Capillary coated with graphene and graphene oxide sheets as stationary phase for capillary electrochromatography and capillary liquid chromatography.

Qishu Qu1, Chenhao Gu, Xiaoya Hu.   

Abstract

Graphene oxide (GO) nanosheets were immobilized onto the capillary wall using 3-aminopropyldiethoxymethyl silane as coupling agent. Graphene coated column (G@column) was fabricated by hydrazine reduction of GO modified column. Scanning electron microscopy (SEM) images provided visible evidence of the GO grafted on the capillary wall. Energy dispersive X-ray spectrometry (EDS) indicated the high coverage of the GO on the capillary wall. The G@column exhibited a pH-dependent electroosmotic flow (EOF) from anode to cathode in the pH range of 3-9 while the graphene oxide coated column (GO@column) showed a constant EOF. Both GO@column and G@column were evaluated for open-tubular capillary electrochromatography (OT-CEC). The GO@column was also evaluated for open-tubular capillary liquid chromatography (OT-CLC). Good separation of the tested neutral analytes on the GO@column was achieved on the basis of a typical reversed-phase behavior. On the contrary, G@column showed poor separation performance because of the strong π-π stacking and hydrophobic interactions between graphene and polyaromatic hydrocarbons. The high coverage of GO improved the column phase ratio which makes the GO@column promising for OT-CLC separation. Five of the major known proteins including three glycoisoforms of ovalbumin in chicken egg white were identified in a single run on the GO@column with phosphate buffer (5 mM, pH 7.0) and an applied voltage of 20 kV. The run-to-run, day-to-day, and column-to-column reproducibilities are evaluated by calculating the relative standard deviations (RSDs) of the EOF in OT-CEC and retention time of naphthalene in OT-CLC, respectively. These RSD values were found to be less than 3%.

Entities:  

Year:  2012        PMID: 22991893     DOI: 10.1021/ac3023636

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  7 in total

1.  Recent advances in the analysis of therapeutic proteins by capillary and microchip electrophoresis.

Authors:  Jessica S Creamer; Nathan J Oborny; Susan M Lunte
Journal:  Anal Methods       Date:  2014-07-08       Impact factor: 2.896

2.  Graphene oxide as a stationary phase for speciation of inorganic and organic species of mercury, arsenic and selenium using HPLC with ICP-MS detection.

Authors:  Heyong Cheng; Wenwen Zhang; Yuanchao Wang; Jinhua Liu
Journal:  Mikrochim Acta       Date:  2018-08-22       Impact factor: 5.833

3.  Maltodextrin-modified graphene oxide for improved enantiomeric separation of six basic chiral drugs by open-tubular capillary electrochromatography.

Authors:  Mingxuan Ma; Ying Xi; Yingxiang Du; Jiangxia Yang; Xiaofei Ma; Cheng Chen
Journal:  Mikrochim Acta       Date:  2019-12-17       Impact factor: 5.833

4.  Polydopamine-assisted immobilization of a zinc(II)-derived metal-organic cage as a stationary phase for open-tubular capillary electrochromatography.

Authors:  Zhentao Li; Zhenkun Mao; Zilin Chen
Journal:  Mikrochim Acta       Date:  2019-06-13       Impact factor: 5.833

5.  Gold nanoparticles coated with a tetramethylammonium lactobionate ionic liquid for enhanced chiral differentiation in open tubular capillary electrochromatography: application to enantioseparation of β-blockers.

Authors:  Xiaodong Sun; Cheng Chen; Xiaoqi Li; Yingxiang Du; Shiyuan Zhao; Zijie Feng
Journal:  Mikrochim Acta       Date:  2020-02-14       Impact factor: 5.833

6.  Enantioseparation of propranolol, amlodipine and metoprolol by electrochromatography using an open tubular capillary modified with β-cyclodextrin and poly(glycidyl methacrylate) nanoparticles.

Authors:  Xiaodong Sun; Yingxiang Du; Shiyuan Zhao; Zhifeng Huang; Zijie Feng
Journal:  Mikrochim Acta       Date:  2019-01-29       Impact factor: 5.833

7.  Determination of benzimidazoles in fruits by open-tubular capillary electrochromatography based on ionic liquids grafted covalent organic frameworks.

Authors:  Cuicui Liu; Buyi Zhao; Xiaobing Liu; Ailin Zhang
Journal:  Anal Sci       Date:  2022-07-12       Impact factor: 1.967

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.