Literature DB >> 1606937

Standardised imaging technique for guided M-mode and Doppler echocardiography in the horse.

K J Long1, J D Bonagura, P G Darke.   

Abstract

Eighteen echocardiographic images useful for diagnostic imaging, M-mode echocardiography, and Doppler echocardiography of the equine heart were standardised by relating the position of the axial beam to various intracardiac landmarks. The transducer orientation required for each image was recorded in 14 adult horses by describing the degree of sector rotation and the orientation of the axial beam relative to the thorax. Repeatable images could be obtained within narrow limits of angulation and rotation for 14 of the 18 standardised images evaluated. Twenty-seven National Hunt horses were subsequently examined using this standardised technique. Selected cardiac dimensions were measured from two-dimensional and guided M-mode studies. Satisfactory results were achieved in 26 of the 27 horses. There was no linear correlation between any of the measured cardiac values and bodyweight. There was no significant difference between measurements taken from the left and the right hemithorax. Six horses were imaged on three consecutive days to assess the repeatability of the measurements. No significant difference was found between measurements obtained on different days. This study demonstrates a method for standardised echocardiographic evaluation of the equine heart that is repeatable, valuable for teaching techniques of equine echocardiography, applicable for diagnostic imaging and quantification of cardiac size, and useful for the evaluation of blood-flow patterns by Doppler ultrasound.

Entities:  

Mesh:

Year:  1992        PMID: 1606937     DOI: 10.1111/j.2042-3306.1992.tb02820.x

Source DB:  PubMed          Journal:  Equine Vet J        ISSN: 0425-1644            Impact factor:   2.888


  9 in total

1.  Reliability of quantitative echocardiography in adult sheep and goats.

Authors:  Gayle D Hallowell; Timothy J Potter; I Mark Bowen
Journal:  BMC Vet Res       Date:  2012-09-27       Impact factor: 2.741

2.  Cardiovascular effects of dobutamine and phenylephrine infusion in sevoflurane-anesthetized Thoroughbred horses.

Authors:  Minoru Ohta; Shinjiro Kurimoto; Yuhiro Ishikawa; Hirotaka Tokushige; Naomi Mae; Shun-ichi Nagata; Masayuki Mamada
Journal:  J Vet Med Sci       Date:  2013-07-05       Impact factor: 1.267

3.  Transthoracic M-mode echocardiographic assessment of pulmonary vein-to-pulmonary artery ratio in healthy horses.

Authors:  Domenico Caivano; Andrea Corda; Mark Rishniw; Maria Elena Giorgi; Maria Luisa Pinna Parpaglia; Maria Beatrice Conti; Francesco Porciello; Francesco Birettoni
Journal:  PLoS One       Date:  2019-08-14       Impact factor: 3.240

4.  Three-dimensional and catheter-based intracardiac echocardiographic characterization of the interatrial septum in 2 horses with suspicion of a patent foramen ovale.

Authors:  Ingrid Vernemmen; Ellen Paulussen; Julie Dauvillier; Annelies Decloedt; Gunther van Loon
Journal:  J Vet Intern Med       Date:  2022-05-30       Impact factor: 3.175

5.  Reference Values and Repeatability of Pulsed Wave Doppler Echocardiography Parameters in Normal Donkeys.

Authors:  Mohamed Marzok; Adel I Almubarak; Zakriya Al Mohamad; Mohamed Salem; Alshimaa M Farag; Hussam M Ibrahim; Maged R El-Ashker; Sabry El-Khodery
Journal:  Animals (Basel)       Date:  2022-09-05       Impact factor: 3.231

6.  Repeatability, variability and reference values of pulsed wave Doppler echocardiographic measurements in healthy Saanen goats.

Authors:  Aurélia A Leroux; Frédéric Farnir; Marie L Moonen; Charlotte F Sandersen; Stefan Deleuze; Hélène Amory
Journal:  BMC Vet Res       Date:  2012-10-16       Impact factor: 2.741

7.  Reliability and identification of aortic valve prolapse in the horse.

Authors:  Gayle D Hallowell; Mark Bowen
Journal:  BMC Vet Res       Date:  2013-01-11       Impact factor: 2.741

8.  Pharmacokinetic and pharmacodynamic properties of orally administered torsemide in healthy horses.

Authors:  Gustavo F Agne; Seung Woo Jung; Anne A Wooldridge; Susan H Duran; William Ravis; Ramiro Toribio
Journal:  J Vet Intern Med       Date:  2018-05-17       Impact factor: 3.333

9.  Reference values for 2-dimensional and M-mode echocardiography in Friesian and Warmblood horses.

Authors:  Ingrid Vernemmen; Lisse Vera; Glenn Van Steenkiste; Gunther van Loon; Annelies Decloedt
Journal:  J Vet Intern Med       Date:  2020-10-24       Impact factor: 3.333

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.