Literature DB >> 22977756

Retrieval of a partially degloved stent strut during percutaneous coronary intervention.

Woohyeun Kim1, Yong Hyun Kim, Sang Yup Lim, Seong Hwan Kim, Jeong Chun Ahn, Woo Hyuk Song.   

Abstract

Although stent entrapment is a rare event during percutaneous coronary intervention, stent entrapment can cause stent breakage or loss, which results in fatal complications such as stent embolism or acute myocardial infarction. We report one case of stent entrapment that was successfully treated by a snare via a contralateral transfemoral approach.

Entities:  

Keywords:  Angioplasty; Complications; Stents

Year:  2012        PMID: 22977756      PMCID: PMC3434794          DOI: 10.4068/cmj.2012.48.2.130

Source DB:  PubMed          Journal:  Chonnam Med J        ISSN: 2233-7393


  10 in total

1.  Tricks for overcoming difficult stent delivery.

Authors:  T Feldman
Journal:  Catheter Cardiovasc Interv       Date:  1999-11       Impact factor: 2.692

2.  Retrieval of dislodged and disfigured transradially delivered coronary stent: report on a case using forcep and antegrade brachial sheath insertion.

Authors:  M H Kim; K S Cha; J S Kim
Journal:  Catheter Cardiovasc Interv       Date:  2001-04       Impact factor: 2.692

3.  Intracoronary loss of balloon-mounted stents: successful retrieval with a 2 mm-"Microsnare"-device.

Authors:  M Elsner; A Peifer; W Kasper
Journal:  Cathet Cardiovasc Diagn       Date:  1996-11

4.  Nonsurgical retrieval of embolized coronary stents.

Authors:  H Eggebrecht; M Haude; C von Birgelen; O Oldenburg; D Baumgart; J Herrmann; D Welge; T Bartel; N Dagres; R Erbel
Journal:  Catheter Cardiovasc Interv       Date:  2000-12       Impact factor: 2.692

5.  Retrieval of a migrated coronary stent by means of an alligator forceps catheter.

Authors:  E Eeckhout; J C Stauffer; J J Goy
Journal:  Cathet Cardiovasc Diagn       Date:  1993-10

6.  Retrieval techniques for managing flexible intracoronary stent misplacement.

Authors:  K W Foster-Smith; K N Garratt; S T Higano; D R Holmes
Journal:  Cathet Cardiovasc Diagn       Date:  1993-09

7.  Retrieval of a lost coronary stent from the descending aorta using a PTCA balloon and biopsy forceps.

Authors:  V Berder; M Bedossa; D Gras; F Paillard; H Le Breton; J C Pony
Journal:  Cathet Cardiovasc Diagn       Date:  1993-04

8.  Angiographic and clinical outcome of intracoronary stenting: immediate and long-term results from a large single-center experience.

Authors:  J P Carrozza; R E Kuntz; M J Levine; R M Pomerantz; R F Fishman; M Mansour; C M Gibson; C C Senerchia; D J Diver; R D Safian
Journal:  J Am Coll Cardiol       Date:  1992-08       Impact factor: 24.094

9.  Four-year experience with Palmaz-Schatz stenting in coronary angioplasty complicated by dissection with threatened or present vessel closure.

Authors:  A Schömig; A Kastrati; H Mudra; R Blasini; H Schühlen; V Klauss; G Richardt; F J Neumann
Journal:  Circulation       Date:  1994-12       Impact factor: 29.690

10.  Clinical experience with the Palmaz-Schatz coronary stent. Initial results of a multicenter study.

Authors:  R A Schatz; D S Baim; M Leon; S G Ellis; S Goldberg; J W Hirshfeld; M W Cleman; H S Cabin; C Walker; J Stagg
Journal:  Circulation       Date:  1991-01       Impact factor: 29.690

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.