Literature DB >> 11197621

Detection of gunshot residues in routine CTs.

K M Stein1, M L Bahner, J Merkel, S Ain, R Mattern.   

Abstract

The forensic assessment of non-fatal gunshot wounds often proves to be difficult as wounds have usually been cleaned and protected with a sterile bandage by the time of the examination. The aim of our investigation was to test the possible application of computed tomography (CT) for the forensic assessment. Doing so raised the questions whether gunshot residues in the soft tissues, detected by means of 3-dimensional CT, can be used as evidence of a close-range shot and whether conclusions can be drawn pertaining to the range of the shot or the type of bullet used based on the distribution of the radiologically detectable material? In this experimental study 39 shots were fired at fresh pig skin and it was possible to distinguish shots fired from distances of more than 10 cm and contact shots independent of the type of bullet. For unjacketed lead bullets, radiopaque material could be seen in the depth of the entrance would for firing distances up to 10 cm. In individual cases, CT data and the 3-D reconstruction could provide valuable information in the forensic assessment of patients with gunshot wounds.

Entities:  

Mesh:

Year:  2000        PMID: 11197621     DOI: 10.1007/s004149900124

Source DB:  PubMed          Journal:  Int J Legal Med        ISSN: 0937-9827            Impact factor:   2.686


  21 in total

1.  Detachment of the periosteum and soot staining of its underside in contact shots to the cerebral cranium.

Authors:  M Faller-Marquardt; M Bohnert; S Pollak
Journal:  Int J Legal Med       Date:  2004-09-29       Impact factor: 2.686

2.  The survival of metallic residues from gunshot wounds in cremated bone: a radiological study.

Authors:  Alberto Amadasi; Simone Borgonovo; Alberto Brandone; Mauro Di Giancamillo; Cristina Cattaneo
Journal:  Int J Legal Med       Date:  2011-10-27       Impact factor: 2.686

3.  MicroCT detection of gunshot residue in fresh and decomposed firearm wounds.

Authors:  Giovanni Cecchetto; Alessandro Amagliani; Chiara Giraudo; Paolo Fais; Fabiano Cavarzeran; Massimo Montisci; Giampietro Feltrin; Guido Viel; Santo Davide Ferrara
Journal:  Int J Legal Med       Date:  2011-11-16       Impact factor: 2.686

4.  Secondary skull fractures in head wounds inflicted by captive bolt guns: autopsy findings and experimental simulation.

Authors:  Markus Grosse Perdekamp; Beat P Kneubuehl; Takaki Ishikawa; Hadi Nadjem; Jan Kromeier; Stefan Pollak; Annette Thierauf
Journal:  Int J Legal Med       Date:  2010-11       Impact factor: 2.686

5.  Estimation of the firing distance through micro-CT analysis of gunshot wounds.

Authors:  Giovanni Cecchetto; Chiara Giraudo; Alessandro Amagliani; Guido Viel; Paolo Fais; Fabiano Cavarzeran; Giampietro Feltrin; Santo Davide Ferrara; Massimo Montisci
Journal:  Int J Legal Med       Date:  2010-12-01       Impact factor: 2.686

6.  GSR deposition along the bullet path in contact shots to composite models.

Authors:  Markus Grosse Perdekamp; Max Arnold; Joachim Merkel; Katrin Mierdel; Roland Braunwarth; Beat P Kneubuehl; Stefan Pollak; Annette Thierauf
Journal:  Int J Legal Med       Date:  2010-11-19       Impact factor: 2.686

7.  Diagnostic and therapeutic aspects in the treatment of gunshot wounds of the viscerocranium.

Authors:  A Gröbe; J Klatt; M Heiland; R Schmelzle; P Pohlenz
Journal:  Eur J Trauma Emerg Surg       Date:  2010-05-11       Impact factor: 3.693

8.  Does imaging technology overcome problems of conventional postmortem examination? A trial of computed tomography imaging for postmortem examination.

Authors:  Mutsumi Hayakawa; Seiji Yamamoto; Hisako Motani; Daisuke Yajima; Yayoi Sato; Hirotaro Iwase
Journal:  Int J Legal Med       Date:  2005-10-12       Impact factor: 2.686

9.  Tissue defect at the gunshot entrance wound: what happens to the skin?

Authors:  M Grosse Perdekamp; B Vennemann; D Mattern; A Serr; S Pollak
Journal:  Int J Legal Med       Date:  2005-04-16       Impact factor: 2.686

Review 10.  [Forensic radiology].

Authors:  K M Stein; K Grünberg
Journal:  Radiologe       Date:  2009-01       Impact factor: 0.635

View more