Literature DB >> 23053341

[Evaluation of the valence objective and subjective methods for measuring pseudophakic accommodation].

D Uthoff1, W Haigis, D Hepper, M Pölzl, D Holland.   

Abstract

PURPOSE: The aim of this study was to compare the validity and plausibility of various subjective and objective measurement methods for evaluation of pseudophakic accommodation.
SETTING: Eye Clinic Bellevue, Kiel, Germany.
METHODS: A total of 21 patients were examined over an average period of 34 months (range 12-51 months) after implantation of a potentially accommodative, model 1CU intraocular lens (IOL, HumanOptics, Germany). The following subjective measurements were taken: near point measurement with the accommodometer (Clement Clarke, Harlow, UK), defocus curve and near visual acuity with far and near reading charts. The IOLMaster (Carl Zeiss Meditec, Germany), ACMaster (Carl Zeiss Meditec, Germany) and Shin-Nippon K 5001 AR (Shin-Nippon, Japan) were employed as objective measurement devices. With this devices information is obtained about the anterior chamber depth (ACD, preoperative and postoperative), the movement of the IOL and the refractive change of eyes during the accommodative process.
RESULTS: Depending on the method utilized there were large variations of the examined IOL in relation to the extent of the measured accommodative effects in their entirety with the objective as well as the subjective measurement method.
CONCLUSIONS: A differentiation of pseudophakic accommodation and pseudophakic pseudoaccommodation is not possible with the conventional measurement methods applied and examined in this study. Only the ACMaster is an objective method for measurement of the axial shift of an IOL. However, subjective measurement methods can only record the total of both accommodation portions but do not allow any scientifically-founded statement about the functional principle of a potentially accommodative IOL.

Entities:  

Mesh:

Year:  2013        PMID: 23053341     DOI: 10.1007/s00347-012-2695-8

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  16 in total

1.  Measurement of accommodation after implantation of an accommodating posterior chamber intraocular lens.

Authors:  Achim Langenbucher; Stefan Huber; Nhung X Nguyen; Berthold Seitz; Gabriele C Gusek-Schneider; Michael Küchle
Journal:  J Cataract Refract Surg       Date:  2003-04       Impact factor: 3.351

2.  Theoretical and measured pseudophakic accommodation after implantation of a new accommodative posterior chamber intraocular lens.

Authors:  Achim Langenbucher; Berthold Seitz; Stefan Huber; Nhung X Nguyen; Michael Kuchle
Journal:  Arch Ophthalmol       Date:  2003-12

3.  Stability of refraction, accommodation, and lens position after implantation of the 1CU accommodating posterior chamber intraocular lens.

Authors:  Michael Küchle; Berthold Seitz; Achim Langenbucher; Peter Martus; Nhung X Nguyen
Journal:  J Cataract Refract Surg       Date:  2003-12       Impact factor: 3.351

4.  Objective accommodative amplitude and dynamics with the 1CU accommodative intraocular lens.

Authors:  James Stuart Wolffsohn; Olivia Anne Hunt; Shehzad Naroo; Bernard Gilmartin; Sunil Shah; Ian Andrew Cunliffe; Mark Timothy Benson; Sanjay Mantry
Journal:  Invest Ophthalmol Vis Sci       Date:  2006-03       Impact factor: 4.799

5.  Laserinterferometric measurements of accommodative changes in the position of an optic-shift intraocular lens.

Authors:  Detlef Uthoff; Detlef Holland; Daniel Hepper; Amit Gulati; Lioba Koch; Wolfgang Haigis
Journal:  J Refract Surg       Date:  2009-05       Impact factor: 3.573

Review 6.  Comparison of phacoemulsification and planned extracapsular extraction.

Authors:  C Ohrloff; A A Zubcov
Journal:  Ophthalmologica       Date:  1997       Impact factor: 3.250

7.  Clinical evaluation of the model AT-45 silicone accommodating intraocular lens: results of feasibility and the initial phase of a Food and Drug Administration clinical trial.

Authors:  J S Cumming; S G Slade; A Chayet
Journal:  Ophthalmology       Date:  2001-11       Impact factor: 12.079

8.  Different techniques of extracapsular cataract extraction: bacterial contamination during surgery. Prospective study on 230 consecutive patients.

Authors:  S F Egger; V Huber-Spitzy; C Skorpik; H Weghaupt; C Scholda; E Arocker-Mettinger; B Schneider; G Grabner
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1994-05       Impact factor: 3.117

9.  Clinical study of the 1CU accommodating intraocular lens.

Authors:  Leonardo Mastropasqua; Lisa Toto; Mario Nubile; Gennaro Falconio; Enzo Ballone
Journal:  J Cataract Refract Surg       Date:  2003-07       Impact factor: 3.351

Review 10.  Potentially accommodating 1CU intraocular lens: 1-year results in 553 eyes and literature review.

Authors:  Detlef Uthoff; Amit Gulati; Daniel Hepper; Detlef Holland
Journal:  J Refract Surg       Date:  2007-02       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.