Literature DB >> 23054907

Detecting aortic valve bicuspidy in patients with severe aortic valve stenosis: high diagnostic accuracy of colour Doppler transoesophageal echocardiography.

Rachid Zegdi1, Vlad Ciobotaru, Clémence Huerre, Bachir Allam, Nadia Bouabdallaoui, Alain Berrebi, Emmanuelle Florens, Jean-Noël Fabiani.   

Abstract

OBJECTIVES: The diagnostic accuracy of multiplane bi-dimensional transoesophageal echocardiography (TEE) in detecting aortic valve bicuspidy is good, but is less reliable when the leaflets are moderately or severely calcified. We hypothesized that systolic colour Doppler analysis might improve the accuracy of diagnosing aortic bicuspidy by TEE in patients with severe symptomatic aortic stenosis (AS).
METHODS: Two colour Doppler images of a stenotic aortic valve were defined in a preliminary study using multiplane TEE. In type I, the valve opening had a linear, angular or 'hanger-like' configuration and in type II it was more star-like or 'stellar'. The accuracy of this classification in detecting bicuspidy was evaluated. Fifty-one patients (mean age 71 years (range 40-90 years); 52% male) with severe symptomatic AS (defined as aortic valve area ≤1 cm(2)), requiring surgical aortic valve replacement, were included in this prospective study. The surgical findings were compared with the echocardiographic data.
RESULTS: The incidence of aortic bicuspidy was 43%. The presence of type I colour Doppler configuration was significantly higher for bicuspid than for tricuspid aortic valves (95.5 vs 3.5%, respectively; P < 0.001). Diagnostic accuracy in detecting bicuspidy was high (sensitivity 95.5%; specificity 96.5%; positive predictive value 95.5%). Intra- and inter-observer agreements were excellent (Kappa coefficient = 0.88 and 0.92, respectively).
CONCLUSIONS: Aortic valve bicuspidy may be accurately diagnosed by colour Doppler valve analysis during TEE in patients with severe AS. Larger prospective studies are required to confirm our results.

Entities:  

Mesh:

Year:  2012        PMID: 23054907      PMCID: PMC3523622          DOI: 10.1093/icvts/ivs382

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  9 in total

1.  Sensitivity and specificity of transesophageal echocardiography for determination of aortic valve morphology.

Authors:  M Espinal; A R Fuisz; N C Nanda; S R Aaluri; O Mukhtar; P C Sekar
Journal:  Am Heart J       Date:  2000-06       Impact factor: 4.749

2.  Clinical and pathophysiological implications of a bicuspid aortic valve.

Authors:  Paul W M Fedak; Subodh Verma; Tirone E David; Richard L Leask; Richard D Weisel; Jagdish Butany
Journal:  Circulation       Date:  2002-08-20       Impact factor: 29.690

3.  ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (writing Committee to Revise the 1998 guidelines for the management of patients with valvular heart disease) developed in collaboration with the Society of Cardiovascular Anesthesiologists endorsed by the Society for Cardiovascular Angiography and Interventions and the Society of Thoracic Surgeons.

Authors:  Robert O Bonow; Blase A Carabello; Kanu Chatterjee; Antonio C de Leon; David P Faxon; Michael D Freed; William H Gaasch; Bruce Whitney Lytle; Rick A Nishimura; Patrick T O'Gara; Robert A O'Rourke; Catherine M Otto; Pravin M Shah; Jack S Shanewise; Sidney C Smith; Alice K Jacobs; Cynthia D Adams; Jeffrey L Anderson; Elliott M Antman; Valentin Fuster; Jonathan L Halperin; Loren F Hiratzka; Sharon A Hunt; Bruce W Lytle; Rick Nishimura; Richard L Page; Barbara Riegel
Journal:  J Am Coll Cardiol       Date:  2006-08-01       Impact factor: 24.094

4.  Calcific bicuspid aortic stenosis: a questionable indication for endovascular valve implantation?

Authors:  Rachid Zegdi; Ziad Khabbaz; Vlad Ciobotaru; Milena Noghin; Alain Deloche; Jean-Noël Fabiani
Journal:  Ann Thorac Surg       Date:  2008-01       Impact factor: 4.330

5.  Frequency by decades of unicuspid, bicuspid, and tricuspid aortic valves in adults having isolated aortic valve replacement for aortic stenosis, with or without associated aortic regurgitation.

Authors:  William C Roberts; Jong M Ko
Journal:  Circulation       Date:  2005-02-14       Impact factor: 29.690

6.  Transcatheter valve implantation for patients with aortic stenosis: a position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI).

Authors:  Alec Vahanian; Ottavio Alfieri; Nawwar Al-Attar; Manuel Antunes; Jeroen Bax; Bertrand Cormier; Alain Cribier; Peter De Jaegere; Gerard Fournial; Arie Pieter Kappetein; Jan Kovac; Susanne Ludgate; Francesco Maisano; Neil Moat; Friedrich Mohr; Patrick Nataf; Luc Piérard; José Luis Pomar; Joachim Schofer; Pilar Tornos; Murat Tuzcu; Ben van Hout; Ludwig K Von Segesser; Thomas Walther
Journal:  Eur Heart J       Date:  2008-05-12       Impact factor: 29.983

7.  Diagnostic value of cardiac CT in the evaluation of bicuspid aortic stenosis: comparison with echocardiography and operative findings.

Authors:  Ryoichi Tanaka; Kunihiro Yoshioka; Hiroyuki Niinuma; Satoshi Ohsawa; Hitoshi Okabayashi; Shigeru Ehara
Journal:  AJR Am J Roentgenol       Date:  2010-10       Impact factor: 3.959

8.  Is it reasonable to treat all calcified stenotic aortic valves with a valved stent? Results from a human anatomic study in adults.

Authors:  Rachid Zegdi; Vlad Ciobotaru; Miléna Noghin; Ghassan Sleilaty; Antoine Lafont; Christian Latrémouille; Alain Deloche; Jean-Noël Fabiani
Journal:  J Am Coll Cardiol       Date:  2008-02-05       Impact factor: 24.094

9.  Impact of valvular calcification on the diagnostic accuracy of transesophageal echocardiography for the detection of congenital aortic valve malformation.

Authors:  Akash Makkar; Tariq S Siddiqui; Marcus F Stoddard; Robert K Lewis; Buddhadeb Dawn
Journal:  Echocardiography       Date:  2007-08       Impact factor: 1.724

  9 in total
  2 in total

1.  Circulating soluble receptor for advanced glycation end product identifies patients with bicuspid aortic valve and associated aortopathies.

Authors:  Emanuela Branchetti; Joseph E Bavaria; Juan B Grau; Richard E Shaw; Paolo Poggio; Eric K Lai; Nimesh D Desai; Joseph H Gorman; Robert C Gorman; Giovanni Ferrari
Journal:  Arterioscler Thromb Vasc Biol       Date:  2014-08-14       Impact factor: 8.311

2.  Diagnostic accuracy study of routine echocardiography for bicuspid aortic valve: a retrospective study and meta-analysis.

Authors:  Mathias Hillebrand; Dietmar Koschyk; Pia Ter Hark; Helke Schüler; Meike Rybczynski; Jürgen Berger; Amit Gulati; Alexander M Bernhardt; Christian Detter; Evaldas Girdauskas; Stefan Blankenberg; Yskert von Kodolitsch
Journal:  Cardiovasc Diagn Ther       Date:  2017-08
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.