Literature DB >> 22977699

Percutaneous Pedicle Screw Fixation of a Hangman's Fracture Using Intraoperative, Full Rotation, Three-dimensional Image (O-arm)-based Navigation: A Technical Case Report.

Go Yoshida1, Tokumi Kanemura, Yoshimoto Ishikawa.   

Abstract

Surgical treatment of a hangman's fractures is technically demanding, even when using the standard open procedure. In this case report, a type II hangman's fracture was treated by percutaneous posterior screw fixation, without a midline incision, using intraoperative, full rotation, three-dimensional (3D) image (O-arm)-based navigation. A 48-year-old woman was injured in a motor vehicle accident and diagnosed with a unilateral hangman's fracture associated with subluxation of the C2 vertebral body on C3. After attaching the reference arc of the 3D-imaging system to the headholder, the cervical spine was screened using an O-arm without anatomical registration. Drilling and screw fixation were performed using a guide tube while referring to the reconstructed 3D-anatomical views. The operation was successfully completed without technical difficulties or neurovascular complications. This percutaneous procedure requires less dissection of normal tissue, which may allow earlier recovery. However, further validation of this procedure for its effectiveness and safety is required.

Entities:  

Keywords:  Hangman's fracture; Minimally invasive; Pedicle screw; Percutaneous; Three-dimensional image-based navigation

Year:  2012        PMID: 22977699      PMCID: PMC3429610          DOI: 10.4184/asj.2012.6.3.194

Source DB:  PubMed          Journal:  Asian Spine J        ISSN: 1976-1902


  9 in total

1.  Percutaneous screw fixation for traumatic spondylolisthesis of the axis using iso-C3D fluoroscopy-assisted navigation (case report).

Authors:  Y Sugimoto; Y Ito; T Shimokawa; Y Shiozaki; T Mazaki
Journal:  Minim Invasive Neurosurg       Date:  2010-06-08

2.  "HANGMAN'S FRACTURE" OF THE CERVICAL SPINE.

Authors:  R C SCHNEIDER; K E LIVINGSTON; A J CAVE; G HAMILTON
Journal:  J Neurosurg       Date:  1965-02       Impact factor: 5.115

3.  Clinical accuracy of three-dimensional fluoroscopy-based computer-assisted cervical pedicle screw placement: a retrospective comparative study of conventional versus computer-assisted cervical pedicle screw placement.

Authors:  Yoshimoto Ishikawa; Tokumi Kanemura; Go Yoshida; Zenya Ito; Akio Muramoto; Shuichiro Ohno
Journal:  J Neurosurg Spine       Date:  2010-11

4.  Percutaneous placement of posterior cervical screws using three-dimensional fluoroscopy.

Authors:  Langston T Holly; Kevin T Foley
Journal:  Spine (Phila Pa 1976)       Date:  2006-03-01       Impact factor: 3.468

5.  Iso-C3D fluoroscopy-based navigation in direct pedicle screw fixation of Hangman fracture: a case report.

Authors:  S Rajasekaran; S Vidyadhara; Ajoy P Shetty
Journal:  J Spinal Disord Tech       Date:  2007-12

6.  Image-guided placement of occipitocervical instrumentation using a reference arc attached to the headholder.

Authors:  Eric W Nottmeier; Phillip M Young
Journal:  Neurosurgery       Date:  2010-03       Impact factor: 4.654

7.  Morphologic characteristics of human cervical pedicles.

Authors:  E E Karaikovic; M D Daubs; R W Madsen; R W Gaines
Journal:  Spine (Phila Pa 1976)       Date:  1997-03-01       Impact factor: 3.468

8.  Intraoperative, full-rotation, three-dimensional image (O-arm)-based navigation system for cervical pedicle screw insertion.

Authors:  Yoshimoto Ishikawa; Tokumi Kanemura; Go Yoshida; Akiyuki Matsumoto; Zenya Ito; Ryoji Tauchi; Akio Muramoto; Shuichiro Ohno; Yusuke Nishimura
Journal:  J Neurosurg Spine       Date:  2011-07-15

9.  Hangman's fracture: arguments in favor of surgical therapy for type II and III according to Edwards and Levine.

Authors:  R Verheggen; J Jansen
Journal:  Surg Neurol       Date:  1998-03
  9 in total
  7 in total

Review 1.  Traumatic Spondylolisthesis of the Axis Vertebra in Adults.

Authors:  Philipp Schleicher; Matti Scholz; Andreas Pingel; Frank Kandziora
Journal:  Global Spine J       Date:  2015-04-29

2.  Treatment of Axis Ring Fractures: Recommendations of the Spine Section of the German Society for Orthopaedics and Trauma (DGOU).

Authors:  Matti Scholz; Frank Kandziora; Philipp Kobbe; S Matschke; Philipp Schleicher; Christoph Josten
Journal:  Global Spine J       Date:  2018-09-07

Review 3.  Progressively unstable c2 spondylolysis requiring spinal fusion: case report.

Authors:  Yusuke Nishimura; Michael John Ellis; Jennifer Anderson; Masahito Hara; Atsushi Natsume; Howard Joeseph Ginsberg
Journal:  Neurol Med Chir (Tokyo)       Date:  2014-02-28       Impact factor: 1.742

4.  Posterior internal fixation plus vertebral bone implantation under navigational aid for thoracolumbar fracture treatment.

Authors:  Wei Zhou; Weiqing Kong; Bizhen Zhao; Yishan Fu; Tao Zhang; Jianguang Xu
Journal:  Exp Ther Med       Date:  2013-04-29       Impact factor: 2.447

5.  Utility of a Computed Tomography-Based Navigation System (O-Arm) for En Bloc Partial Vertebrectomy for Lung Cancer Adjacent to the Thoracic Spine: Technical Case Report.

Authors:  Kazuyoshi Kobayashi; Shiro Imagama; Zenya Ito; Kei Ando; Kohei Yokoi; Naoki Ishiguro
Journal:  Asian Spine J       Date:  2016-04-15

6.  Transpedicular direct osteosynthesis of hangman's fracture from a mini-open exposure as a less invasive procedure: A technical note.

Authors:  Viktor Zsolt Kovari; Attila Josvai; Andras Csokay
Journal:  Trauma Case Rep       Date:  2017-11-06

7.  Clinical Effects of Oblique Lateral Interbody Fusion by Conventional Open versus Percutaneous Robot-Assisted Minimally Invasive Pedicle Screw Placement in Elderly Patients.

Authors:  Shuo Feng; Wei Tian; Yi Wei
Journal:  Orthop Surg       Date:  2019-12-27       Impact factor: 2.071

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.