Literature DB >> 23027205

Three-dimensional lymphoscintigraphy using SPECT/CT and 123I-BMIPP for the preoperative detection of anatomical anomalies of the thoracic duct.

Kentaro Takanami1, Hirofumi Ichikawa, Hiroshi Fukuda, Shoki Takahashi.   

Abstract

PURPOSE: Orally administered I-labeled 15-(4-iodophenyl)-3(R,S)-methylpentadecanoic acid (BMIPP), a fatty acid analog, is absorbed from the intestine and ascends to the venous angle through the thoracic duct (TD). The objective of this study was to evaluate the clinical feasibility of 3-dimensional (3D) TD scintigraphy using SPECT/CT and BMIPP for the detection of anatomical anomalies of TD. PATIENTS AND METHODS: This study included 35 consecutive patients with esophageal cancer who underwent tumor resection after TD scintigraphy. For scintigraphy, 111 MBq of BMIPP was orally administered, and static images and SPECT/CT images were obtained. On the basis of the SPECT/CT fusion images, TD was divided into the following 4 segments: cervical, upper thoracic, middle thoracic, and lower thoracic. The TD visualization was categorized into 5 grades, from grade 1 (poor) to 5 (excellent). In addition, the diagnostic accuracy of 3D TD scintigraphy for the detection of anatomical anomalies of TD was calculated using the intraoperative finding as a criterion standard.
RESULTS: The TD visualization grades for the cervical, upper, middle, and lower thoracic segments were 4.4 ± 0.6, 3.7 ± 1.0, 3.1 ± 0.8, and 2.1 ± 0.9, respectively. The TD scintigraphy demonstrated an uncommon accumulation including that in the right- or bilateral-sided mediastinum or venous angle in 6 (17%) of the 35 patients. Sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of 3D TD scintigraphy for the detection of anatomical anomalies of TD were 0.75, 0.90, 0.5, 0.97, and 0.89, respectively.
CONCLUSIONS: Three-dimensional TD scintigraphy by BMIPP is a simple and minimally invasive method for imaging the anatomical configuration of the TD and for detecting any anatomical anomalies, except in the lower thoracic segment.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23027205     DOI: 10.1097/RLU.0b013e31825b208f

Source DB:  PubMed          Journal:  Clin Nucl Med        ISSN: 0363-9762            Impact factor:   7.794


  4 in total

Review 1.  Utility of three-dimensional computed tomography in general thoracic surgery.

Authors:  Tadashi Akiba
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-10-25

2.  Clinical Significance of New Magnetic Resonance Thoracic Ductography Before Thoracoscopic Esophagectomy for Esophageal Cancer.

Authors:  Junya Oguma; Soji Ozawa; Akihito Kazuno; Miho Nitta; Yamato Ninomiya; Kentaro Yatabe; Tetsu Niwa; Takakiyo Nomura
Journal:  World J Surg       Date:  2018-06       Impact factor: 3.352

Review 3.  The anatomy and physiology of the terminal thoracic duct and ostial valve in health and disease: potential implications for intervention.

Authors:  Chathura Bathiya Bandara Ratnayake; Alistair Brian James Escott; Anthony Ronald John Phillips; John Albert Windsor
Journal:  J Anat       Date:  2018-04-10       Impact factor: 2.610

Review 4.  The current and possible future role of 3D modelling within oesophagogastric surgery: a scoping review.

Authors:  Henry Robb; Gemma Scrimgeour; Piers Boshier; Anna Przedlacka; Svetlana Balyasnikova; Gina Brown; Fernando Bello; Christos Kontovounisios
Journal:  Surg Endosc       Date:  2022-03-11       Impact factor: 3.453

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.