Literature DB >> 23000564

Stent assisted embolization of 64 anterior communicating artery aneurysms.

Andrew Kelly Johnson1, Stephan A Munich, Daniel M Heiferman, Demetrius Klee Lopes.   

Abstract

INTRODUCTION: Anterior communicating artery (ACoA) aneurysms comprised over half of the ruptured aneurysms in the International Subarachnoid Trial. Endovascular treatment of ACoA aneurysms has provided good results, but until the introduction of intracranial stents, many ACoA aneurysms could not be treated without craniotomy. The current study analyzes the results of ACoA aneurysm treatment using stent assisted embolization.
METHODS: 64 patients with ACoA aneurysms underwent stent assisted aneurysm repair. Four were treated in the acute rupture phase and a fifth ruptured aneurysm was stented in a second procedure after initial coiling. Five aneurysms were 10 mm or more in greatest diameter. Follow-up angiography was performed 6 months after treatment; then, patients were followed with annual MR angiography. Technical, clinical, and long term radiographic results were analyzed.
RESULTS: Stents were successfully deployed in each case. One patient was eventually treated with a three stent construct and died of perioperative hemorrhage. One major stroke occurred during a separate procedure when a patient was taken off antiplatelet medications. These cases were the only aneurysm related morbidity (1.6%) and mortality (1.6%) events during the entire follow-up period. After stent assisted embolization, 32 (50.0%) ACoA aneurysms were completely occluded, 15 (23.4%) had residual neck, and 17 (26.6%) had residual filling. At first radiographic follow-up, 39 of 55 (70.9%) showed complete occlusion. Three (5.5%) total aneurysms required retreatment.
CONCLUSIONS: Stent assisted aneurysm treatment was a safe and effective option in this series of ACoA aneurysms with maximum diameter less than 15 mm. ACoA aneurysms may be more likely to recur regardless of treatment option, but stent assisted embolization may be durable after stable initial radiographic follow-up.

Entities:  

Keywords:  Aneurysm; Artery; Stent

Mesh:

Substances:

Year:  2012        PMID: 23000564     DOI: 10.1136/neurintsurg-2012-010503

Source DB:  PubMed          Journal:  J Neurointerv Surg        ISSN: 1759-8478            Impact factor:   5.836


  11 in total

1.  Effect of clipping anterior communicating artery aneurysms via pterional approach contralateral to supply of dominant blood: report of 15 patients.

Authors:  Peng Liu; Li Pan; Xuefeng An; Lianting Ma; Ming Yang
Journal:  Int J Clin Exp Med       Date:  2015-02-15

Review 2.  "Coil mainly" policy in management of intracranial ACoA aneurysms: single-centre experience with the systematic review of literature and meta-analysis.

Authors:  Anna Steklacova; Ondrej Bradac; Patricia de Lacy; Jiri Lacman; Frantisek Charvat; Vladimir Benes
Journal:  Neurosurg Rev       Date:  2017-11-28       Impact factor: 3.042

3.  Stand-alone coil embolization of anterior communicating artery aneurysms: Efficacy and technical issues.

Authors:  Damian Kocur; Miłosz Zbroszczyk; Nikodem Przybyłko; Mariusz Hofman; Tomasz Jamróz; Jan Baron; Piotr Bażowski; Stanisław Kwiek
Journal:  Neuroradiol J       Date:  2016-08-16

Review 4.  Intra-procedural complications, success rate, and need for retreatment of endovascular treatments in anterior communicating artery aneurysms: a systematic review and meta-analysis.

Authors:  Pourya Yarahmadi; Ali Kabiri; Amirmohammad Bavandipour; Pascal Jabbour; Omid Yousefi
Journal:  Neurosurg Rev       Date:  2022-08-27       Impact factor: 2.800

5.  Clipping Could Be the Best Treatment Modality for Recurring Anterior Communicating Artery Aneurysms Treated Endovascularly.

Authors:  Ahmad Sweid; Kareem El Naamani; Rawad Abbas; Robert M Starke; Khodr Badih; Rayan El Hajjar; Hassan Saad; Bassel Hammoud; Carrie Andrews; Sage P Rahm; Elias Atallah; Sunidhi Ramesh; Stavropoula Tjoumakaris; M Reid Gooch; Nabeel Herial; David Hasan; Robert H Rosenwasser; Pascal Jabbour
Journal:  Neurosurgery       Date:  2022-05-01       Impact factor: 5.315

Review 6.  Endovascular treatment of anterior communicating artery aneurysms: a systematic review and meta-analysis.

Authors:  S Fang; W Brinjikji; M H Murad; D F Kallmes; H J Cloft; G Lanzino
Journal:  AJNR Am J Neuroradiol       Date:  2013-11-28       Impact factor: 3.825

7.  Stent-assisted coiling of intracranial aneurysms located on small vessels: midterm results with the LVIS Junior stent in 40 patients with 43 aneurysms.

Authors:  Faisal Alghamdi; Benjamin Mine; Ricardo Morais; Pietro Scillia; Boris Lubicz
Journal:  Neuroradiology       Date:  2016-03-05       Impact factor: 2.804

8.  How has the nationwide use of off-label experimental endovascular devices been allowed for two decades as first choice and sometimes the only alternative to conventional standard and advanced surgical techniques?

Authors:  Ramsis F Ghaly
Journal:  Surg Neurol Int       Date:  2015-02-11

Review 9.  Stent-Assisted Endovascular Treatment of Anterior Communicating Artery Aneurysms - Literature Review.

Authors:  Damian Kocur; Wojciech Ślusarczyk; Nikodem Przybyłko; Piotr Bażowski; Adam Właszczuk; Stanisław Kwiek
Journal:  Pol J Radiol       Date:  2016-08-09

Review 10.  Diagnosing flow residuals in coiled cerebral aneurysms by MR angiography: meta-analysis.

Authors:  Jan Menke; Peter Schramm; Jan Martin Sohns; Kai Kallenberg; Wieland Staab
Journal:  J Neurol       Date:  2013-07-28       Impact factor: 4.849

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.