Literature DB >> 23023455

Variability of shear wave velocity using different frequencies in acoustic radiation force impulse (ARFI) elastography: a phantom and normal liver study.

S Chang1, M-J Kim, J Kim, M-J Lee.   

Abstract

PURPOSE: To assess the variability of shear wave velocity (SWV) from acoustic radiation force impulse (ARFI) elastography at various depths using different frequencies.
MATERIALS AND METHODS: ARFI elastography of the elasticity phantom and normal liver was performed at different depths (2-5 cm) with convex (1-4 MHz) and linear (4-9 MHz) probes. Ten valid SWV measurements at each depth were performed. This was repeated ten times with the phantom and performed in eight healthy volunteers (M:F = 3:5, age 20-34 years). The mean value and standard deviation of the SWV were calculated.
RESULTS: In both the phantom and liver, the mean velocities as measured by two probes at the same depth were different. Variabilities of SWV at different depths were also different for the two probes. The depth with lower variability in the phantom was 4 and 5 cm with a convex probe and 2 cm with a linear probe. In the liver, the depth with lower variability was 4 cm with a convex probe and 3 and 4 cm with a linear probe. In comparative analysis of the two probes, the linear probe displayed a lower variability at a depth of 2 and 3 cm in the phantom and at 3 cm in the liver, whereas the convex probe displayed a lower variability at a depth of 4 cm in both the phantom and the liver.
CONCLUSION: SWVs and variability are different depending on the depth and the frequency used. SWVs with a low frequency probe had a tendency to be higher at the same depth. To reduce variability of SWV, a high frequency probe is recommended for a depth of 2-3 cm, and a low frequency probe is recommended for a depth of 4-5 cm. © Georg Thieme Verlag KG Stuttgart · New York.

Mesh:

Year:  2012        PMID: 23023455     DOI: 10.1055/s-0032-1313008

Source DB:  PubMed          Journal:  Ultraschall Med        ISSN: 0172-4614            Impact factor:   6.548


  23 in total

1.  Comparison of shear wave velocities on ultrasound elastography between different machines, transducers, and acquisition depths: a phantom study.

Authors:  Hyun Joo Shin; Myung-Joon Kim; Ha Yan Kim; Yun Ho Roh; Mi-Jung Lee
Journal:  Eur Radiol       Date:  2016-01-26       Impact factor: 5.315

2.  Effect of depth on shear-wave elastography estimated in the internal and external cervical os during pregnancy.

Authors:  Edgar Hernandez-Andrade; Alma Aurioles-Garibay; Maynor Garcia; Steven J Korzeniewski; Alyse G Schwartz; Hyunyoung Ahn; Alicia Martinez-Varea; Lami Yeo; Tinnakorn Chaiworapongsa; Sonia S Hassan; Roberto Romero
Journal:  J Perinat Med       Date:  2014-09       Impact factor: 1.901

3.  Correlation between acoustic radiation force impulse (ARFI)-based tissue elasticity measurements and perfusion parameters acquired by perfusion CT in cirrhotic livers: a proof of principle.

Authors:  Michael Esser; Michael Bitzer; Manuel Kolb; Jan Fritz; Mustafa Kurucay; Christer Ruff; Marius Horger
Journal:  J Med Ultrason (2001)       Date:  2018-06-13       Impact factor: 1.314

4.  Contrast-enhanced ultrasonography for the evaluation of liver fibrosis after biliary obstruction.

Authors:  Hyun Joo Shin; Eun Young Chang; Hye Sun Lee; Jung Hwa Hong; Gyuri Park; Hyun Gi Kim; Myung-Joon Kim; Mi-Jung Lee
Journal:  World J Gastroenterol       Date:  2015-03-07       Impact factor: 5.742

5.  Technical feasibility and correlations between shear-wave elastography and histology in kidney fibrosis in children.

Authors:  Catherine Desvignes; Alexia Dabadie; Audrey Aschero; Alix Ruocco; Florentine Garaix; Laurent Daniel; Sophie Ferlicot; Virginie Villes; Anderson D Loundou; Guillaume Gorincour; Philippe Petit
Journal:  Pediatr Radiol       Date:  2021-04-24

6.  Diagnostic Performance of MR Elastography and Vibration-controlled Transient Elastography in the Detection of Hepatic Fibrosis in Patients with Severe to Morbid Obesity.

Authors:  Jun Chen; Meng Yin; Jayant A Talwalkar; Jennifer Oudry; Kevin J Glaser; Thomas C Smyrk; Véronique Miette; Laurent Sandrin; Richard L Ehman
Journal:  Radiology       Date:  2016-11-18       Impact factor: 11.105

7.  Assessment of ultrasound shear wave elastography within muscles using different region of interest sizes, manufacturers, probes and acquisition angles: an ex vivo study.

Authors:  Xiuming Wang; Jiaan Zhu; Junxue Gao; Yue Hu; Yiqun Liu; Wenxue Li; Si Chen; Feifei Liu
Journal:  Quant Imaging Med Surg       Date:  2022-06

Review 8.  Noninvasive diagnosis of cirrhosis: a review of different imaging modalities.

Authors:  Riccardo De Robertis; Mirko D'Onofrio; Emanuele Demozzi; Stefano Crosara; Stefano Canestrini; Roberto Pozzi Mucelli
Journal:  World J Gastroenterol       Date:  2014-06-21       Impact factor: 5.742

9.  Parameters affecting different acoustic radiation force impulse applications in the diagnosis of fibrotic liver changes.

Authors:  Sabrina Galgenmueller; Heike Jaeger; Wolfgang Kratzer; Stefan A Schmidt; Suemeyra Oeztuerk; Mark M Haenle; Richard A Mason; Tilmann Graeter
Journal:  World J Gastroenterol       Date:  2015-07-21       Impact factor: 5.742

10.  Shear wave elastography in chronic kidney disease: a pilot experience in native kidneys.

Authors:  Anthony E Samir; Andrew S Allegretti; Qingli Zhu; Manish Dhyani; Arash Anvari; Dorothy A Sullivan; Caitlin A Trottier; Sarah Dougherty; Winfred W Williams; Jodie L Babitt; Julia Wenger; Ravi I Thadhani; Herbert Y Lin
Journal:  BMC Nephrol       Date:  2015-07-31       Impact factor: 2.388

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.