Literature DB >> 22995480

Evaluation of high-resolution mass spectrometry for urine toxicology screening in a pain management setting.

Bridgit O Crews1, Amadeo J Pesce, Robert West, Hugh Nguyen, Robert L Fitzgerald.   

Abstract

To evaluate liquid chromatography-high-resolution mass spectrometry (LC-HR-MS) for urine toxicology screening, 29 analytes were quantitated in 152 urine specimens from patients with chronic pain using two unique mass spectrometry platforms. De-identified specimens were quantitated in April of 2011 by liquid chromatography-triple quadrupole mass spectrometry (LC-MS-MS) and by full-scan LC-HR-MS at Millennium Laboratories. Considering LC-MS-MS as the reference method, false positive results were identified in 19 specimens measured by LC-HR-MS. Application of relative retention times using deuterium labeled internal standards improved the rate of false positive detection to only five specimens, with four occurring for the same analyte. Ultra-high-resolution mass spectrometry (R = 100,000 at m/z 200) showed no improvement over high-resolution mass spectrometry (R = 10,000 at m/z 200) in the number of false positives detected. Quantitative results measured by LC-MS-MS and LC-HR-MS showed good agreement over four orders of dynamic range. This study demonstrates that LC-HR-MS is a suitable platform for toxicology screening for a pain management population and that quantitative accuracy and sensitivity are comparable to that achieved with LC-MS-MS. The specificity of LC-HR-MS is improved by the addition of deuterium labeled internal standards and the implementation of relative retention time matching.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22995480     DOI: 10.1093/jat/bks071

Source DB:  PubMed          Journal:  J Anal Toxicol        ISSN: 0146-4760            Impact factor:   3.367


  2 in total

1.  The development and validation of a method using high-resolution mass spectrometry (HRMS) for the qualitative detection of antiretroviral agents in human blood.

Authors:  Mark A Marzinke; Autumn Breaud; Teresa L Parsons; Myron S Cohen; Estelle Piwowar-Manning; Susan H Eshleman; William Clarke
Journal:  Clin Chim Acta       Date:  2014-03-22       Impact factor: 3.786

Review 2.  MS-Based Analytical Techniques: Advances in Spray-Based Methods and EI-LC-MS Applications.

Authors:  Federica Bianchi; Nicolò Riboni; Veronica Termopoli; Lucia Mendez; Isabel Medina; Leopold Ilag; Achille Cappiello; Maria Careri
Journal:  J Anal Methods Chem       Date:  2018-04-23       Impact factor: 2.193

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.