Literature DB >> 23015080

Band analysis of hydrated human skin stratum corneum attenuated total reflectance fourier transform infrared spectra in vivo.

G W Lucassen, G N van Veen, J A Jansen.   

Abstract

Water content is an important factor for skin condition. The determination of the hydration state of the skin is necessary to obtain basic knowledge about the penetration and loss of water in the skin stratum corneum. Attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy is used to measure hydration of the stratum corneum. In this study we apply direct band fitting of the water bending, combination, and OH stretch bands over the 4000-650 cm-1 wave number range. Measurements are performed on the volar aspect of the forearm using a Nicolet 800 FTIR spectrometer equipped with an ATR unit with a ZnSe crystal. Hydration of the skin is obtained by occlusion keeping the forearm pressed onto the crystal. Spectra are recorded before and after occlusion up to 30 min. The spectra are fitted with a nonlinear least-squares algorithm with Gaussian bands. Separate band fits of water, normal stratum corneum, and occluded hydrated stratum corneum spectra are obtained yielding band parameters of the individual water contributions in the bending mode at 1640 cm-1, the combination band at 2125 cm-1, and the OH stretches in the hydrated skin stratum corneum spectra. A scaling factor representing the contribution of the water spectrum into the skin stratum corneum spectrum is determined during the occlusion process. In comparison to the dependence of the infrared absorbance ratio in time used by Potts, our scaling factor shows a more distinct transition from enhanced signal due to increased contact area to extra signal due to water content at maximum contact area. Band fit analysis of hydrated skin stratum corneum ATR-FTIR spectra offers the possibility for quantitative determination of individual water band parameters. © 1998 Society of Photo-Optical Instrumentation Engineers.

Entities:  

Year:  1998        PMID: 23015080     DOI: 10.1117/1.429890

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  12 in total

1.  Detection of endogenous biomolecules in Barrett's esophagus by Fourier transform infrared spectroscopy.

Authors:  Thomas D Wang; George Triadafilopoulos; James M Crawford; Lisa R Dixon; Tarun Bhandari; Peyman Sahbaie; Shai Friedland; Roy Soetikno; Christopher H Contag
Journal:  Proc Natl Acad Sci U S A       Date:  2007-09-27       Impact factor: 11.205

2.  Q-r curve of thermal tomography and its clinical application on breast tumor diagnosis.

Authors:  Guilian Shi; Fei Han; Lin Wang; Chengwen Liang; Kaiyang Li
Journal:  Biomed Opt Express       Date:  2015-03-03       Impact factor: 3.732

3.  Solar UV radiation reduces the barrier function of human skin.

Authors:  Krysta Biniek; Kemal Levi; Reinhold H Dauskardt
Journal:  Proc Natl Acad Sci U S A       Date:  2012-10-01       Impact factor: 11.205

4.  In vitro glucose measurement using tunable mid-infrared laser spectroscopy combined with fiber-optic sensor.

Authors:  Songlin Yu; Dachao Li; Hao Chong; Changyue Sun; Haixia Yu; Kexin Xu
Journal:  Biomed Opt Express       Date:  2013-12-17       Impact factor: 3.732

5.  Vibrational spectroscopy of muscular tissue intoxicated by snake venom and exposed to photobiomodulation therapy.

Authors:  Willians Fernando Vieira; Bruno Kenzo-Kagawa; Maria Helena Mesquita Britto; Helder José Ceragioli; Kumiko Koibuchi Sakane; Vitor Baranauskas; Maria Alice da Cruz-Höfling
Journal:  Lasers Med Sci       Date:  2017-11-28       Impact factor: 3.161

Review 6.  Imaging and quantifying drug delivery in skin - Part 2: Fluorescence andvibrational spectroscopic imaging methods.

Authors:  Ana-Maria Pena; Xueqin Chen; Isaac J Pence; Thomas Bornschlögl; Sinyoung Jeong; Sébastien Grégoire; Gustavo S Luengo; Philippe Hallegot; Peyman Obeidy; Amin Feizpour; Kin F Chan; Conor L Evans
Journal:  Adv Drug Deliv Rev       Date:  2020-03-23       Impact factor: 15.470

7.  Use of an endoscope-compatible probe to detect colonic dysplasia with Fourier transform infrared spectroscopy.

Authors:  Mark A Mackanos; John Hargrove; Rolf Wolters; Christine B Du; Shai Friedland; Roy M Soetikno; Christopher H Contag; May R Arroyo; James M Crawford; Thomas D Wang
Journal:  J Biomed Opt       Date:  2009 Jul-Aug       Impact factor: 3.170

8.  Mid-Infrared Photoacoustic Detection of Glucose in Human Skin: Towards Non-Invasive Diagnostics.

Authors:  Jonas Kottmann; Julien M Rey; Markus W Sigrist
Journal:  Sensors (Basel)       Date:  2016-10-10       Impact factor: 3.576

9.  Glucose sensing in human epidermis using mid-infrared photoacoustic detection.

Authors:  Jonas Kottmann; Julien M Rey; Joachim Luginbühl; Ernst Reichmann; Markus W Sigrist
Journal:  Biomed Opt Express       Date:  2012-03-01       Impact factor: 3.732

10.  Mid-infrared fiber-coupled photoacoustic sensor for biomedical applications.

Authors:  Jonas Kottmann; Urs Grob; Julien M Rey; Markus W Sigrist
Journal:  Sensors (Basel)       Date:  2013-01-02       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.