Literature DB >> 20173564

Image-guided placement of occipitocervical instrumentation using a reference arc attached to the headholder.

Eric W Nottmeier1, Phillip M Young.   

Abstract

OBJECTIVE: To develop a safe and accurate method of image-guided placement of instrumentation in the upper cervical spine and occiput in which the reference arc is fixed to the headholder.
METHODS: The authors describe a technique for placing screws at the occipital, C1, and C2 levels using 3-dimensional image guidance in which the reference arc is fixed to the headholder. Technical details are discussed as well as modifications to the technique to maximize navigation accuracy and decrease the need for re-registration. One of 2 paired systems, the BrainLAB Vector Vision system (BrainLAB Inc., Westchester, IL) used in conjunction with the Arcadis Orbic Isocentric C-arm (Siemens Medical Solutions, Erlangen, Germany) or the Stealth Treon system (Medtronic, Littleton, MA) paired with the O-arm (Medtronic), was used for image guidance in this study. A total of 18 patients had 82 screws placed at the occipital, C1, or C2 level using this technique. An independent radiologist interpreted postoperative computed tomographic scans of these patients and graded the screws for bony breach.
RESULTS: No complications resulted from the use of image guidance or from the placement of instrumentation. Postoperative computed tomography revealed 1 screw with a minimal breach of the outer lamina of C2. Another screw was replaced intraoperatively secondary to a minimal bony breach. No other bony breach occurred.
CONCLUSIONS: This technique allows safe and accurate placement of instrumentation in the posterior occipitocervical junction using 3-dimensional image guidance in which the reference arc is attached to the headholder.

Entities:  

Mesh:

Year:  2010        PMID: 20173564     DOI: 10.1227/01.NEU.0000346264.66833.B3

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  4 in total

1.  Percutaneous Pedicle Screw Fixation of a Hangman's Fracture Using Intraoperative, Full Rotation, Three-dimensional Image (O-arm)-based Navigation: A Technical Case Report.

Authors:  Go Yoshida; Tokumi Kanemura; Yoshimoto Ishikawa
Journal:  Asian Spine J       Date:  2012-08-21

2.  Comparison of Three-Dimensional Fluoroscopy versus Postoperative Computed Tomography for the Assessment of Accurate Screw Placement after Instrumented Spine Surgery.

Authors:  Sarah T Garber; Erica F Bisson; Meic H Schmidt
Journal:  Global Spine J       Date:  2012-06

3.  Utility of a Computed Tomography-Based Navigation System (O-Arm) for En Bloc Partial Vertebrectomy for Lung Cancer Adjacent to the Thoracic Spine: Technical Case Report.

Authors:  Kazuyoshi Kobayashi; Shiro Imagama; Zenya Ito; Kei Ando; Kohei Yokoi; Naoki Ishiguro
Journal:  Asian Spine J       Date:  2016-04-15

Review 4.  Minimally Invasive Spinal Surgery with Intraoperative Image-Guided Navigation.

Authors:  Terrence T Kim; J Patrick Johnson; Robert Pashman; Doniel Drazin
Journal:  Biomed Res Int       Date:  2016-04-24       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.