Literature DB >> 23052521

Energy consumption during simulated minimal access surgery with and without using an armrest.

Mansoor Jafri1, Stuart Brown, Graham Arnold, Rami Abboud, Weijie Wang.   

Abstract

BACKGROUND: Minimal access surgery (MAS) can be a lengthy procedure when compared to open surgery and therefore surgeon fatigue becomes an important issue and surgeons may expose themselves to chronic injuries and making errors. There have been few studies on this topic and they have used only questionnaires and electromyography rather than direct measurement of energy expenditure (EE). The aim of this study was to investigate whether the use of an armrest could reduce the EE of surgeons during MAS.
METHOD: Sixteen surgeons performed simulated MAS with and without using an armrest. They were required to perform the time-consuming task of using scissors to cut a rubber glove through its top layer in a triangular fashion with the help of a laparoscopic camera. Energy consumptions were measured using the Oxycon Mobile system during all the procedures. Error rate and duration time for simulated surgery were recorded. After performing the simulated surgery, subjects scored how comfortable they felt using the armrest.
RESULTS: It was found that O(2) uptake (VO(2)) was 5 % less when surgeons used the armrest. The error rate when performing the procedure with the armrest was 35 % compared with 42.29 % without the armrest. Additionally, comfort levels with the armrest were higher than without the armrest. 75 % of surgeons indicated a preference for using the armrest during the simulated surgery.
CONCLUSION: The armrest provides support for surgeons and cuts energy consumption during simulated MAS.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23052521     DOI: 10.1007/s00464-012-2544-5

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  6 in total

1.  An ergonomic evaluation of surgeons' axial skeletal and upper extremity movements during laparoscopic and open surgery.

Authors:  N T Nguyen; H S Ho; W D Smith; C Philipps; C Lewis; R M De Vera; R Berguer
Journal:  Am J Surg       Date:  2001-12       Impact factor: 2.565

2.  Comparison of two actuation systems for laparoscopic surgical manipulators using motion analysis.

Authors:  Yogesh Vinod Kolwadkar; Stuart I Brown; Rami J Abboud; Weijie Wang
Journal:  Surg Endosc       Date:  2010-08-24       Impact factor: 4.584

3.  Evaluation of a mobile unit for indirect calorimetry during spontaneous ventilation.

Authors:  E Forsberg; M Carlsson; A Thörne; G Hedenstierna; O Björkman
Journal:  Int J Clin Monit Comput       Date:  1986

4.  Assessment of fatigue, monitor placement, and surgical experience during simulated laparoscopic surgery.

Authors:  M L Uhrich; R A Underwood; J W Standeven; N J Soper; J R Engsberg
Journal:  Surg Endosc       Date:  2001-12-17       Impact factor: 4.584

5.  Can armrests improve comfort and task performance in laparoscopic surgery?

Authors:  Raffaele Galleano; Fiona Carter; Stuart Brown; Timothy Frank; Alfred Cuschieri
Journal:  Ann Surg       Date:  2006-03       Impact factor: 12.969

Review 6.  Minimal access surgery (MAS)-related surgeon morbidity syndromes.

Authors:  D A G Reyes; B Tang; A Cuschieri
Journal:  Surg Endosc       Date:  2005-12-06       Impact factor: 3.453

  6 in total
  4 in total

1.  "Alarm-corrected" ergonomic armrest use could improve learning curves of novices on robotic simulator.

Authors:  Kun Yang; Manuela Perez; Gabriela Hossu; Nicolas Hubert; Cyril Perrenot; Jacques Hubert
Journal:  Surg Endosc       Date:  2016-05-17       Impact factor: 4.584

2.  Comparative assessment of surgeons' task performance and surgical ergonomics associated with conventional and modified flank positions: a simulation study.

Authors:  Yu Fan; Gaiqing Kong; Yisen Meng; Shutao Tan; Kunlin Wei; Qian Zhang; Jie Jin
Journal:  Surg Endosc       Date:  2014-06-14       Impact factor: 4.584

3.  Development of an arm support system to improve ergonomics in laparoscopic surgery: study design and provisional results.

Authors:  Benjamin Steinhilber; Sascha Hoffmann; Kristian Karlovic; Stefan Pfeffer; Thomas Maier; Omar Hallasheh; Stephan Kruck; Robert Seibt; Monika A Rieger; Michael Heidingsfeld; Ronny Feuer; Oliver Sawodny; Ralf Rothmund; Karl-Dietrich Sievert
Journal:  Surg Endosc       Date:  2014-12-25       Impact factor: 4.584

4.  Using end-user feedback to optimize the design of the Versius Surgical System, a new robot-assisted device for use in minimal access surgery.

Authors:  Luke Hares; Paul Roberts; Keith Marshall; Mark Slack
Journal:  BMJ Surg Interv Health Technol       Date:  2019-12-02
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.