Fast escape of hydrogen from gas cavities around corroding magnesium implants.

Julia Kuhlmann1, Ivonne Bartsch, Elmar Willbold, Sven Schuchardt, Olaf Holz, Norbert Hort, Daniel Höche, William R Heineman, Frank Witte.   

Abstract

Magnesium materials are of increasing interest in the development of biodegradable implants as they exhibit properties that make them promising candidates. However, the formation of gas cavities after implantation of magnesium alloys has been widely reported in the literature. The composition of the gas and the concentration of its components in these cavities are not known as only a few studies using non-specific techniques were done about 60 years ago. Currently many researchers assume that these cavities contain primarily hydrogen because it is a product of magnesium corrosion in aqueous media. In order to clearly answer this question we implanted rare earth-containing magnesium alloy disks in mice and determined the concentration of hydrogen gas for up to 10 days using an amperometric hydrogen sensor and mass spectrometric measurements. We were able to directly monitor the hydrogen concentration over a period of 10 days and show that the gas cavities contained only a low concentration of hydrogen gas, even shortly after formation of the cavities. This means that hydrogen must be exchanged very quickly after implantation. To confirm these results hydrogen gas was directly injected subcutaneously. Most of the hydrogen gas was found to exchange within 1h after injection. Overall, our results disprove the common misbelief that these cavities mainly contain hydrogen and show how quickly this gas is exchanged with the surrounding tissue.
Copyright © 2012 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Amperometric hydrogen sensor; Biodegradable implants; Gas cavities; Hydrogen; Magnesium alloys

Mesh:

Substances:

Year:  2012        PMID: 23069319     DOI: 10.1016/j.actbio.2012.10.008

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  40 in total

1.  Long-term clinical study and multiscale analysis of in vivo biodegradation mechanism of Mg alloy.

Authors:  Jee-Wook Lee; Hyung-Seop Han; Kyeong-Jin Han; Jimin Park; Hojeong Jeon; Myoung-Ryul Ok; Hyun-Kwang Seok; Jae-Pyoung Ahn; Kyung Eun Lee; Dong-Ho Lee; Seok-Jo Yang; Sung-Youn Cho; Pil-Ryung Cha; Hoon Kwon; Tae-Hyun Nam; Jee Hye Lo Han; Hyoung-Jin Rho; Kang-Sik Lee; Yu-Chan Kim; Diego Mantovani
Journal:  Proc Natl Acad Sci U S A       Date:  2016-01-04       Impact factor: 11.205

2.  A novel multilayer model with controllable mechanical properties for magnesium-based bone plates.

Authors:  Juncen Zhou; Wanru Huang; Qing Li; Zuxin She; Funan Chen; Longqin Li
Journal:  J Mater Sci Mater Med       Date:  2015-03-20       Impact factor: 3.896

3.  Effects of degradable osteosynthesis plates of MgYREZr alloy on cell function of human osteoblasts, fibroblasts and osteosarcoma cells.

Authors:  Hendrik Naujokat; Aydin Gülses; Jörg Wiltfang; Yahya Açil
Journal:  J Mater Sci Mater Med       Date:  2017-07-15       Impact factor: 3.896

4.  Self-powered therapeutic release from conducting polymer/graphene oxide films on magnesium.

Authors:  Kasey Catt; Huaxiu Li; Victor Hoang; Roland Beard; X Tracy Cui
Journal:  Nanomedicine       Date:  2017-05-29       Impact factor: 5.307

5.  Biomechanical characteristics of bioabsorbable magnesium-based (MgYREZr-alloy) interference screws with different threads.

Authors:  Marco Ezechieli; Max Ettinger; Carolin König; Andreas Weizbauer; Patrick Helmecke; Robert Schavan; Arne Lucas; Henning Windhagen; Christoph Becher
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-09-24       Impact factor: 4.342

6.  Poly (3,4-ethylenedioxythiophene) graphene oxide composite coatings for controlling magnesium implant corrosion.

Authors:  Kasey Catt; Huaxiu Li; X Tracy Cui
Journal:  Acta Biomater       Date:  2016-11-17       Impact factor: 8.947

7.  Implant-derived magnesium induces local neuronal production of CGRP to improve bone-fracture healing in rats.

Authors:  Yifeng Zhang; Jiankun Xu; Ye Chun Ruan; Mei Kuen Yu; Micheal O'Laughlin; Helen Wise; Di Chen; Li Tian; Dufang Shi; Jiali Wang; Sihui Chen; Jian Q Feng; Dick Ho Kiu Chow; Xinhui Xie; Lizhen Zheng; Le Huang; Shuo Huang; Kwoksui Leung; Na Lu; Lan Zhao; Huafang Li; Dewei Zhao; Xia Guo; Kaiming Chan; Frank Witte; Hsiao Chang Chan; Yufeng Zheng; Ling Qin
Journal:  Nat Med       Date:  2016-08-29       Impact factor: 53.440

8.  Bio-Adaption between Magnesium Alloy Stent and the Blood Vessel: A Review.

Authors:  Jun Ma; Nan Zhao; Lexxus Betts; Donghui Zhu
Journal:  J Mater Sci Technol       Date:  2015-12-24       Impact factor: 8.067

9.  Novel zinc alloys for biodegradable surgical staples.

Authors:  Hizuru Amano; Koichi Miyake; Akinari Hinoki; Kazuki Yokota; Fumie Kinoshita; Atsuko Nakazawa; Yujiro Tanaka; Yasuhiro Seto; Hiroo Uchida
Journal:  World J Clin Cases       Date:  2020-02-06       Impact factor: 1.337

10.  In vivo study of self-assembled alkylsilane coated degradable magnesium devices.

Authors:  Avinash Patil; Samer H Zaky; Rong Chong; Kostas Verdelis; Elia Beniash
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2018-04-11       Impact factor: 3.368

View more