Literature DB >> 23000588

Contrast-enhanced ultrasound analysis of renal perfusion in normal micropigs.

Kangjae Yi1, Seoyeoun Ji, Junyoung Kim, Junghee Yoon, Mincheol Choi.   

Abstract

Contrast-enhanced ultrasound is one of method for evaluating renal perfusion. The purpose of this project was to assess perfusion patterns and dynamics in normal micropig kidney using ultrasonographic contrast media. Eight young healthy micropigs were included in this study. Micropigs were anesthetized with propofol and received an intravenous bolus of microbubble contrast media through an ear vein. Time/mean pixel value (MPV) curves were generated for selected regions in the right renal cortex and medulla. The parenchyma was enhanced in two phases. The cortex was first enhanced followed by a more gradual enhancement of the medulla. A significant difference in perfusion was detected between the cortex and medulla. Following the bolus injection, the average upslope was 0.68 ± 0.27 MPV/sec, downslope was -0.27 ± 0.13 MPV/sec, baseline was 73.9 ± 16.5 MPV, peak was 84.6 ± 17.2 MPV, and time-to-peak (from injection) was 17.5 ± 6.6 sec for the cortex. For the medulla, the average upslope was 0.50 ± 0.24 MPV/sec, downslope was -0.12 ± 0.06 MPV/sec, baseline was 52.7 ± 7.0 MPV, peak was 65.2 ± 9.3 MPV, and time-to-peak (from injection) was 27.5 ± 5.0 sec. These data can be used as normal reference values for studying young micropigs.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23000588      PMCID: PMC3467407          DOI: 10.4142/jvs.2012.13.3.311

Source DB:  PubMed          Journal:  J Vet Sci        ISSN: 1229-845X            Impact factor:   1.672


  17 in total

Review 1.  Physiology of the renal medullary microcirculation.

Authors:  Thomas L Pallone; Zhong Zhang; Kristie Rhinehart
Journal:  Am J Physiol Renal Physiol       Date:  2003-02

2.  Contrast harmonic ultrasound of spontaneous liver nodules in 32 dogs.

Authors:  R T O'Brien; M Iani; J Matheson; F Delaney; K Young
Journal:  Vet Radiol Ultrasound       Date:  2004 Nov-Dec       Impact factor: 1.363

3.  Use of the galactose-based contrast agent SHU 508A (Levovist) in renal ultrasonography of the dog.

Authors:  M Pietra; E Brini; F Fracassi; A Diana; M Cipone
Journal:  Vet Res Commun       Date:  2005-08       Impact factor: 2.459

4.  The effect of the sample size and location on contrast ultrasound measurement of perfusion parameters.

Authors:  Merja R Leinonen; Marja R Raekallio; Outi M Vainio; Mirja O Ruohoniemi; Robert T O'Brien
Journal:  Vet Radiol Ultrasound       Date:  2011 Jan-Feb       Impact factor: 1.363

5.  The behavior of sonicated albumin microbubbles within the microcirculation: a basis for their use during myocardial contrast echocardiography.

Authors:  M W Keller; S S Segal; S Kaul; B Duling
Journal:  Circ Res       Date:  1989-08       Impact factor: 17.367

6.  In vivo myocardial kinetics of air-filled albumin microbubbles during myocardial contrast echocardiography. Comparison with radiolabeled red blood cells.

Authors:  A R Jayaweera; N Edwards; W P Glasheen; F S Villanueva; R D Abbott; S Kaul
Journal:  Circ Res       Date:  1994-06       Impact factor: 17.367

7.  Detection of parenchymal abnormalities in acute pyelonephritis by pulse inversion harmonic imaging with or without microbubble ultrasonographic contrast agent: correlation with computed tomography.

Authors:  B Kim; H K Lim; M H Choi; J Y Woo; J Ryu; S Kim; K R Peck
Journal:  J Ultrasound Med       Date:  2001-01       Impact factor: 2.153

8.  Contrast-enhanced ultrasonography in normal canine liver. Evaluation of imaging and safety parameters.

Authors:  Helena T Nyman; Annemarie T Kristensen; Mads Kjelgaard-Hansen; Fintan J McEvoy
Journal:  Vet Radiol Ultrasound       Date:  2005 May-Jun       Impact factor: 1.363

9.  Renal blood flow in pigs: changes depicted with contrast-enhanced harmonic US imaging during acute urinary obstruction.

Authors:  M Claudon; C E Barnewolt; G A Taylor; P S Dunning; R Gobet; A B Badawy
Journal:  Radiology       Date:  1999-09       Impact factor: 11.105

10.  Harmonic US imaging of vesicoureteric reflux in children: usefulness of a second generation US contrast agent.

Authors:  Giorgio Ascenti; Giovanni Zimbaro; Silvio Mazziotti; Roberto Chimenz; Carmelo Fede; Carmela Visalli; Emanuele Scribano
Journal:  Pediatr Radiol       Date:  2004-04-24
View more
  3 in total

Review 1.  Contrast-enhanced ultrasound: A promising method for renal microvascular perfusion evaluation.

Authors:  Ling Wang; Chandra Mohan
Journal:  J Transl Int Med       Date:  2016-09-23

2.  Effects of high-fat diet and losartan on renal cortical blood flow using contrast ultrasound imaging.

Authors:  Anne-Emilie Declèves; Joshua J Rychak; Dan J Smith; Kumar Sharma
Journal:  Am J Physiol Renal Physiol       Date:  2013-09-18

3.  Contrast-enhanced ultrasound of both kidneys in healthy, non-anaesthetized cats.

Authors:  Hanna Schweiger; Stefanie Ohlerth; Bernhard Gerber
Journal:  Acta Vet Scand       Date:  2015-11-25       Impact factor: 1.695

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.