Literature DB >> 23060144

Reproducibility of subfoveal choroidal thickness measurements with enhanced depth imaging by spectral-domain optical coherence tomography.

Lei Shao1, Liang Xu, Chang Xi Chen, Li Hong Yang, Kui Fang Du, Shuang Wang, Jin Qiong Zhou, Ya Xing Wang, Qi Sheng You, Jost B Jonas, Wen Bin Wei.   

Abstract

PURPOSE: To measure the interobserver reproducibility and intra-observer reproducibility of subfoveal choroidal thickness measurements performed by enhanced depth imaging of spectral-domain optical coherence tomography (EDI-OCT) in a population-based setting.
METHODS: The Beijing Eye Study 2011 was a population-based study performed in rural and urban regions of Greater Beijing. The study included 3468 individuals with a mean age of 64.6 ± 9.8 years (range, 50-93 years). The participants underwent EDI-OCT and the subfoveal choroidal thickness (SFCT) was measured. To examine the interobserver variability, all images were assessed by two examiners independently of each other within 2 months. To examine the intra-observer reproducibility, a smaller study sample consisting of 21 eyes of 21 healthy subjects from the Tongren Eye Center was included in the study. These latter subjects were scanned 10 times with 1 minute breaks between each examination. The SFCT was measured by the same observer within 2 weeks. The intrasession within subject SD, the coefficient of variation, and the intraclass correlation coefficient (ICC) were calculated.
RESULTS: EDI-OCTs were performed for 3233 subjects. Mean SFCT measured by grader one and grader two were 254.6 ± 107.3 μm and 253.8 ± 107.4 μm, respectively, with a mean difference of 3.14 ± 13.1 μm (95% confidence interval, 0.0, 24.0). Bland-Altman plot showed 1.9% (61/3233) points outside the 95% limits of agreement. For the assessment of the intra-observer reproducibility, the ICC was 1.00 (P < 0.001, and the mean coefficient of variation was 0.85% ± 1.48%).
CONCLUSIONS: Under routine examination conditions, SFCT measurements by EDI-OCT showed a high intra-observer reproducibility and interobserver reproducibility.

Entities:  

Mesh:

Year:  2013        PMID: 23060144     DOI: 10.1167/iovs.12-10351

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  33 in total

Review 1.  Enhanced depth imaging-OCT of the choroid: a review of the current literature.

Authors:  H Laviers; H Zambarakji
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-11-04       Impact factor: 3.117

Review 2.  Choroidal thickness changes in obstructive sleep apnea syndrome: a systematic review and meta-analysis.

Authors:  Miao He; Xiao Han; Huiming Wu; Wenyong Huang
Journal:  Sleep Breath       Date:  2016-01-15       Impact factor: 2.816

3.  Retinal dystrophy and subretinal drusenoid deposits in female choroideremia carriers.

Authors:  Vittoria Murro; Dario Pasquale Mucciolo; Ilaria Passerini; Simona Palchetti; Andrea Sodi; Gianni Virgili; Stanislao Rizzo
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-07-27       Impact factor: 3.117

4.  Macular morphology in former preterm and full-term infants aged 4 to 10 years.

Authors:  Achim Fieß; Johannes Janz; Alexander K Schuster; Ruth Kölb-Keerl; Markus Knuf; Bernd Kirchhof; Philipp S Muether; Jacqueline Bauer
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-04-25       Impact factor: 3.117

5.  Influence of choroidal thickness on subfoveal choroidal thickness measurement repeatability using enhanced depth imaging optical coherence tomography.

Authors:  A R Cho; Y J Choi; Y T Kim
Journal:  Eye (Lond)       Date:  2014-09-12       Impact factor: 3.775

6.  Choroidal imaging: A review.

Authors:  Jay Chhablani; Ian Y Wong; Igor Kozak
Journal:  Saudi J Ophthalmol       Date:  2014-03-20

7.  Choroidal thickness in pregnant women: a cross-sectional study.

Authors:  Ru Liu; Guo-Ping Kuang; Di-Xian Luo; Xiao-He Lu
Journal:  Int J Ophthalmol       Date:  2016-08-18       Impact factor: 1.779

8.  An automated method for choroidal thickness measurement from Enhanced Depth Imaging Optical Coherence Tomography images.

Authors:  Md Akter Hussain; Alauddin Bhuiyan; Hiroshi Ishikawa; R Theodore Smith; Joel S Schuman; Ramamohanrao Kotagiri
Journal:  Comput Med Imaging Graph       Date:  2018-01-06       Impact factor: 4.790

9.  Sensitivity and specificity of choroidal thickness measurement by EDI-OCT for central serous chorioretinopathy diagnosis.

Authors:  Javier Orduña-Azcona; Elia Pérez-Fernández; Ana M Guadilla; Sofía De Manuel-Triantafilo; Laura Modamio; Pablo Gili
Journal:  Int Ophthalmol       Date:  2020-09-04       Impact factor: 2.031

10.  Multimodal imaging of the retina and choroid in healthy Macaca fascicularis at different ages.

Authors:  Shuxin Fan; Xiaoyan Ding; Pinhong Rao; Yingfeng Zheng; Fuxiang Mao; Youjin Hu; Xialin Liu; Guoping Fan
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-01-25       Impact factor: 3.117

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.