Literature DB >> 23000118

Development of a loudness normalisation strategy for combined cochlear implant and acoustic stimulation.

Tom Francart1, Hugh J McDermott.   

Abstract

Users of a cochlear implant together with a hearing aid in the non-implanted ear currently use devices that were developed separately and are often fitted separately. This results in very different growth of loudness with level in the two ears, potentially leading to decreased wearing comfort and suboptimal perception of interaural level differences. A loudness equalisation strategy, named 'SCORE bimodal', is proposed. It equalises loudness growth for the two modalities using existing models of loudness for acoustic and electric stimulation, and is suitable for implementation in wearable devices. Loudness balancing experiments were performed with six bimodal listeners to validate the strategy. In a first set of experiments, the function of each loudness model used was validated by balancing the loudness of four harmonic complexes of different bandwidths, ranging from 200 Hz to 1000 Hz, separately for each ear. Both the electric and acoustic loudness models predicted the data well. In a second set of experiments, binaural balancing was done for the same stimuli. It was found that SCORE significantly improved binaural balance.
Copyright © 2012 Elsevier B.V. All rights reserved.

Mesh:

Year:  2012        PMID: 23000118     DOI: 10.1016/j.heares.2012.09.002

Source DB:  PubMed          Journal:  Hear Res        ISSN: 0378-5955            Impact factor:   3.208


  4 in total

Review 1.  Considerations for Fitting Cochlear Implants Bimodally and to the Single-Sided Deaf.

Authors:  Sabrina H Pieper; Noura Hamze; Stefan Brill; Sabine Hochmuth; Mats Exter; Marek Polak; Andreas Radeloff; Michael Buschermöhle; Mathias Dietz
Journal:  Trends Hear       Date:  2022 Jan-Dec       Impact factor: 3.496

2.  Modulation enhancement in the electrical signal improves perception of interaural time differences with bimodal stimulation.

Authors:  Tom Francart; Anneke Lenssen; Jan Wouters
Journal:  J Assoc Res Otolaryngol       Date:  2014-06-03

3.  Speech perception and localisation with SCORE bimodal: a loudness normalisation strategy for combined cochlear implant and hearing aid stimulation.

Authors:  Tom Francart; Hugh McDermott
Journal:  PLoS One       Date:  2012-10-24       Impact factor: 3.240

4.  Real-time loudness normalisation with combined cochlear implant and hearing aid stimulation.

Authors:  Dimitar Spirrov; Maaike Van Eeckhoutte; Lieselot Van Deun; Tom Francart
Journal:  PLoS One       Date:  2018-04-04       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.