Literature DB >> 11944013

Anatomic and hemodynamic imaging using a new vector phased-array intracardiac catheter.

Peng Li1, Ismail T Dairywala, Zheng Liu, Scott R Stewart, Biju Mathew, Dana Bowie, Mani A Vannan.   

Abstract

BACKGROUND: We used a new vector, phased-array intracardiac catheter (AcuNav) with complete 2-dimensional imaging and Doppler capabilities to describe a systematic approach for a detailed anatomic and hemodynamic cardiac assessment.
METHODS: In 14 dogs, the intracardiac echocardiographic catheter was inserted through an 11F venous access and placed in the right side of the heart to perform a comprehensive ultrasound examination of the heart.
RESULTS: Imaging was successful in all dogs. All 4 cardiac chambers and valves were imaged clearly in multiple orientations. Additional structures seen included the vena cavae, coronary sinus, right and left appendages, interarterial septum, coronary arteries, and all 4 pulmonary veins. Intra-abdominal structures, such as the aorta, liver, and hepatic veins were also visualized. A complete Doppler examination of intracardiac and paracardiac flows was also possible.
CONCLUSION: AcuNav is a unique intracardiac imaging device, which allows comprehensive structural and functional cardiac assessment.

Entities:  

Mesh:

Year:  2002        PMID: 11944013     DOI: 10.1067/mje.2002.116312

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  3 in total

1.  Challenges and implementation of radiation-force imaging with an intracardiac ultrasound transducer.

Authors:  Stephen J Hsu; Brian J Fahey; Douglas M Dumont; Patrick D Wolf; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-05       Impact factor: 2.725

2.  Beat to beat 3-dimensional intracardiac echocardiography: theoretical approach and practical experiences.

Authors:  Daniel Stapf; Andreas Franke; Marcus Schreckenberg; Georg Schummers; Karl Mischke; Nikolaus Marx; Patrick Schauerte; Christian Knackstedt
Journal:  Int J Cardiovasc Imaging       Date:  2012-10-14       Impact factor: 2.357

3.  Cardiac impairment evaluated by transesophageal echocardiography and invasive measurements in rats undergoing sinoaortic denervation.

Authors:  Raquel A Sirvente; Maria C Irigoyen; Leandro E Souza; Cristiano Mostarda; Raquel N La Fuente; Georgia O Candido; Pamella R M Souza; Alessandra Medeiros; Charles Mady; Vera M C Salemi
Journal:  PLoS One       Date:  2014-05-14       Impact factor: 3.240

  3 in total