Anarta Ghosh1, Stefan Ameling, Jiang Zhou, Gerard Lacey, Eilish Creamer, Anthony Dolan, Orla Sherlock, Hilary Humphreys.
Abstract
A novel artificial intelligence (AI) system (SureWash; GLANTA, Dublin, Ireland) was placed on a ward with 45 staff members for two 6-day periods to automatically assess hand hygiene technique and the potential effectiveness of the automated training system. Two human reviewers assessed videos from 50 hand hygiene events with an interrater reliability (IIR) of 88% (44/50). The IIR was 88% (44/50) for the human reviewers and 80% (40/50) for the software. This study also investigated the poses missed and the impact of feedback on participation (+113%), duration (+11%), and technique (+2.23%). Our findings showed significant correlation between the human raters and the computer, demonstrating for the first time in a clinical setting the potential use of this type of AI technology in hand hygiene training.Entities:
Mesh:
Year: 2012 PMID: 23062661 DOI: 10.1016/j.ajic.2012.03.034
Source DB: PubMed Journal: Am J Infect Control ISSN: 0196-6553 Impact factor: 2.918