Literature DB >> 22993044

Dynamically harmonized FT-ICR cell with specially shaped electrodes for compensation of inhomogeneity of the magnetic field. Computer simulations of the electric field and ion motion dynamics.

Yury I Kostyukevich1, Gleb N Vladimirov, Eugene N Nikolaev.   

Abstract

The recently introduced ion trap for FT-ICR mass spectrometers with dynamic harmonization showed the highest resolving power ever achieved both for ions with moderate masses 500-1000 Da (peptides) as well as ions with very high masses of up to 200 kDa (proteins). Such results were obtained for superconducting magnets of very high homogeneity of the magnetic field. For magnets with lower homogeneity, the time of transient duration would be smaller. In superconducting magnets used in FT-ICR mass spectrometry the inhomogeneity of the magnetic field in its axial direction prevails over the inhomogeneity in other directions and should be considered as the main factor influencing the synchronic motion of the ion cloud. The inhomogeneity leads to a dependence of the cyclotron frequency from the amplitude of axial oscillation in the potential well of the ion trap. As a consequence, ions in an ion cloud become dephased, which leads to signal attenuation and decrease in the resolving power. Ion cyclotron frequency is also affected by the radial component of the electric field. Hence, by appropriately adjusting the electric field one can compensate the inhomogeneity of the magnetic field and align the cyclotron frequency in the whole range of amplitudes of z-oscillations. A method of magnetic field inhomogeneity compensation in a dynamically harmonized FT-ICR cell is presented, based on adding of extra electrodes into the cell shaped in such a way that the averaged electric field created by these electrodes produces a counter force to the forces caused by the inhomogeneous magnetic field.

Mesh:

Substances:

Year:  2012        PMID: 22993044     DOI: 10.1007/s13361-012-0480-1

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  13 in total

1.  Petroleomics: the next grand challenge for chemical analysis.

Authors:  Alan G Marshall; Ryan P Rodgers
Journal:  Acc Chem Res       Date:  2004-01       Impact factor: 22.384

2.  Fourier transform ion cyclotron resonance mass resolution and dynamic range limits calculated by computer modeling of ion cloud motion.

Authors:  Gleb Vladimirov; Christopher L Hendrickson; Greg T Blakney; Alan G Marshall; Ron M A Heeren; Eugene N Nikolaev
Journal:  J Am Soc Mass Spectrom       Date:  2011-10-27       Impact factor: 3.109

3.  Fine structure in isotopic peak distributions measured using a dynamically harmonized Fourier transform ion cyclotron resonance cell at 7 T.

Authors:  Eugene N Nikolaev; Roland Jertz; Anton Grigoryev; Gökhan Baykut
Journal:  Anal Chem       Date:  2012-02-22       Impact factor: 6.986

4.  Initial experimental characterization of a new ultra-high resolution FTICR cell with dynamic harmonization.

Authors:  Eugene N Nikolaev; Ivan A Boldin; Roland Jertz; Gökhan Baykut
Journal:  J Am Soc Mass Spectrom       Date:  2011-04-19       Impact factor: 3.109

5.  Fourier transform ion cyclotron resonance cell with dynamic harmonization of the electric field in the whole volume by shaping of the excitation and detection electrode assembly.

Authors:  Ivan A Boldin; Eugene N Nikolaev
Journal:  Rapid Commun Mass Spectrom       Date:  2011-01-15       Impact factor: 2.419

6.  Atmospheric pressure ionization permanent magnet fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Andrey N Vilkov; Chaminda M Gamage; Alexander S Misharin; Vladimir M Doroshenko; Dmitry A Tolmachev; Irina A Tarasova; Oleg N Kharybin; Konstantin P Novoselov; Michael V Gorshkov
Journal:  J Am Soc Mass Spectrom       Date:  2007-05-23       Impact factor: 3.109

7.  Trapped-ion cell with improved DC potential harmonicity for FT-ICR MS.

Authors:  Aleksey V Tolmachev; Errol W Robinson; Si Wu; Hyuk Kang; Natacha M Lourette; Ljiljana Pasa-Tolić; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2008-01-31       Impact factor: 3.109

Review 8.  Fourier transform ion cyclotron resonance mass spectrometry: a primer.

Authors:  A G Marshall; C L Hendrickson; G S Jackson
Journal:  Mass Spectrom Rev       Date:  1998 Jan-Feb       Impact factor: 10.946

9.  Electrically compensated Fourier transform ion cyclotron resonance cell for complex mixture mass analysis.

Authors:  Nathan K Kaiser; Joshua J Savory; Amy M McKenna; John P Quinn; Christopher L Hendrickson; Alan G Marshall
Journal:  Anal Chem       Date:  2011-08-12       Impact factor: 6.986

10.  An electrically compensated trap designed to eighth order for FT-ICR mass spectrometry.

Authors:  Adam M Brustkern; Don L Rempel; Michael L Gross
Journal:  J Am Soc Mass Spectrom       Date:  2008-07-02       Impact factor: 3.109

View more
  15 in total

1.  From Supercomputer Modeling to Highest Mass Resolution in FT-ICR.

Authors:  Evgene N Nikolaev; Gleb N Vladimirov; Roland Jertz; Gökhan Baykut
Journal:  Mass Spectrom (Tokyo)       Date:  2013-04-15

2.  Fourier Transform Ion Cyclotron Resonance Mass Spectrometry at the Cyclotron Frequency.

Authors:  Konstantin O Nagornov; Anton N Kozhinov; Yury O Tsybin
Journal:  J Am Soc Mass Spectrom       Date:  2017-02-17       Impact factor: 3.109

3.  Application of printed circuit board technology to FT-ICR MS analyzer cell construction and prototyping.

Authors:  Franklin E Leach; Randolph Norheim; Gordon Anderson; Ljiljana Pasa-Tolic
Journal:  J Am Soc Mass Spectrom       Date:  2014-07-24       Impact factor: 3.109

4.  Twelve million resolving power on 4.7 T Fourier transform ion cyclotron resonance instrument with dynamically harmonized cell--observation of fine structure in peptide mass spectra.

Authors:  Igor A Popov; Konstantin Nagornov; Gleb N Vladimirov; Yury I Kostyukevich; Eugene N Nikolaev
Journal:  J Am Soc Mass Spectrom       Date:  2014-03-07       Impact factor: 3.109

Review 5.  Top-down proteomics in health and disease: challenges and opportunities.

Authors:  Zachery R Gregorich; Ying Ge
Journal:  Proteomics       Date:  2014-05       Impact factor: 3.984

6.  Dynamic Range Expansion by Gas-Phase Ion Fractionation and Enrichment for Imaging Mass Spectrometry.

Authors:  Boone M Prentice; Daniel J Ryan; Kerri J Grove; D Shannon Cornett; Richard M Caprioli; Jeffrey M Spraggins
Journal:  Anal Chem       Date:  2020-09-09       Impact factor: 6.986

7.  Three dimensional liquid chromatography coupling ion exchange chromatography/hydrophobic interaction chromatography/reverse phase chromatography for effective protein separation in top-down proteomics.

Authors:  Santosh G Valeja; Lichen Xiu; Zachery R Gregorich; Huseyin Guner; Song Jin; Ying Ge
Journal:  Anal Chem       Date:  2015-04-29       Impact factor: 6.986

8.  Effective top-down LC/MS+ method for assessing actin isoforms as a potential cardiac disease marker.

Authors:  Yi-Chen Chen; Serife Ayaz-Guner; Ying Peng; Nicole M Lane; Matthew Locher; Takushi Kohmoto; Lars Larsson; Richard L Moss; Ying Ge
Journal:  Anal Chem       Date:  2015-07-31       Impact factor: 6.986

Review 9.  Top-down Proteomics: Technology Advancements and Applications to Heart Diseases.

Authors:  Wenxuan Cai; Trisha M Tucholski; Zachery R Gregorich; Ying Ge
Journal:  Expert Rev Proteomics       Date:  2016-07-26       Impact factor: 3.940

Review 10.  Evaluation of major historical ICR cell designs using electric field simulations.

Authors:  Evgeny Nikolaev; Anton Lioznov
Journal:  Mass Spectrom Rev       Date:  2020-11-25       Impact factor: 9.011

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.