in temporal areas where glaucomatous damage tends to occur first. A better understanding of the structure-function relationship should allow for improved detection and management of glaucoma patients.

Entities:  

Mesh:

Year:  2012        PMID: 23074201     DOI: 10.1167/iovs.12-10892

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  20 in total

1.  Characteristic correlations of the structure-function relationship in different glaucomatous disc types.

Authors:  Kazuko Omodaka; Naoko Takada; Takuhiro Yamaguchi; Hidetoshi Takahashi; Makoto Araie; Toru Nakazawa
Journal:  Jpn J Ophthalmol       Date:  2015-04-11       Impact factor: 2.447

2.  [Flicker and conventional perimetry in comparison with structural changes in glaucoma].

Authors:  F Dannheim
Journal:  Ophthalmologe       Date:  2013-02       Impact factor: 1.059

Review 3.  [Differentiation of ocular hypertension].

Authors:  E M Hoffmann; J Lamparter
Journal:  Ophthalmologe       Date:  2016-08       Impact factor: 1.059

4.  Structural and Functional Evaluations for the Early Detection of Glaucoma.

Authors:  Katie A Lucy; Gadi Wollstein
Journal:  Expert Rev Ophthalmol       Date:  2016-09-14

5.  Flicker-defined form perimetry in glaucoma patients.

Authors:  Folkert K Horn; Jan Kremers; Christian Y Mardin; Anselm G Jünemann; Werner Adler; Ralf P Tornow
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-12-16       Impact factor: 3.117

6.  Evaluation of pupillary response to light in patients with glaucoma: a study using computerized pupillometry.

Authors:  Alessio Martucci; Massimo Cesareo; Domenico Napoli; Roberto Pietro Sorge; Federico Ricci; Raffaele Mancino; Carlo Nucci
Journal:  Int Ophthalmol       Date:  2014-02-19       Impact factor: 2.031

7.  Comparison of frequency doubling and flicker defined form perimetry in early glaucoma.

Authors:  Folkert K Horn; Vicki Scharch; Christian Y Mardin; Robert Lämmer; Jan Kremers
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-02-17       Impact factor: 3.117

8.  Correlation between early retinal nerve fiber layer loss and visual field loss determined by three different perimetric strategies: white-on-white, frequency-doubling, or flicker-defined form perimetry.

Authors:  Verena Prokosch; Nicole Eter
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-07-30       Impact factor: 3.117

9.  Structure-Function Mapping Using a Three-Dimensional Neuroretinal Rim Parameter Derived From Spectral Domain Optical Coherence Tomography Volume Scans.

Authors:  Ali Riza Cenk Celebi; Elli A Park; Alice Chandra Verticchio Vercellin; Edem Tsikata; Ramon Lee; Eric Shieh; Hussein Antar; Madeline Freeman; Jing Zhang; Christian Que; Huseyin Simavli; Michael McClurkin; Rong Guo; Tobias Elze; Johannes F de Boer; Teresa C Chen
Journal:  Transl Vis Sci Technol       Date:  2021-05-03       Impact factor: 3.283

10.  Standard automated perimetry versus matrix frequency doubling technology perimetry in subjects with ocular hypertension and healthy control subjects.

Authors:  Julia Lamparter; Shakhsanam Aliyeva; Andreas Schulze; Manfred Berres; Norbert Pfeiffer; Esther M Hoffmann
Journal:  PLoS One       Date:  2013-02-28       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.