OBJECTIVES: The diagnostic accuracy of multiplane bi-dimensional transoesophageal echocardiography (TEE) in detecting aortic valve bicuspidy is good, but is less reliable when the leaflets are moderately or severely calcified. We hypothesized that systolic colour Doppler analysis might improve the accuracy of diagnosing aortic bicuspidy by TEE in patients with severe symptomatic aortic stenosis (AS). METHODS: Two colour Doppler images of a stenotic aortic valve were defined in a preliminary study using multiplane TEE. In type I, the valve opening had a linear, angular or 'hanger-like' configuration and in type II it was more star-like or 'stellar'. The accuracy of this classification in detecting bicuspidy was evaluated. Fifty-one patients (mean age 71 years (range 40-90 years); 52% male) with severe symptomatic AS (defined as aortic valve area ≤1 cm(2)), requiring surgical aortic valve replacement, were included in this prospective study. The surgical findings were compared with the echocardiographic data. RESULTS: The incidence of aortic bicuspidy was 43%. The presence of type I colour Doppler configuration was significantly higher for bicuspid than for tricuspid aortic valves (95.5 vs 3.5%, respectively; P < 0.001). Diagnostic accuracy in detecting bicuspidy was high (sensitivity 95.5%; specificity 96.5%; positive predictive value 95.5%). Intra- and inter-observer agreements were excellent (Kappa coefficient = 0.88 and 0.92, respectively). CONCLUSIONS: Aortic valve bicuspidy may be accurately diagnosed by colour Doppler valve analysis during TEE in patients with severe AS. Larger prospective studies are required to confirm our results.
OBJECTIVES: The diagnostic accuracy of multiplane bi-dimensional transoesophageal echocardiography (TEE) in detecting aortic valve bicuspidy is good, but is less reliable when the leaflets are moderately or severely calcified. We hypothesized that systolic colour Doppler analysis might improve the accuracy of diagnosing aortic bicuspidy by TEE in patients with severe symptomatic aortic stenosis (AS). METHODS: Two colour Doppler images of a stenotic aortic valve were defined in a preliminary study using multiplane TEE. In type I, the valve opening had a linear, angular or 'hanger-like' configuration and in type II it was more star-like or 'stellar'. The accuracy of this classification in detecting bicuspidy was evaluated. Fifty-one patients (mean age 71 years (range 40-90 years); 52% male) with severe symptomatic AS (defined as aortic valve area ≤1 cm(2)), requiring surgical aortic valve replacement, were included in this prospective study. The surgical findings were compared with the echocardiographic data. RESULTS: The incidence of aortic bicuspidy was 43%. The presence of type I colour Doppler configuration was significantly higher for bicuspid than for tricuspid aortic valves (95.5 vs 3.5%, respectively; P < 0.001). Diagnostic accuracy in detecting bicuspidy was high (sensitivity 95.5%; specificity 96.5%; positive predictive value 95.5%). Intra- and inter-observer agreements were excellent (Kappa coefficient = 0.88 and 0.92, respectively). CONCLUSIONS: Aortic valve bicuspidy may be accurately diagnosed by colour Doppler valve analysis during TEE in patients with severe AS. Larger prospective studies are required to confirm our results.
Authors: Paul W M Fedak; Subodh Verma; Tirone E David; Richard L Leask; Richard D Weisel; Jagdish Butany Journal: Circulation Date: 2002-08-20 Impact factor: 29.690
Authors: Robert O Bonow; Blase A Carabello; Kanu Chatterjee; Antonio C de Leon; David P Faxon; Michael D Freed; William H Gaasch; Bruce Whitney Lytle; Rick A Nishimura; Patrick T O'Gara; Robert A O'Rourke; Catherine M Otto; Pravin M Shah; Jack S Shanewise; Sidney C Smith; Alice K Jacobs; Cynthia D Adams; Jeffrey L Anderson; Elliott M Antman; Valentin Fuster; Jonathan L Halperin; Loren F Hiratzka; Sharon A Hunt; Bruce W Lytle; Rick Nishimura; Richard L Page; Barbara Riegel Journal: J Am Coll Cardiol Date: 2006-08-01 Impact factor: 24.094
Authors: Alec Vahanian; Ottavio Alfieri; Nawwar Al-Attar; Manuel Antunes; Jeroen Bax; Bertrand Cormier; Alain Cribier; Peter De Jaegere; Gerard Fournial; Arie Pieter Kappetein; Jan Kovac; Susanne Ludgate; Francesco Maisano; Neil Moat; Friedrich Mohr; Patrick Nataf; Luc Piérard; José Luis Pomar; Joachim Schofer; Pilar Tornos; Murat Tuzcu; Ben van Hout; Ludwig K Von Segesser; Thomas Walther Journal: Eur Heart J Date: 2008-05-12 Impact factor: 29.983
Authors: Akash Makkar; Tariq S Siddiqui; Marcus F Stoddard; Robert K Lewis; Buddhadeb Dawn Journal: Echocardiography Date: 2007-08 Impact factor: 1.724
Authors: Emanuela Branchetti; Joseph E Bavaria; Juan B Grau; Richard E Shaw; Paolo Poggio; Eric K Lai; Nimesh D Desai; Joseph H Gorman; Robert C Gorman; Giovanni Ferrari Journal: Arterioscler Thromb Vasc Biol Date: 2014-08-14 Impact factor: 8.311
Authors: Mathias Hillebrand; Dietmar Koschyk; Pia Ter Hark; Helke Schüler; Meike Rybczynski; Jürgen Berger; Amit Gulati; Alexander M Bernhardt; Christian Detter; Evaldas Girdauskas; Stefan Blankenberg; Yskert von Kodolitsch Journal: Cardiovasc Diagn Ther Date: 2017-08