Literature DB >> 23020963

The best conditions for parallel stenting during EVAR: an in vitro study.

G Mestres1, J P Uribe, C García-Madrid, E Miret, X Alomar, M Burrell, V Riambau.   

Abstract

OBJECTIVES: The aim of this study is to identify which endograft, and to what degree of oversizing, in combination with what type of parallel stent, may result in the most adequate fit in a juxtarenal abdominal aneurysmal neck when using a parallel-stent technique. MATERIALS/
METHODS: In-vitro silicon aneurysmal neck models of different diameters, with one side-branch, were constructed. Two different endografts (Medtronic-Endurant Abdominal Stent Graft and Gore-Excluder abdominal aortic aneurysm Endoprosthesis; three diameters each), and two stents (self-expanding Gore Viabahn Endoprosthesis and balloon-expandable Atrium Advanta V12; 6-mm diameter) were tested, applying three endograft-oversizing degrees (15%, 30% and 40%). After remodelling using the kissing-balloon technique at 37 °C, the 36 endograft-stent-oversizing combinations were scanned by computed tomography (CT). The size of the results in gutters, parallel-stent compression and main stent-graft infolding were recorded.
RESULTS: Increasing oversizing (15%, 30% and 40%) significantly decreased gutter areas (11.5, 6.2, 4.3 mm(2), P < 0.001); nevertheless, main endograft infolding of most 40%-oversized stent grafts was detected, particularly with Excluder devices. Lower stent compression, but wider gutters, were observed with the Excluder when compared to Endurant stent grafts, and with V12 when compared to Viabahn parallel stents. The Endurant-Viabahn combination resulted in maximum stent compression (35%).
CONCLUSIONS: Better endograft-stent apposition was achieved when using 30% endograft oversizing. Lower stent compression, but wider gutters, were observed with the Excluder stent-graft and V12 parallel stent, achieving maximum stent compression with the Endurant-Viabahn combination.
Copyright © 2012 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23020963     DOI: 10.1016/j.ejvs.2012.08.007

Source DB:  PubMed          Journal:  Eur J Vasc Endovasc Surg        ISSN: 1078-5884            Impact factor:   7.069


  10 in total

1.  Deployment of stent graft in an excessively higher position above the renal artery induces a flow channel to the aneurysm in chimney endovascular aortic aneurysm repair: an in vitro study.

Authors:  Kota Shukuzawa; Taku Akaoka; Mitsuo Umezu; Takao Ohki; Kiyotaka Iwasaki
Journal:  J Artif Organs       Date:  2019-01-20       Impact factor: 1.731

2.  Natural history of gutter-related type Ia endoleaks after snorkel/chimney endovascular aneurysm repair.

Authors:  Brant W Ullery; Kenneth Tran; Nathan K Itoga; Ronald L Dalman; Jason T Lee
Journal:  J Vasc Surg       Date:  2017-02-08       Impact factor: 4.268

Review 3.  Review of Treatment for Thoracoabdominal Aortic Aneurysm, and the Modern Experience of Multi-Branched Endograft in Taiwan.

Authors:  Ting Chao Lin; Chun Che Shih
Journal:  Acta Cardiol Sin       Date:  2017-01       Impact factor: 2.672

Review 4.  Advanced Endovascular Approaches in the Management of Challenging Proximal Aortic Neck Anatomy: Traditional Endografts and the Snorkel Technique.

Authors:  Jon G Quatromoni; Ksenia Orlova; Paul J Foley
Journal:  Semin Intervent Radiol       Date:  2015-09       Impact factor: 1.513

Review 5.  Fenestrated and Chimney Technique for Juxtarenal Aortic Aneurysm: A Systematic Review and Pooled Data Analysis.

Authors:  Yue Li; Zhongzhou Hu; Chujie Bai; Jie Liu; Tao Zhang; Yangyang Ge; Shaoliang Luan; Wei Guo
Journal:  Sci Rep       Date:  2016-02-12       Impact factor: 4.379

6.  Successful Management of a Type B Gutter Related Endoleak after Chimney EVAR by Coil Assisted Onyx Embolisation.

Authors:  Marta Ballesteros-Pomar; Gergana T Taneva; Martin Austermann; Rafael Fernández-Samos; Giovanni Torsello; Konstantinos P Donas
Journal:  EJVES Short Rep       Date:  2019-01-24

7.  Gutter Characteristics and Stent Compression of Self-Expanding vs Balloon-Expandable Chimney Grafts in Juxtarenal Aneurysm Models.

Authors:  Jorn P Meekel; Theodorus G van Schaik; Rutger J Lely; Gerie Groot; Bram B van der Meijs; Willem Wisselink; Jan D Blankensteijn; Kak K Yeung
Journal:  J Endovasc Ther       Date:  2020-04-21       Impact factor: 3.487

8.  Endovascular treatment of a tuberculous aneurysm of the pararenal abdominal aorta leading to an aortoduodenal fistula.

Authors:  Shuhei Azuma; Shinji Fukuhara; Yoshii Yasuyoshi
Journal:  J Vasc Surg Cases Innov Tech       Date:  2022-08-06

Review 9.  Thoracoabdominal aortic aneurysm repair: current endovascular perspectives.

Authors:  Nathan Orr; David Minion; Joseph L Bobadilla
Journal:  Vasc Health Risk Manag       Date:  2014-08-19

Review 10.  Fenestrated Endovascular Aneurysm Repair versus Snorkel Endovascular Aneurysm Repair: Competing yet Complementary Strategies.

Authors:  William J Yoon
Journal:  Vasc Specialist Int       Date:  2019-09-30
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.