Literature DB >> 23023228

Improved agreement between experienced and inexperienced observers using a standardized evaluation protocol for cardiac volumetry and infarct size measurement.

M Groth1, K Muellerleile, T Klink, D Säring, S Halaj, G Folwarski, M Kaul, P Bannas, G Adam, G K Lund.   

Abstract

PURPOSE: To study the agreement between experienced and inexperienced observers before and after training using a standardized evaluation protocol for cardiac magnetic resonance imaging (CMR) measurements of left ventricular (LV) volumes, mass and infarct size.
MATERIALS AND METHODS: First, 10 CMR studies from patients with myocardial infarction were analyzed by 2 experienced and 4 inexperienced observers in respect to end-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF), LV mass and infarct size. Subsequently, the inexperienced observers were trained using a standardized evaluation protocol. Thereafter, all observers analyzed another 10 CMR studies.
RESULTS: Before training the relative difference between experienced and inexperienced observers was -4.3±8.2% for EDV, -13.3±14.2% for ESV, 5.9±8.2% for EF, -12.2±10.9% for LV mass and -27.0±29.0% for infarct size in gram. After training, agreement significantly improved to 0.2±8.8% for EDV (p<0.05), -2.1±10.9 for ESV (p<0.01), 1.5±6.9% for EF (p<0.05), and -3.6±17.1% for infarct size (p<0.0001), but no improvement was seen for LV mass (-11.2±7.9, p=0.64). A slice based analysis showed, that the variable inclusion of the most basal and apical slices were mainly responsible for the low agreement of the measurements before training.
CONCLUSION: Training using a standardized evaluation protocol significantly improved the agreement between experienced and inexperienced observers for important CMR parameters. The proposed evaluation protocol can be used for training to improve the reproducibility of CMR measurements. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2012        PMID: 23023228     DOI: 10.1055/s-0032-1313171

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  6 in total

1.  Precision of pulmonary vein diameter measurements assessed by CE-MRA and steady-state-free precession imaging.

Authors:  Michael Groth; Peter Bannas; Marc Regier; Jan H Buhk; Kai Müllerleile; Gerhard Adam; Frank O Henes
Journal:  Eur Radiol       Date:  2012-12-20       Impact factor: 5.315

2.  Single-Breath-Hold Evaluation of Cardiac Function with Use of Time-Resolved Parallel Cardiac Magnetic Resonance.

Authors:  Patrick Krumm; Jonas D Keuler; Stefanie Mangold; Tanja Zitzelsberger; Christer A Ruff; Bernhard D Klumpp; Petros Martirosian; Konstantin Nikolaou; Christof Burgstahler; Ulrich Kramer
Journal:  Tex Heart Inst J       Date:  2017-08-01

Review 3.  Clinical use of cardiac PET/MRI: current state-of-the-art and potential future applications.

Authors:  Patrick Krumm; Stefanie Mangold; Sergios Gatidis; Konstantin Nikolaou; Felix Nensa; Fabian Bamberg; Christian la Fougère
Journal:  Jpn J Radiol       Date:  2018-03-10       Impact factor: 2.374

4.  Clinical Performance and Role of Expert Supervision of Deep Learning for Cardiac Ventricular Volumetry: A Validation Study.

Authors:  Tara A Retson; Evan M Masutani; Daniel Golden; Albert Hsiao
Journal:  Radiol Artif Intell       Date:  2020-07-08

5.  Cardiovascular magnetic resonance patterns of biopsy proven cardiac involvement in systemic sclerosis.

Authors:  Patrick Krumm; Karin A L Mueller; Karin Klingel; Ulrich Kramer; Marius S Horger; Tanja Zitzelsberger; Reinhard Kandolf; Meinrad Gawaz; Konstantin Nikolaou; Bernhard D Klumpp; Joerg C Henes
Journal:  J Cardiovasc Magn Reson       Date:  2016-10-21       Impact factor: 5.364

6.  The effect of initial teaching on evaluation of left ventricular volumes by cardiovascular magnetic resonance imaging: comparison between complete and intermediate beginners and experienced observers.

Authors:  Erik Hedström; Masaki Ishida; Alvaro Sepúlveda-Martínez; Daniel Ryd; Johannes Sperling; Henrik Engblom; Eike Nagel
Journal:  BMC Med Imaging       Date:  2017-05-17       Impact factor: 1.930

  6 in total