Literature DB >> 23010908

Micro-CT features of intermediate gunshot wounds severely damaged by fire.

Paolo Fais1, Chiara Giraudo, Rafael Boscolo-Berto, Alessandro Amagliani, Diego Miotto, Giampietro Feltrin, Guido Viel, S Davide Ferrara, Giovanni Cecchetto.   

Abstract

Incineration or extensive burning of the body, causing changes in the content and distribution of fluids, fixation and shrinking processes of tissues, can alter the typical macroscopic and microscopic characteristics of firearm wounds, hampering or at least complicating the reconstruction of gunshot fatalities. The present study aims at evaluating the potential role of micro-computed tomography (micro-CT) for detecting and quantifying gunshot residue (GSR) particles in experimentally produced intermediate-range gunshot wounds severely damaged by fire. Eighteen experimental shootings were performed on 18 sections of human calves surgically amputated for medical reasons at three different firing distances (5, 15 and 30 cm). Six stab wounds produced with an ice pick were used as controls. Each calf section underwent a charring cycle, being placed in a wood-burning stove for 4 min at a temperature of 400 °C. At visual inspection, the charred entrance wounds could not be differentiated from the exit lesions and the stab wounds. On the contrary, micro-CT analysis showed the presence of GSR particles in all burnt entrance gunshot wounds, while GSR was absent in the exit and stab wounds. The GSR deposits of the firearm lesions inflicted at very close distance (5 cm) were mainly constituted of huge particles (diameter >150 μm) with an irregular shape and well-delineated edges; at greater distances (15 and 30 cm), agglomerates of tiny radiopaque particles scattered in the epidermis and dermis layers were evident. Statistical analysis demonstrated that also in charred firearm wounds the amount of GSR roughly correlates with the distance from which the gun was fired. The obtained results suggest that micro-CT analysis can be a valid screening tool for identifying entrance gunshot wounds and for differentiating firearm wounds from sharp-force injuries in bodies severely damaged by fire.

Entities:  

Mesh:

Year:  2012        PMID: 23010908     DOI: 10.1007/s00414-012-0775-6

Source DB:  PubMed          Journal:  Int J Legal Med        ISSN: 0937-9827            Impact factor:   2.686


  26 in total

1.  Detection of gunshot residues in routine CTs.

Authors:  K M Stein; M L Bahner; J Merkel; S Ain; R Mattern
Journal:  Int J Legal Med       Date:  2000       Impact factor: 2.686

2.  Thermally induced entrance wound-like defect of the skull.

Authors:  R Hausmann; P Betz
Journal:  Forensic Sci Int       Date:  2002-08-28       Impact factor: 2.395

3.  The survival of metallic residues from gunshot wounds in cremated bone: a radiological study.

Authors:  Alberto Amadasi; Simone Borgonovo; Alberto Brandone; Mauro Di Giancamillo; Cristina Cattaneo
Journal:  Int J Legal Med       Date:  2011-10-27       Impact factor: 2.686

Review 4.  Two-gun suicide by simultaneous shots to the head: interdisciplinary reconstruction on the basis of scene investigation, autopsy findings, GSR analysis and examination of firearms, bullets and cartridge cases.

Authors:  Markus Grosse Perdekamp; Hadi Nadjem; Joachim Merkel; Roland Braunwarth; Stefan Pollak; Annette Thierauf
Journal:  Int J Legal Med       Date:  2010-10-10       Impact factor: 2.686

5.  Tissue defect at the gunshot entrance wound: what happens to the skin?

Authors:  M Grosse Perdekamp; B Vennemann; D Mattern; A Serr; S Pollak
Journal:  Int J Legal Med       Date:  2005-04-16       Impact factor: 2.686

6.  Suicide with associated acts of arson: two cases from Colorado.

Authors:  Thomas W Adair; Angela Fisher
Journal:  J Forensic Sci       Date:  2006-07       Impact factor: 1.832

7.  The role of computed tomography in terminal ballistic analysis.

Authors:  G N Rutty; P Boyce; C E Robinson; A J Jeffery; B Morgan
Journal:  Int J Legal Med       Date:  2007-01-05       Impact factor: 2.686

8.  Virtual histology by means of high-resolution X-ray CT.

Authors:  V Cnudde; B Masschaele; H E V De Cock; K Olstad; L Vlaminck; J Vlassenbroeck; M Dierick; Y D Witte; L Van Hoorebeke; P Jacobs
Journal:  J Microsc       Date:  2008-12       Impact factor: 1.758

Review 9.  The forensic evaluation of burned skeletal remains: a synthesis.

Authors:  Douglas H Ubelaker
Journal:  Forensic Sci Int       Date:  2008-11-17       Impact factor: 2.395

10.  Planned complex suicide. Report of two autopsy cases of suicidal shot injury and subsequent self-immolation.

Authors:  E E Türk; S Anders; M Tsokos
Journal:  Forensic Sci Int       Date:  2004-01-06       Impact factor: 2.395

View more
  4 in total

Review 1.  Early clinical applications for imaging at microscopic detail: microfocus computed tomography (micro-CT).

Authors:  J Ciaran Hutchinson; Susan C Shelmerdine; Ian C Simcock; Neil J Sebire; Owen J Arthurs
Journal:  Br J Radiol       Date:  2017-05-04       Impact factor: 3.039

Review 2.  Back to the Future - Part 2. Post-mortem assessment and evolutionary role of the bio-medicolegal sciences.

Authors:  Santo Davide Ferrara; Giovanni Cecchetto; Rossana Cecchi; Donata Favretto; Silke Grabherr; Takaki Ishikawa; Toshikazu Kondo; Massimo Montisci; Heidi Pfeiffer; Maurizio Rippa Bonati; Dina Shokry; Marielle Vennemann; Thomas Bajanowski
Journal:  Int J Legal Med       Date:  2017-04-25       Impact factor: 2.686

3.  Micro-CT features of intermediate gunshot wounds covered by textiles.

Authors:  Chiara Giraudo; Paolo Fais; Guido Pelletti; Alessia Viero; Diego Miotto; Rafael Boscolo-Berto; Guido Viel; Massimo Montisci; Giovanni Cecchetto; Santo Davide Ferrara
Journal:  Int J Legal Med       Date:  2016-06-20       Impact factor: 2.686

4.  Homicide and concealment of the corpse. Autopsy case series and review of the literature.

Authors:  Maria De Matteis; Arianna Giorgetti; Guido Viel; Chiara Giraudo; Claudio Terranova; Amalia Lupi; Paolo Fais; Alessandra Puggioni; Giovanni Cecchetto; Massimo Montisci
Journal:  Int J Legal Med       Date:  2020-05-30       Impact factor: 2.686

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.