Literature DB >> 22995257

Complications of suture button ankle syndesmosis stabilization with modifications of surgical technique.

Phil Storey1, Richard J Gadd, Chris Blundell, Mark Bowen Davies.   

Abstract

BACKGROUND: The TightRope® is a relatively new device designed to stabilize ankle syndesmotic injuries. There are no studies evaluating the clinical effectiveness of this technique and few reports addressing complications and potential modifications to the surgical technique reported in this article.
MATERIALS AND METHODS: A retrospective review of 102 cases of traumatic ankle syndesmotic stabilization using the TightRope device is presented. Patients were followed up for a median of 85 days after surgery.
RESULTS: Eight patients subsequently had the TightRope removed. This was performed for four reasons: osteomyelitis surrounding the implant, painful aseptic osteolysis surrounding the implant, failed stabilization of the syndesmosis, and unexplained pain.
CONCLUSIONS: On the basis of experience, the authors recommend meticulous attention during the surgical technique. To prevent skin irritation and stitch abscess formation leading to osteomyelitis, the FiberWire loop is best cut with a knife at least 1 cm beyond the knot, allowing the sharp end of the FiberWire to lay flat adjacent to the fibula. Painful aseptic osteolytic reaction to the TightRope necessitates removal. To prevent rediastasis, a small medial incision is recommended for endobutton positioning directly abutting the tibial cortex without soft tissue interposition. Inserting the TightRope through a fibula plate prevents lateral button pull-through and rediastasis.

Entities:  

Mesh:

Year:  2012        PMID: 22995257     DOI: 10.3113/FAI.2012.0717

Source DB:  PubMed          Journal:  Foot Ankle Int        ISSN: 1071-1007            Impact factor:   2.827


  16 in total

1.  Novel anatomical reconstruction of distal tibiofibular ligaments restores syndesmotic biomechanics.

Authors:  Jian Che; Chunbao Li; Zhipeng Gao; Wei Qi; Binping Ji; Yujie Liu; Ming Han Lincoln Liow
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-03-20       Impact factor: 4.342

Review 2.  An update on the evaluation and treatment of syndesmotic injuries.

Authors:  S Rammelt; P Obruba
Journal:  Eur J Trauma Emerg Surg       Date:  2014-11-12       Impact factor: 3.693

3.  Reply to comment on Schepers: acute distal tibiofibular syndesmosis injury: a systematic review of suture-button versus syndesmotic screw repair.

Authors:  Tim Schepers
Journal:  Int Orthop       Date:  2012-11-21       Impact factor: 3.075

4.  Tightrope fixation of syndesmotic injuries in Weber C ankle fractures: a multicentre case series.

Authors:  Amarjit Anand; Ran Wei; Akash Patel; Vikas Vedi; Garth Allardice; Bobby Singh Anand
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-01-10

5.  Lower complication rate and faster return to sports in patients with acute syndesmotic rupture treated with a new knotless suture button device.

Authors:  Christian Colcuc; Marc Blank; Thomas Stein; Florian Raimann; Sanjay Weber-Spickschen; Sebastian Fischer; Reinhard Hoffmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-12-09       Impact factor: 4.342

6.  The use of TightRope fixation for ankle syndesmosis injuries: our experience.

Authors:  M Bondi; N Rossi; A Pizzoli; L Renzi Brivio
Journal:  Musculoskelet Surg       Date:  2016-08-27

7.  Syndesmosis injuries.

Authors:  Kenneth J Hunt
Journal:  Curr Rev Musculoskelet Med       Date:  2013-12

8.  A Novel Suture Button Construct for Acute Ankle Syndesmotic Injuries; A Prospective Clinical and Radiological Analysis.

Authors:  Mohamed A Imam; James Holton; Abdel Na Hassan; Ahmed Matthana
Journal:  Arch Bone Jt Surg       Date:  2018-05

9.  Flexible fixation of syndesmotic diastasis using the assembled bolt-tightrope system.

Authors:  Guohui Xu; Wei Chen; Qi Zhang; Juan Wang; Yanling Su; Yingze Zhang
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2013-09-22       Impact factor: 2.953

10.  Five-Year Outcomes After Treatment for Acute Instability of the Tibiofibular Syndesmosis Using a Suture-Button Fixation System.

Authors:  Paul F Förschner; Knut Beitzel; Andreas B Imhoff; Stefan Buchmann; Georg Feuerriegel; Felix Hofmann; Dimitrios C Karampinos; Pia Jungmann; Jonas Pogorzelski
Journal:  Orthop J Sports Med       Date:  2017-04-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.