Literature DB >> 23023073

Markov random field and Gaussian mixture for segmented MRI-based partial volume correction in PET.

Alexandre Bousse1, Stefano Pedemonte, Benjamin A Thomas, Kjell Erlandsson, Sébastien Ourselin, Simon Arridge, Brian F Hutton.   

Abstract

In this paper we propose a segmented magnetic resonance imaging (MRI) prior-based maximum penalized likelihood deconvolution technique for positron emission tomography (PET) images. The model assumes the existence of activity classes that behave like a hidden Markov random field (MRF) driven by the segmented MRI. We utilize a mean field approximation to compute the likelihood of the MRF. We tested our method on both simulated and clinical data (brain PET) and compared our results with PET images corrected with the re-blurred Van Cittert (VC) algorithm, the simplified Guven (SG) algorithm and the region-based voxel-wise (RBV) technique. We demonstrated our algorithm outperforms the VC algorithm and outperforms SG and RBV corrections when the segmented MRI is inconsistent (e.g. mis-segmentation, lesions, etc) with the PET image.

Mesh:

Substances:

Year:  2012        PMID: 23023073     DOI: 10.1088/0031-9155/57/20/6681

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Super-Resolution PET Imaging Using Convolutional Neural Networks.

Authors:  Tzu-An Song; Samadrita Roy Chowdhury; Fan Yang; Joyita Dutta
Journal:  IEEE Trans Comput Imaging       Date:  2020-01-06

2.  PET Image Deblurring and Super-Resolution with an MR-Based Joint Entropy Prior.

Authors:  Tzu-An Song; Fan Yang; Samadrita Roy Chowdhury; Kyungsang Kim; Keith A Johnson; Georges El Fakhri; Quanzheng Li; Joyita Dutta
Journal:  IEEE Trans Comput Imaging       Date:  2019-04-25

3.  Partial volume correction in quantitative amyloid imaging.

Authors:  Yi Su; Tyler M Blazey; Abraham Z Snyder; Marcus E Raichle; Daniel S Marcus; Beau M Ances; Randall J Bateman; Nigel J Cairns; Patricia Aldea; Lisa Cash; Jon J Christensen; Karl Friedrichsen; Russ C Hornbeck; Angela M Farrar; Christopher J Owen; Richard Mayeux; Adam M Brickman; William Klunk; Julie C Price; Paul M Thompson; Bernadino Ghetti; Andrew J Saykin; Reisa A Sperling; Keith A Johnson; Peter R Schofield; Virginia Buckles; John C Morris; Tammie L S Benzinger
Journal:  Neuroimage       Date:  2014-12-05       Impact factor: 6.556

4.  Cerebral blood flow with [15O]water PET studies using an image-derived input function and MR-defined carotid centerlines.

Authors:  Edward K Fung; Richard E Carson
Journal:  Phys Med Biol       Date:  2013-02-27       Impact factor: 3.609

Review 5.  MRI-Driven PET Image Optimization for Neurological Applications.

Authors:  Yuankai Zhu; Xiaohua Zhu
Journal:  Front Neurosci       Date:  2019-07-31       Impact factor: 4.677

6.  Decreased Functional Connectivity of Vermis-Ventral Prefrontal Cortex in Bipolar Disorder.

Authors:  Huanhuan Li; Hu Liu; Yanqing Tang; Rongkai Yan; Xiaowei Jiang; Guoguang Fan; Wenge Sun
Journal:  Front Hum Neurosci       Date:  2021-07-16       Impact factor: 3.473

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.