Literature DB >> 23065690

Effect of PVP on the electroosmotic mobility of wet-etched glass microchannels.

Denitsa Milanova1, Robert D Chambers, Supreet S Bahga, Juan G Santiago.   

Abstract

We present an experimental study on the effect of polymer PVP on EOF mobility of microchannels wet etched into optical white soda lime glass, also known as Crown glass. We performed experiments to evaluate the effect of PVP concentration and pH on EOF mobility. We used on-chip capillary zone electrophoresis and a neutral fluorescent dye as a passive marker to quantify the electroosmotic flow. We performed experiments under controlled conditions by varying pH from 5.2 and 10.3 and concentration of PVP from 0 to 2.0% w/w at constant ionic strength (30 mM). Our experiments show that PVP at concentrations of 1.0% or above very effectively suppress EOF at low pH (6.6). At high pH of 10.3, PVP has a much weaker suppressing effect on EOF and increasing its concentration above about 0.5% showed negligible effect on EOF mobility. Finally, we briefly discuss the effects of pH on using PVP as an adsorbed coating. Our experiments provide useful guidelines on choosing correct pH and concentration of PVP for effective EOF suppression in glass channels.
© 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23065690     DOI: 10.1002/elps.201200336

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  4 in total

1.  Surface charge, electroosmotic flow and DNA extension in chemically modified thermoplastic nanoslits and nanochannels.

Authors:  Franklin I Uba; Swathi R Pullagurla; Nichanun Sirasunthorn; Jiahao Wu; Sunggook Park; Rattikan Chantiwas; Yoon-Kyoung Cho; Heungjoo Shin; Steven A Soper
Journal:  Analyst       Date:  2015-01-07       Impact factor: 4.616

2.  Refinement of current monitoring methodology for electroosmotic flow assessment under low ionic strength conditions.

Authors:  Mario A Saucedo-Espinosa; Blanca H Lapizco-Encinas
Journal:  Biomicrofluidics       Date:  2016-06-03       Impact factor: 2.800

3.  Transverse migration and microfluidic concentration of DNA using Newtonian buffers.

Authors:  Ryan J Montes; Anthony J C Ladd; Jason E Butler
Journal:  Biomicrofluidics       Date:  2019-07-23       Impact factor: 2.800

4.  Isolation of target DNA using synergistic magnetic bead transport and electrokinetic flow.

Authors:  Lindsay Schneider; Francis Cui; Anubhav Tripathi
Journal:  Biomicrofluidics       Date:  2021-03-17       Impact factor: 2.800

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.