Literature DB >> 17326355

Potentially accommodating 1CU intraocular lens: 1-year results in 553 eyes and literature review.

Detlef Uthoff1, Amit Gulati, Daniel Hepper, Detlef Holland.   

Abstract

PURPOSE: To investigate the advantages, clinical outcomes, and safety after implantation of the 1CU (HumanOptics AG) optic shift intraocular lens (IOL) in comparison with a conventional monofocal IOL.
METHODS: In a prospective non-randomized study, 553 eyes implanted with the 1CU IOL were examined. In a control group, a monofocal posterior chamber IOL (MCTE, Dr Schmidt) was implanted in 219 eyes. Follow-up was performed at 1, 6, and 12 months postoperatively. The clinical effect for near visual acuity was evaluated by subjective measurements using an accommodometer, defocusing curve, and Nieden charts.
RESULTS: No significant differences were noted in distance best spectacle-corrected visual acuity (BSCVA) between groups. Average near visual acuity with distance BSCVA for the 1CU was 0.41 and 0.35 for the control group. The difference in the accommodation response between both groups measured with the accommodometer was 11 cm (P < .01). The refraction tolerance for the 1CU was 0.25 D whereas the MCTE revealed no refraction tolerance (P < .01). Decentration and tilting of the 1CU resulted in explantation of three IOLs.
CONCLUSIONS: The 1CU indicates a minor statistical advantage of half a reading step towards monofocal IOLs measured with subjective methods in near point, defocusing curve, and near visual acuity with distance BSCVA. This could be due to pseudophakic accommodation by the optic shift mechanism or a result of additional pseudophakic pseudoaccommodation. The accommodative effect of the 1CU differed from patient to patient and was not predictable.

Entities:  

Mesh:

Year:  2007        PMID: 17326355     DOI: 10.3928/1081-597X-20070201-08

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  6 in total

1.  A new method of cornea modulation with excimer laser for simultaneous correction of presbyopia and ametropia.

Authors:  Detlef Uthoff; Markus Pölzl; Daniel Hepper; Detlef Holland
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-02-22       Impact factor: 3.117

Review 2.  [Accommodation and presbyopia : part 2: surgical procedures for the correction of presbyopia].

Authors:  M Baumeister; T Kohnen
Journal:  Ophthalmologe       Date:  2008-11       Impact factor: 1.059

3.  Aphakic retropupillary iris-claw intraocular lens (IOL) pseudophakic accommodation.

Authors:  Virgilio Galvis; Alejandro Tello; Néstor I Carreño; Mario L Revelo
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-06-04       Impact factor: 3.117

4.  [Evaluation of the valence objective and subjective methods for measuring pseudophakic accommodation].

Authors:  D Uthoff; W Haigis; D Hepper; M Pölzl; D Holland
Journal:  Ophthalmologe       Date:  2013-05       Impact factor: 1.059

5.  Positional accommodative intraocular lens power error induced by the estimation of the corneal power and the effective lens position.

Authors:  David P Piñero; Vicente J Camps; MarIa L Ramón; Verónica Mateo; Rafael J Pérez-CambrodI
Journal:  Indian J Ophthalmol       Date:  2015-05       Impact factor: 1.848

Review 6.  Accommodative intraocular lenses: where are we and where we are going.

Authors:  Jorge L Alió; Jorge L Alió Del Barrio; Alfredo Vega-Estrada
Journal:  Eye Vis (Lond)       Date:  2017-06-26
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.