Literature DB >> 17651104

Impact of valvular calcification on the diagnostic accuracy of transesophageal echocardiography for the detection of congenital aortic valve malformation.

Akash Makkar1, Tariq S Siddiqui, Marcus F Stoddard, Robert K Lewis, Buddhadeb Dawn.   

Abstract

BACKGROUND: Degeneration of congenital bicuspid or unicuspid aortic valves can progress more rapidly than that of tricuspid valves, and an early diagnosis significantly impacts decision making and outcome. We hypothesized that the extent of valvular calcification would negatively influence the diagnostic accuracy of multiplane transesophageal echocardiography (TEE) for the diagnosis of congenital aortic valve disease.
METHODS: TEE was performed in 57 patients undergoing aortic valve replacement surgery for aortic stenosis (n = 46), pure regurgitation (n = 9), or significant regurgitation with less than severe aortic stenosis (n = 2). The degree of aortic valve calcification and the number of valve cusps were determined at surgery.
RESULTS: Surgical inspection confirmed 14 bicuspid and 43 tricuspid aortic valves. Sensitivity and specificity of TEE for the diagnosis of congenital aortic valve malformation was 93% (13/14) and 91% (39/43) (P = 0.0001), respectively. In patients with no or mild aortic valve calcification (n = 13), sensitivity and specificity of TEE for the diagnosis of congenitally malformed aortic valve was 100% (5/5) and 100% (8/8) (P = 0.001), respectively. In patients with moderate or marked aortic valve calcification (n = 44), sensitivity and specificity of TEE for the diagnosis of congenitally malformed aortic valve was 89% (8/9) and 89% (31/35) (P<0.0001), respectively. In this subgroup of 44 patients, there were four false-positive and one false-negative diagnoses due to valvular calcification.
CONCLUSIONS: Although TEE is highly sensitive and specific for the detection of congenital aortic valve malformations, presence of moderate or marked calcification of the aortic valve may result in false positive and false negative diagnoses.

Entities:  

Mesh:

Year:  2007        PMID: 17651104     DOI: 10.1111/j.1540-8175.2007.00459.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  4 in total

1.  Impact and predictors of noncircular left ventricular outflow tract shapes on estimating aortic stenosis severity by means of continuity equations.

Authors:  Nirmanmoh Bhatia; Buddhadeb Dawn; Tariq S Siddiqui; Marcus F Stoddard
Journal:  Tex Heart Inst J       Date:  2015-02-01

2.  Detecting aortic valve bicuspidy in patients with severe aortic valve stenosis: high diagnostic accuracy of colour Doppler transoesophageal echocardiography.

Authors:  Rachid Zegdi; Vlad Ciobotaru; Clémence Huerre; Bachir Allam; Nadia Bouabdallaoui; Alain Berrebi; Emmanuelle Florens; Jean-Noël Fabiani
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-10-10

3.  MDCT differentiation between bicuspid and tricuspid aortic valves in patients with aortic valvular disease: correlation with surgical findings.

Authors:  Ijin Joo; Eun-Ah Park; Kyung-Hwan Kim; Whal Lee; Jin Wook Chung; Jae Hyung Park
Journal:  Int J Cardiovasc Imaging       Date:  2011-01-08       Impact factor: 2.357

4.  Diagnostic accuracy study of routine echocardiography for bicuspid aortic valve: a retrospective study and meta-analysis.

Authors:  Mathias Hillebrand; Dietmar Koschyk; Pia Ter Hark; Helke Schüler; Meike Rybczynski; Jürgen Berger; Amit Gulati; Alexander M Bernhardt; Christian Detter; Evaldas Girdauskas; Stefan Blankenberg; Yskert von Kodolitsch
Journal:  Cardiovasc Diagn Ther       Date:  2017-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.