Literature DB >> 22981614

Scheimpflug photography-based clinical characterization of the correlation of the corneal shape between the anterior and posterior corneal surfaces in the normal human eye.

Raúl Montalbán1, David P Piñero, Jaime Javaloy, Jorge L Alió.   

Abstract

PURPOSE: To evaluate the correlation of the mean curvature and shape factors between both corneal surfaces for different corneal diameters measured with a Scheimpflug photography-based system.
SETTING: Vissum Corporation, Alicante, Spain.
DESIGN: Case series.
METHODS: Randomly selected healthy normal eyes had a comprehensive ophthalmologic examination including anterior segment analysis with the Sirius system as follows: anterior and posterior mean corneal radius for 3.0 mm, 5.0 mm, and 7.0 mm; anterior and posterior mean shape factor for 4.5 mm and 8.0 mm; central (CCT) and minimum corneal thickness; and anterior chamber depth (ACD).
RESULTS: The study enrolled 117 eyes (117 subjects; aged 7 to 80 years). The mean anterior mean corneal radius:posterior mean corneal radius ratio was 1.19 (range 1.12 to 1.27) for all corneal diameters (P = .86). The correlation coefficient between the anterior and posterior mean corneal radius was 0.85 or more for all corneal diameters. The anterior mean shape factor:posterior mean shape factor ratio for the 2 corneal diameters analyzed was approximately 1 (range 0.45 to 4.03). The correlations between anterior and posterior mean shape factors were extremely poor and not significant. Multiple regression analysis showed that the central posterior mean corneal radius was significantly correlated with the anterior mean corneal radius, CCT, and spherical equivalent (R(2) = 0.77, P<.01).
CONCLUSIONS: Central posterior corneal curvature could be predicted from the anterior corneal curvature, pachymetry, and the refractive status of the eye but not from the corneal shape factor. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.
Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22981614     DOI: 10.1016/j.jcrs.2012.06.050

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  11 in total

1.  Evaluation of topographic, tomographic, topometric, densitometric, and aberrometric features of cornea with pentacam HR system in subclinical keratoconus.

Authors:  Haci Hasan Ozkan; Mustafa Koc; Hasan Kiziltoprak; Kemal Tekin; Emre Aydemir
Journal:  Int Ophthalmol       Date:  2021-03-27       Impact factor: 2.031

2.  Scheimpflug imaged corneal changes on anterior and posterior surfaces after collagen cross-linking.

Authors:  Ziad Hassan; Laszlo Modis; Eszter Szalai; Andras Berta; Gabor Nemeth
Journal:  Int J Ophthalmol       Date:  2014-04-18       Impact factor: 1.779

3.  Accuracy of corneal astigmatism correction with two Barrett Toric calculation methods.

Authors:  Jun Yang; Hong Zhang; Xiao-Tong Yang; Fang Tian; Shao-Zhen Zhao
Journal:  Int J Ophthalmol       Date:  2019-10-18       Impact factor: 1.779

4.  Surgical induced astigmatism correlated with corneal pachymetry and intraocular pressure: transconjunctival sutureless 23-gauge versus 20-gauge sutured vitrectomy in diabetes mellitus.

Authors:  Yan Shao; Li-Jie Dong; Yan Zhang; Hui Liu; Bo-Jie Hu; Ju-Ping Liu; Xiao-Rong Li
Journal:  Int J Ophthalmol       Date:  2015-06-18       Impact factor: 1.779

Review 5.  Corneal topography in keratoconus: state of the art.

Authors:  F Cavas-Martínez; E De la Cruz Sánchez; J Nieto Martínez; F J Fernández Cañavate; D G Fernández-Pacheco
Journal:  Eye Vis (Lond)       Date:  2016-02-22

6.  Preliminary validation of an optimized algorithm for intraocular lens power calculation in keratoconus.

Authors:  Vicente J Camps; David P Piñero; Esteban Caravaca; Dolores De Fez
Journal:  Indian J Ophthalmol       Date:  2017-08       Impact factor: 1.848

7.  Impact of the anterior-posterior corneal radius ratio on intraocular lens power calculation errors.

Authors:  Asato Hasegawa; Takashi Kojima; Mana Yamamoto; Yukihito Kato; Akeno Tamaoki; Kazuo Ichikawa
Journal:  Clin Ophthalmol       Date:  2018-08-27

8.  Distribution and related factors of corneal regularity and posterior corneal astigmatism in cataract patients.

Authors:  Chen Li; Jiaju Zhang; Xue Yin; Jianqing Li; Yihong Cao; Peirong Lu
Journal:  Clin Ophthalmol       Date:  2019-07-24

9.  A Comparative Study of Corneal Topography in Children with Autism Spectrum Disorder: A Cross-Sectional Study.

Authors:  Maha A ALGarzaie; Ali M Alsaqr
Journal:  Vision (Basel)       Date:  2021-01-15

10.  Accommodative Response in Patients with Central Field Loss: A Matched Case-Control Study.

Authors:  Ali Mazyed Alsaqr; Hisham AlShareef; Faisal Alhajri; Ali Abusharha; Raied Fagehi; Ahmad Alharbi; Saud Alanazi
Journal:  Vision (Basel)       Date:  2021-07-09